{"schema_version":"1.0","country":"de","country_name":"Germany","topic":"battery-storage","question":"Where can I get a list of battery storage (BESS) installations in operation in Germany, with location, power (MW), energy (MWh), operator and commissioning date?","territory":"de","territory_level":"country","parent_url":null,"published_on":"2026-11-27","research_reviewed_on":"2026-11-26","access_checked_on":"2026-11-26","answer":{"official_data":"structured","non_official_data":"partial","summary":"The Bundesnetzagentur's Marktstammdatenregister (MaStR) is the official unit-level register of reported grid-connected battery units in Germany: status, gross/net kW, usable kWh, PLZ/Gemeinde (coordinates only above 30 kW), operator and commissioning date. Query it without login through the public viewer's JSON service or the daily XML export. On 2026-11-26, 2,929,627 battery units were In Betrieb, 556 of them above 1 MW (4.75 GW, 8.37 GWh). Rows are units: group sites by LokationMastrNr. Natural-person operators are masked.","main_caveats":["MaStR rows are units (SEE), not installations: one site can be many units (SWM Uppenborn: 10 × 2,610 kW). Group by LokationMastrNr (SEL) and sum storage rows only.","Over 99.8% of the 2.93 million operating battery units are connected at Niederspannung; there is no official grid-scale flag, so state the size or voltage filter used.","Coordinates are withheld for units ≤30 kW and for a few large anonymised units (e.g. RWE Werne, LEAG Big Battery Lausitz), which show only PLZ and place.","Natural-person operators are masked; data are self-declared and registered up to a month (sometimes more) after commissioning, so the latest weeks are incomplete.","The viewer's CSV export stops at 25,000 rows; use the JSON paging or the daily XML export."],"confidence":"high","confidence_reason":"All counts and field meanings come from live MaStR queries, the official export documentation and the MaStRV text opened on 2026-11-26; only the non-official sources stayed untested.","attributes":[{"attribute":"location","covered":"yes","source_ids":["mastr-units-api","mastr-bulk-export"],"note":"Every unit has PLZ/Ort/Gemeinde; WGS84 coordinates only for units >30 kW (§15 MaStRV): 6,646 operating units, 550 of 556 >1 MW.","gap":null,"gap_note":null},{"attribute":"power_mw","covered":"yes","source_ids":["mastr-units-api","mastr-bulk-export","bnetza-kraftwerksliste"],"note":"Bruttoleistung and Nettonennleistung in kW, discharge (Ausspeicher) side; no charging-power field for batteries. Kraftwerksliste in MW.","gap":null,"gap_note":null},{"attribute":"energy_mwh","covered":"yes","source_ids":["mastr-units-api","mastr-bulk-export"],"note":"NutzbareSpeicherkapazitaet in kWh on the linked storage object (SSE); empty for 57 operating units, filled for all 556 >1 MW.","gap":null,"gap_note":null},{"attribute":"operator","covered":"partial","source_ids":["mastr-units-api","mastr-bulk-export","bnetza-kraftwerksliste"],"note":"Operator name and ABR number for organisations; 'natürliche Person (ABR…)' for 2,851,374 operating units, incl. 19 of 556 >1 MW.","gap":"restricted","gap_note":"§15 Abs. 1 Nr. 2 MaStRV: data of natural-person operators are not published; only the masked ABR number is visible."},{"attribute":"commissioning_date","covered":"yes","source_ids":["mastr-units-api","mastr-bulk-export"],"note":"Inbetriebnahmedatum (first technical commissioning) for all operating units; registration date and date at current site are separate fields.","gap":null,"gap_note":null}]},"sources":[{"source_id":"mastr-units-api","name":"Marktstammdatenregister (MaStR) – Erweiterte öffentliche Einheitenübersicht, Stromerzeugungseinheiten (JSON grid service and CSV table export)","publisher":"Bundesnetzagentur (BNetzA)","official":true,"landing_url":"https://www.marktstammdatenregister.de/MaStR/Einheit/Einheiten/ErweiterteOeffentlicheEinheitenuebersicht","data_url":"https://www.marktstammdatenregister.de/MaStR/Einheit/EinheitJson/GetErweiterteOeffentlicheEinheitStromerzeugung","access":"api","format":"JSON (Kendo grid service, GET with filter string); CSV via the page's table export","license":"Datenlizenz Deutschland – Namensnennung – Version 2.0 (stated on the MaStR Datendownload page for the public MaStR data)","language":"de","has_coordinates":true,"location_precision":"exact","publisher_type":"regulator","adds":"Unit-level list of every registered battery storage unit with status, gross/net kW, usable kWh (joined from the storage object), PLZ/Gemeinde, WGS84 coordinates (>30 kW), operator, commissioning and registration dates; filterable, no login.","first_seen_pass":1,"rank":1,"summary":"Official, unit-level register of reported grid-connected battery units in Germany with status, kW, usable kWh, location, operator and commissioning date; queryable without login via the viewer's JSON grid service.","coverage_note":"2,929,627 battery units In Betrieb on 2026-11-26 (2,979,782 all statuses); 556 operating units >1 MW totalling 4,751 MW gross / 8,373 MWh. Coordinates only for units >30 kW.","data_date":"2026-11-26 (Datenstand 00:00 Uhr)","caveats":["Rows are units, not sites: group by LokationMastrNr.","Natural-person operators and ≤30 kW locations are masked.","CSV export capped at 25,000 rows; use JSON paging or the bulk XML."],"coverage":{"geographic":"Germany: all 16 Länder plus the Ausschließliche Wirtschaftszone (filter value), every grid level; units connected directly or indirectly to a grid must be registered."},"fine_print":{"unit":{"value":"Power (Bruttoleistung, Nettonennleistung) in kW on the discharge side of the storage unit (SEE); usable energy (NutzbareSpeicherkapazitaet) in kWh on the storage object (SSE). Divide by 1,000 for MW/MWh.","quote":"Bei Batteriespeichern ist zusätzlich eine SSE anzulegen, in der insbesondere die nutzbare Speicherkapazität (in kWh) eingetragen wird.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/regHilfen/MaStR-Datenstruktur_(Marktakteure_Einheiten_und_Gruppierungsobjekte)_final.pdf","attempts":[]},"inclusion_rule":{"value":"Every grid-connected storage unit, of any size, must be registered within one month of commissioning; only storage neither directly nor indirectly connected to a grid is exempt.","quote":"Die Pflicht zur Registrierung nach den Absätzen 1, 3 und 4 Satz 1 entfällt 1. bei Stromerzeugungseinheiten, Stromspeichern sowie EEG- und KWK-Anlagen, wenn sie weder unmittelbar noch mittelbar an ein Stromnetz angeschlossen sind oder an ein Stromnetz angeschlossen werden sollen","url":"https://www.gesetze-im-internet.de/mastrv/BJNR084210017.html","attempts":[]},"reference_date":{"value":"Viewer and JSON show the register state of the previous midnight (Datenstand 26.11.2026 00:00 Uhr on the test day); each unit carries DatumLetzteAktualisierung.","quote":"Aktuelle Einheitenübersicht Datenstand: 26.11.2026 00:00 Uhr","url":"https://www.marktstammdatenregister.de/MaStR/Einheit/Einheiten/ErweiterteOeffentlicheEinheitenuebersicht","attempts":[]},"update_frequency":{"value":"Daily; operators must report new units and changes within one month, so the most recent month is incomplete.","quote":"Registrierungen nach Absatz 1 Satz 1 müssen im Fall von Einheiten und EEG-Anlagen innerhalb eines Monats nach der Inbetriebnahme erfolgen","url":"https://www.gesetze-im-internet.de/mastrv/BJNR084210017.html","attempts":[]},"exclusions":{"value":"Street, house number, parcel and coordinates are withheld for units of at most 30 kW; operator data of natural persons are not published; KRITIS units may have data withheld.","quote":"Standortangaben zu Straße, Hausnummer, Flurstücksbezeichnungen und Geokoordinaten von Erzeugungseinheiten nach der Anlage Tabelle B bis E mit einer Leistung von höchstens 30 Kilowatt","url":"https://www.gesetze-im-internet.de/mastrv/__15.html","attempts":[]}},"key_fields":[{"field":"MaStRNummer","meaning":"Unit number of the storage unit (SEE…); one SEE per inverter/battery system as registered by the operator."},{"field":"EnergietraegerId / Stromspeichertechnologie","meaning":"2496 = Speicher; storage technology 524 = Batterie (others: Pumpspeicher 1537, Druckluft 525, Schwungrad 526, Wasserstoffspeicher 3067)."},{"field":"BetriebsStatusId / BetriebsStatusName","meaning":"35 In Betrieb, 31 In Planung, 37 Vorübergehend stillgelegt, 38 Endgültig stillgelegt."},{"field":"Bruttoleistung / Nettonennleistung","meaning":"Gross and net rated power in kW (discharge/generation side). No charging-power field exists for batteries."},{"field":"NutzbareSpeicherkapazitaet","meaning":"Usable storage capacity in kWh, taken from the linked storage object (SSE)."},{"field":"InbetriebnahmeDatum / EinheitRegistrierungsdatum","meaning":"Date of first technical commissioning of the unit vs date it was entered in the register (JSON dates as /Date(ms)/)."},{"field":"InbetriebnahmeDatumAmAktuellenOrt","meaning":"Commissioning date at the current site after a relocation; the first commissioning date is kept."},{"field":"Breitengrad / Laengengrad","meaning":"WGS84 coordinates; published only for units above 30 kW and not for units with anonymised location."},{"field":"Plz / Ort / Gemeinde / Gemeindeschluessel / Landkreis / Bundesland / StandortAnonymisiert","meaning":"Administrative location; for small units only 'PLZ Ort' in StandortAnonymisiert."},{"field":"AnlagenbetreiberName / AnlagenbetreiberMaStRNummer / AnlagenbetreiberPersonenArt","meaning":"Operator (ABR… number); natural persons (PersonenArt 518) appear as 'natürliche Person (ABR…)'."},{"field":"LokationMastrNr","meaning":"Technical generation location (SEL…): all units behind the same grid connection point(s); use it to group units into sites and detect co-located PV/wind."},{"field":"SpeicherEinheitMastrNummer / Gruppierungsobjekte","meaning":"Linked storage object (SSE…) and other grouping objects: EEG… (EEG-Anlage), SGE… (permit)."},{"field":"SpannungsebenenNamen / VollTeilEinspeisungBezeichnung","meaning":"Grid voltage level of the connection (Niederspannung = household connection) and full vs partial feed-in (self-consumption)."},{"field":"IsAnonymisiert / IsAnonymisiertNettoleistungZuHoch","meaning":"Flags set when the location is reduced to PLZ and place; the second appears on some large organisation-owned units without coordinates."}],"how_to_use":{"example_request":"https://www.marktstammdatenregister.de/MaStR/Einheit/EinheitJson/GetErweiterteOeffentlicheEinheitStromerzeugung?sort=Bruttoleistung-desc&page=1&pageSize=5&group=&filter=Energietr%C3%A4ger~eq~%272496%27~and~Speichertechnologie~eq~%27524%27~and~Betriebs-Status~eq~%2735%27~and~Bruttoleistung%20der%20Einheit~gt~%271000%27","example_result":"{\"Data\":[{\"MaStRNummer\":\"SEE916532936024\",\"EinheitName\":\"Batteriespeicher Westfalen 1\",\"AnlagenbetreiberName\":\"RWE Generation SE\",\"BetriebsStatusName\":\"In Betrieb\",\"Bruttoleistung\":174240.0,\"Nettonennleistung\":140000.0,\"NutzbareSpeicherkapazitaet\":150801.0,\"Plz\":\"59071\",\"Ort\":\"Hamm\",\"Breitengrad\":51.682563,\"Laengengrad\":7.970723,\"InbetriebnahmeDatum\":\"/Date(1735344000000)/\",…}],\"Total\":556}","steps":["Filter on Energieträger 2496 (Speicher) AND Speichertechnologie 524 (Batterie) AND Betriebs-Status 35 (In Betrieb); filter syntax is field~operator~'value' joined with ~and~ (operators eq, gt, lt, nnn = not null, nnull = null, dnull = date null), URL-encoded.","Page with page= and pageSize=; the server accepted pageSize=600 in the test (UI offers 5/10/20). 'Total' gives the denominator for the filter.","Add a size filter for grid-scale lists, e.g. Bruttoleistung der Einheit~gt~'1000' (kW) or Nutzbare Speicherkapazität in kWh~gt~'1000'; there is no official 'grid-scale' flag.","Home vs grid-scale has no official flag: use BNetzA's 'Großbatteriespeicher' convention (Bruttoleistung > 999 kW), Battery Charts classes (home <30 kWh and <30 kW; large ≥1000 kWh or ≥1000 kW) or Spannungsebene (Niederspannung = household connection). State the rule used.","Convert JSON dates /Date(ms)/ to UTC dates; kW/1000 = MW, kWh/1000 = MWh.","Group units into sites by LokationMastrNr (same grid connection), then sum kW and kWh; query 'MaStR-Nr. der Lokation~eq~'SEL…'' without the storage filter to see co-located PV/wind units.","Classify hybrid vs stand-alone: a battery whose SEL also holds solar/wind units, or with a GemeinsamRegistrierteSolareinheitMastrNummer or an EEG-Anlage link, is co-located/RE-charged; a SEL holding only storage units is stand-alone.","For >25,000 rows use this JSON service with paging or the bulk Gesamtdatenexport: the page's CSV export only contains the first 25,000 records of a selection."],"reading_traps":["Denominators (test 2026-11-26): 2,979,782 battery units registered; 2,929,627 In Betrieb; 31,619 In Planung; 1,342 vorübergehend and 17,194 endgültig stillgelegt. 2,925,580 operating units (99.86%) are connected at Niederspannung, i.e. mostly household systems.","Grid-scale denominators on 2026-11-26 (In Betrieb): 556 units >1000 kW (4,750.9 MW gross, 4,625.3 MW net, 8,373.0 MWh) on 533 SEL; 803 units >1000 kWh; 8,458 units >30 kW; 3,101 units at Mittelspannung or above.","One installation can be many SEE: SWM Uppenborn (SEL954974074669) is 10 units of 2,610 kW, BMW Leipzig 4 'Partition' units; filtering units >1 MW misses sites built from sub-1 MW units. Count sites by LokationMastrNr, not rows.","A SEL can hold hundreds of other units: Batteriespeicher Cremzow (22 MW) shares SEL946360652124 with 221 units, mostly wind turbines. Sum only storage rows for storage capacity.","Inbetriebnahmedatum is the first technical commissioning (EEG-type definition for EE-storage), not the registration date; 184 of 556 operating units >1 MW were registered more than 31 days after commissioning, 15 before it.","Coordinates exist for 6,646 of 2,929,627 operating battery units: none at ≤30 kW; 1,812 units >30 kW also lack them, including large organisation-owned units flagged IsAnonymisiertNettoleistungZuHoch (e.g. RWE Werne 72 MW, LEAG 'Big Battery Lausitz' 66 MW) that only show 'PLZ Ort'.","Operator names are masked for natural persons: 2,851,374 of 2,929,627 operating battery units, 3,046 of 8,458 units >30 kW and 19 of 556 units >1 MW show 'natürliche Person (ABR…)'.","Bruttoleistung can exceed Nettonennleistung (RWE Hamm 174,240 vs 140,000 kW); say which one is used. The power is the discharge (Ausspeicher) power; charging power is not published for batteries.","Spannungsebene can hold several values: per-level counts summed to 2,929,870, i.e. 243 more than the operating total.","Data are self-declared by operators; NetzbetreiberpruefungStatus shows whether the grid operator has checked the entry.","Stand-alone vs co-located: in a random sample of 30 of the 533 SEL hosting units >1 MW, 24 held only storage, 4 also PV, 1 natural gas, 1 biomass+PV. An EEG-Anlage link (234 of 556) means RE-only charging, not necessarily a shared SEL (e.g. 'BESS Löwenberger Land II' is alone in its SEL).","Published aggregates differ by definition and date: BNetzA (Stand 15.10.2025, >999 kW) ca. 2.4 GW gross / 3.2 GWh; SMARD (20.08.2026) 1,292 facilities at or above medium voltage, ~3.6 GW net / ~6 GWh.","MaStR and operator documents can disagree: RWE Werne is 72,000 kW / 72,000 kWh in MaStR but 79 MWh in RWE's 2023 press release."]},"test":{"tested_on":"2026-11-26","method":"api_query","http_status":200,"content_type":"application/json; charset=utf-8","size_bytes":2203037,"records_total":2979782,"records_for_country":2979782,"problems":["The page's CSV table export is capped: 'Der Tabellen-Export enthält nur die ersten 25.000 Datensätze Ihrer Auswahl.'","Operator identity withheld for natural persons; location reduced to PLZ/Ort for units ≤30 kW and for some large units flagged as anonymised.","The JSON service is the viewer's internal grid endpoint; it is not documented as an API (the documented interfaces are the XML download and a registered SOAP Webdienst)."]},"evidence":[{"claim":"Storage data structure: unit (SEE) holds discharge-side data, storage object (SSE) the usable capacity in kWh, SEL groups units at a common grid connection.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/regHilfen/MaStR-Datenstruktur_(Marktakteure_Einheiten_und_Gruppierungsobjekte)_final.pdf","quote":"Im Datenbankobjekt der zum Batteriespeicher gehörenden SEE werden die erzeugungsseitigen Daten eingetragen (z.B.: Ausspeicherleistung = Stromerzeugungsleistung)."},{"claim":"Technical location groups all units on a shared grid connection point.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/regHilfen/MaStR-Datenstruktur_(Marktakteure_Einheiten_und_Gruppierungsobjekte)_final.pdf","quote":"Die SEL umfasst alle SEE, die über einen oder mehrere gemeinsame Netzanschlusspunkte an das Stromnetz angeschlossen sind."},{"claim":"Commissioning date of a battery is entered on the storage unit and on its EEG-Anlage.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/regHilfen/Hinweise_zur_Registrierung_des_Inbetriebnahmedatums.pdf","quote":"Sowohl bei der Speicher-Einheit als auch bei der EEG-Anlage des Speichers ist das Inbetriebnahmedatum des Batteriespeichers einzutragen."},{"claim":"Natural-person operators are not published.","url":"https://www.gesetze-im-internet.de/mastrv/__15.html","quote":"Daten zu Marktakteuren nach der Anlage Tabelle A werden nicht veröffentlicht, wenn der Marktakteur eine natürliche Person ist; Daten sonstiger Marktakteure werden veröffentlicht."},{"claim":"The viewer offers usable capacity as a column.","url":"https://www.marktstammdatenregister.de/MaStR/Einheit/Einheiten/ErweiterteOeffentlicheEinheitenuebersicht","quote":"Nutzbare Speicherkapazität in kWh"},{"claim":"CSV export is limited to 25,000 rows per selection.","url":"https://www.marktstammdatenregister.de/MaStR/Shared/_DownloadInfo?fileName=Stromerzeuger&gridId=grid-stromerzeugung-erweitert","quote":"Der Tabellen-Export enthält nur die ersten 25.000 Datensätze Ihrer Auswahl."},{"claim":"BNetzA convention for grid-scale batteries.","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Speicher/artikel.html","quote":"Unter dem Begriff „Großbatteriespeicher“ bzw. „Batteriegroßspeicher“ werden üblicherweise Stromspeicher mit einer Bruttoleistung größer 999 kW zusammengefasst."}],"members":[],"members_summary":null},{"source_id":"mastr-bulk-export","name":"MaStR Gesamtdatenexport (daily full public XML export, with quarterly Stichtag snapshots)","publisher":"Bundesnetzagentur (BNetzA)","official":true,"landing_url":"https://www.marktstammdatenregister.de/MaStR/Datendownload","data_url":"https://download.marktstammdatenregister.de/Gesamtdatenexport_20261126_26.2.zip","access":"direct_download","format":"ZIP (3.3 GB) of 450 XML files in UTF-16 (68 GB uncompressed); XSD and PDF documentation in a separate ZIP","license":"Datenlizenz Deutschland – Namensnennung – Version 2.0","language":"de","has_coordinates":true,"location_precision":"exact","publisher_type":"regulator","adds":"Complete daily dump with separate tables (EinheitenStromSpeicher, AnlagenStromSpeicher, Lokationen, Marktakteure) incl. AC/DC coupling, jointly registered solar unit and Lokation membership not exposed in the viewer; quarterly snapshots since 2023 for history.","first_seen_pass":1,"rank":2,"summary":"Same official register as a daily full XML dump; needed for complete joins (unit–storage object–location–operator), AC/DC coupling and history.","coverage_note":"All public MaStR data; 30 unit files + 30 storage-object files for storage; 3.3 GB ZIP.","data_date":"2026-11-26","caveats":["3.3 GB ZIP, UTF-16 XML, 68 GB uncompressed.","Format changed on 2025-10-01."],"coverage":{"geographic":"Germany, same universe as the MaStR register (all public data)."},"fine_print":{"unit":{"value":"Bruttoleistung/Nettonennleistung in kW (EinheitenStromSpeicher); NutzbareSpeicherkapazitaet in kWh (AnlagenStromSpeicher).","quote":"NutzbareSpeicherkapazitaet                      Nutzbare                          decimal    Nein      256.784\n                                                     Speicherkapazität in kWh","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/gesamtdatenexport/Dokumentation%20MaStR%20Gesamtdatenexport.zip","attempts":[]},"inclusion_rule":{"value":"Only public data of the register; fields withheld for legal reasons are not exported.","quote":"Nicht jedes Pflichtfeld, egal welcher Art, ist im Gesamtdatenexport enthalten. Dies kann auf rechtliche Gründe wie Betriebsgeheimnisse oder Datenschutzgründe zurückzuführen sein.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/gesamtdatenexport/Dokumentation%20MaStR%20Gesamtdatenexport.zip","attempts":[]},"reference_date":{"value":"File of the day: Gesamtdatenexport_20261126_26.2.zip, Last-Modified 2026-11-26 02:36 GMT; Stichtag files on 1 Jan/Apr/Jul/Oct.","quote":"Der Datendownload wird in der Regel um 5:00 Uhr auf den zu diesem Zeitpunkt gültigen Datenstand aktualisiert.","url":"https://www.marktstammdatenregister.de/MaStR/Datendownload","attempts":[]},"update_frequency":{"value":"Daily, plus quarterly Stichtag snapshots.","quote":"Der Datendownload wird in der Regel um 5:00 Uhr auf den zu diesem Zeitpunkt gültigen Datenstand aktualisiert.","url":"https://www.marktstammdatenregister.de/MaStR/Datendownload","attempts":[]},"exclusions":{"value":"Same §15 MaStRV exclusions as the register: no street/coordinates for ≤30 kW, no natural-person operator data.","quote":"Standortangaben zu Straße, Hausnummer, Flurstücksbezeichnungen und Geokoordinaten von Erzeugungseinheiten nach der Anlage Tabelle B bis E mit einer Leistung von höchstens 30 Kilowatt","url":"https://www.gesetze-im-internet.de/mastrv/__15.html","attempts":[]}},"key_fields":[{"field":"EinheitenStromSpeicher_*.xml / EinheitStromSpeicher","meaning":"One element per storage unit (SEE) with EinheitBetriebsstatus, Technologie (524 Batterie), Bruttoleistung, Nettonennleistung, Inbetriebnahmedatum, Laengengrad/Breitengrad, AnlagenbetreiberMastrNummer, LokationMaStRNummer, SpeMastrNummer."},{"field":"AcDcKoppelung","meaning":"Katalogwert 693 = AC gekoppeltes System, 694 = DC gekoppeltes System (DC coupling implies a shared PV inverter)."},{"field":"GemeinsamRegistrierteSolareinheitMastrNummer","meaning":"Solar unit registered together with the storage ('Zum Speicher registrierte Solareinheit')."},{"field":"AnlagenStromSpeicher_*.xml: MaStRNummer, NutzbareSpeicherkapazitaet, VerknuepfteEinheitenMaStRNummern","meaning":"Storage object (SSE…) with usable kWh and the unit(s) it is linked to; join to units on SpeMastrNummer."},{"field":"Lokationen_*.xml: MastrNummer, VerknuepfteEinheitenMaStRNummern, NetzanschlusspunkteMaStRNummern","meaning":"Technical location (SEL…) with all linked units and grid connection points; basis for site grouping and stand-alone vs co-located."},{"field":"Marktakteure_*.xml","meaning":"Operator names for ABR… numbers (organisations only)."},{"field":"Katalogwerte.xml","meaning":"Decodes integer catalogue ids (status 35 In Betrieb, Energietraeger 2496 Speicher, Batterietechnologie 727 Lithium …)."}],"how_to_use":{"example_request":"curl -sI https://download.marktstammdatenregister.de/Gesamtdatenexport_20261126_26.2.zip ; curl -s -r 3313655269-3313720804 -o tail.bin <same URL>  # last 64 KB = ZIP central directory","example_result":"HTTP/1.1 200 OK, Content-Length: 3313720805, Accept-Ranges: bytes. Central directory: 450 entries, e.g. ('EinheitenStromSpeicher_30.xml', compressed 13129273, uncompressed 264220064), ('AnlagenStromSpeicher_30.xml', 2982236, 66476990), Lokationen_1..70.xml.","steps":["Download the day's ZIP from the Datendownload page (file name changes daily) and the documentation ZIP with XSDs.","Parse EinheitenStromSpeicher_1..30.xml (UTF-16) streaming; keep Technologie=524 and EinheitBetriebsstatus=35.","Join AnlagenStromSpeicher on SpeMastrNummer = MaStRNummer for NutzbareSpeicherkapazitaet (kWh).","Join Marktakteure on AnlagenbetreiberMastrNummer for operator names; join Lokationen on LokationMaStRNummer to group sites and list co-located units.","Decode ids with Katalogwerte.xml; use the Stichtag files for a time series."],"reading_traps":["Part file EinheitenStromSpeicher_30.xml alone holds 80,464 storage units (73,496 operating batteries); in it 66,474 operating batteries are DC-coupled, 6,413 AC-coupled, 609 blank, and 65,737 have a jointly registered solar unit, so most rows are PV home systems.","In AnlagenStromSpeicher_30.xml none of 80,383 storage objects links to more than one unit: a multi-container site is several SEE+SSE pairs, grouped only by SEL.","The format changed on 2025-10-01 ('neue Fassung'); scripts written for older exports may break.","Files are UTF-16 and the full archive expands to about 68 GB; stream-parse rather than load.","A third-party CSV conversion (open-MaStR on Zenodo) exists, but its latest release is the 2025-02-09 snapshot; use the BNetzA file for current data."]},"test":{"tested_on":"2026-11-26","method":"headers_only","http_status":200,"content_type":"application/x-zip-compressed","size_bytes":3313720805,"records_total":null,"records_for_country":null,"problems":[]},"evidence":[{"claim":"The export contains all public MaStR data.","url":"https://www.marktstammdatenregister.de/MaStR/Datendownload","quote":"Hier können Sie die gesamten öffentlichen Daten des Marktstammdatenregisters herunterladen."},{"claim":"Each storage unit file holds the public data of storage units.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/gesamtdatenexport/Dokumentation%20MaStR%20Gesamtdatenexport.zip","quote":"Alle öffentlichen Daten für eine Einheit der Art „StromSpeicher“."},{"claim":"AC/DC coupling and jointly registered solar unit are export fields.","url":"https://www.marktstammdatenregister.de/MaStRHilfe/files/gesamtdatenexport/Dokumentation%20MaStR%20Gesamtdatenexport.zip","quote":"GemeinsamRegistrierteSolareinheitMastrNummer   Zum      Speicher        registrierte   String    Nein   SEE91234567890"}],"members":[],"members_summary":null},{"source_id":"bnetza-kraftwerksliste","name":"Kraftwerksliste der Bundesnetzagentur (power plant list, Energieträger 'Batteriespeicher')","publisher":"Bundesnetzagentur (BNetzA)","official":true,"landing_url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/start.htm","data_url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/_DL/Kraftwerksliste_CSV.csv?__blob=publicationFile&v=11","access":"direct_download","format":"CSV (';', cp1252 despite the UTF-8 header) and XLSX","license":"unknown (not stated on the page; data drawn from the MaStR)","language":"de","has_coordinates":false,"location_precision":"none","publisher_type":"regulator","adds":"BNetzA's own site-level selection: every storage unit at a site with ≥10 MW net in total is named, with operator, status and commissioning year, in a small CSV/XLSX; smaller sites are aggregated per Land.","first_seen_pass":1,"rank":3,"summary":"Official BNetzA power-plant list; names battery units on sites ≥10 MW net with operator, status, commissioning year and MW, Bundesland only.","coverage_note":"Datenstand 05.11.2026: 214 named battery units (208 In Betrieb, 3,444.8 MW net) plus 33 Land aggregates.","data_date":"2026-11-05","caveats":["No MWh, no coordinates, commissioning year only.","cp1252 CSV with 10 preamble lines."],"coverage":{"geographic":"Germany; individual units only where the site reaches ≥10 MW net, otherwise per Bundesland aggregates."},"fine_print":{"unit":{"value":"MW (columns Bruttoleistung_MW, Nettonennleistung_MW, decimal comma); no energy (MWh) column.","quote":"Bruttoleistung_MW;Nettonennleistung_MW","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/_DL/Kraftwerksliste_CSV.csv?__blob=publicationFile&v=11","attempts":[]},"inclusion_rule":{"value":"Units are named when the site totals at least 10 MW net; others are aggregated per Land and energy carrier.","quote":"SEE Nennung: Anlagen mit einer Nettonennleistung >= 10 MW je Standort","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/_DL/Kraftwerksliste_CSV.csv?__blob=publicationFile&v=11","attempts":[]},"reference_date":{"value":"Datenstand 05.11.2026 for the file tested.","quote":"Quelle: Marktstammdatenregister Datenstand: 05.11.2026","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/_DL/Kraftwerksliste_CSV.csv?__blob=publicationFile&v=11","attempts":[]},"update_frequency":{"value":"'Regularly', no fixed interval stated.","quote":"Die Kraftwerksliste der Bundesnetzagentur und die Veröffentlichung zum Zu- und Rückbau von Kraftwerken werden regelmäßig aktualisiert.","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/start.htm","attempts":[]},"exclusions":{"value":"Sites under 10 MW net appear only as Land totals; key data are published 'unter Wahrung von Betriebs- und Geschäftsgeheimnissen'.","quote":"ohne SEE Nennung: Anlagen mit einer Nettonennleistung < 10 MW aggregiert je Bundesland und Energieträger","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/_DL/Kraftwerksliste_CSV.csv?__blob=publicationFile&v=11","attempts":[]}},"key_fields":[{"field":"EinheitMastrNummer","meaning":"MaStR unit number (SEE…); empty on Land aggregate rows. Join key to the MaStR for kWh, coordinates and dates."},{"field":"Anlagenbetreiber / Anzeigename","meaning":"Operator name and unit display name."},{"field":"Bundesland","meaning":"Only location field (written without spaces, e.g. 'SchleswigHolstein')."},{"field":"Jahr_Inbetriebnahme","meaning":"Commissioning year only."},{"field":"Kraftwerksstatus","meaning":"InBetrieb, vorläufig Stillgelegt, endgültig stillgelegt …"},{"field":"Energietraeger","meaning":"'Batteriespeicher' for batteries."},{"field":"Bruttoleistung_MW / Nettonennleistung_MW","meaning":"Gross / net power in MW."},{"field":"Spannungsebene / Anschlussnetzbetreiber","meaning":"Connection voltage level and grid operator."}],"how_to_use":{"example_request":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/_DL/Kraftwerksliste_CSV.csv?__blob=publicationFile&v=11  → decode cp1252, header on line 11, keep Energietraeger == 'Batteriespeicher' and EinheitMastrNummer starting with 'SEE'.","example_result":"SEE999790559914;EnspireME;BESS Jardelund;SchleswigHolstein;Deutschland;2018;;InBetrieb;Batteriespeicher;;Nein;Nein;48;48;Batterie;Volleinspeisung;Hochspannung;TenneT TSO GmbH (SNB970033313272);Nein;","steps":["Download the CSV (or XLSX) from the Kraftwerksliste page; the file name carries a version parameter that changes.","Decode as cp1252, split on ';', skip the 10 preamble lines (the inclusion note is a quoted multi-line cell).","Keep Energietraeger 'Batteriespeicher'; rows with EinheitMastrNummer are named units, rows without it are Land aggregates of sites <10 MW.","Convert decimal commas; join EinheitMastrNummer to the MaStR for kWh, coordinates and exact commissioning date."],"reading_traps":["Test file (Datenstand 05.11.2026): 3,113 rows, 247 battery rows, of which 214 named SEE and 33 Land aggregates; 208 named units In Betrieb = 3,444.8 MW net.","Units below 10 MW are named when their site exceeds 10 MW (e.g. 'Speicher Jerchel West - Teilanlage 3', 5.6 MW net), so rows are still units, not sites.","The aggregate rows (e.g. Bayern InBetrieb 466.11 MW net) are not a national total of all batteries; the file does not say which small units they contain.","Served as text/csv;charset=UTF-8 but encoded cp1252."]},"test":{"tested_on":"2026-11-26","method":"download","http_status":200,"content_type":"text/csv;charset=UTF-8","size_bytes":694285,"records_total":3113,"records_for_country":3113,"problems":["Declared charset UTF-8 but content is cp1252.","No storage energy (MWh) and no location below Bundesland."]},"evidence":[{"claim":"The list is built from the MaStR since 2021.","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/start.htm","quote":"Seit 2021 beruhen die Daten auf dem Marktstammdatenregister (MaStR) und werden für sämtliche Auswertungen, auch auf historisch zurückliegende, verwendet."},{"claim":"Inclusion threshold per site.","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/start.htm","quote":"Stromerzeugungseinheiten (SEE) in Deutschland mit einer elektrischen Nettonennleistung von mindestens 10 MW pro Standort"}],"members":[],"members_summary":null},{"source_id":"jrc-storage-inventory","name":"European Energy Storage Inventory – interactive map (JRC Smart Electricity Systems)","publisher":"European Commission, Joint Research Centre (JRC)","official":true,"landing_url":"https://ses.jrc.ec.europa.eu/storage-inventory-maps","data_url":null,"access":"web_viewer_only","format":"Web map; records loaded from an internal API with an obfuscated payload","license":"unknown (disclaimer: mainly public data and Wood Mackenzie data)","language":"en","has_coordinates":true,"location_precision":null,"publisher_type":"supranational","adds":"Project-level (not unit-level) map across Europe with status 'Operational', power (MW) and capacity (MWh) filters; useful to compare Germany with other countries, but most records come from Wood Mackenzie and some MWh are estimated.","first_seen_pass":1,"rank":4,"summary":"","coverage_note":"","data_date":null,"caveats":[],"coverage":{"geographic":"Europe (EU and neighbours); Germany selectable (country filter value 375)."},"fine_print":{"unit":{"value":"Power in MW and capacity in MWh (filters); some MWh estimated.","quote":"Some of the capacities (MWh) have been estimated, for more details please check the interactive map .","url":"https://ses.jrc.ec.europa.eu/storage-inventory","attempts":[]},"inclusion_rule":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://ses.jrc.ec.europa.eu/storage-inventory","note":"Inventory page: disclaimer and technology list, no inclusion threshold."},{"url":"https://ses.jrc.ec.europa.eu/about-the-storage-inventory","note":"About page: policy context only, no inclusion rule."}]},"reference_date":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://ses.jrc.ec.europa.eu/storage-inventory-maps","note":"Map page shows no data date."},{"url":"https://ses.jrc.ec.europa.eu/storage-inventory","note":"Inventory page shows no data date."}]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://ses.jrc.ec.europa.eu/storage-inventory","note":"No update frequency stated."},{"url":"https://ses.jrc.ec.europa.eu/about-the-storage-inventory","note":"No update frequency stated."}]},"exclusions":{"value":"Values under 0.01 MW(h) shown as 'Non relevant'.","quote":"Note: \"Non relevant\" means under 0.01 MW(h)","url":"https://ses.jrc.ec.europa.eu/storage-inventory-maps","attempts":[]}},"key_fields":[{"field":"countries[] / technology[] / status","meaning":"Map filters: Germany 375, Electrochemical 36 (sub-types e.g. LFP 82), Operational 374."},{"field":"Power (MW) / Capacity (MWh)","meaning":"Range filters on project power and energy."}],"how_to_use":{"example_request":"https://ses.jrc.ec.europa.eu/storage-inventory-maps (filter Germany, Electrochemical, Operational in the page form)","example_result":"Page loads (HTTP 200) with filters 'Status: Announced Inactive Operational Permitted Under construction', 'Power (MW)', 'Capacity (MWh)'; no records retrieved outside a browser.","steps":["Use the map in a browser with filters Germany / Electrochemical / Operational; cross-check each project with the MaStR by name and place."],"reading_traps":["Disclaimer: 'mainly based on public data and data from Wood Mackenzie'; MWh partly estimated.","Projects aggregate units differently from MaStR rows; do not add both."]},"test":{"tested_on":"2026-11-26","method":"page_only","http_status":200,"content_type":"text/html; charset=utf-8","size_bytes":55050,"records_total":null,"records_for_country":null,"problems":["The export link used by the page (/storage-inventory-export) returned 404 with and without filter parameters.","Map records come from /storage-inventory-tool/api/projects with an app-specific header and an encoded payload; no documented download.","The JRC landing page on joint-research-centre.ec.europa.eu answered 429 to automated requests."]},"evidence":[{"claim":"Data origin.","url":"https://ses.jrc.ec.europa.eu/storage-inventory","quote":"Disclaimer: The European Energy Inventory Storage dataset is mainly based on public data and data from Wood Mackenzie."}],"members":[],"members_summary":null},{"source_id":"battery-charts","name":"Battery Charts (ISEA / PGS, RWTH Aachen University)","publisher":"RWTH Aachen University – ISEA and PGS","official":false,"landing_url":"https://battery-charts.de/battery-charts/","data_url":null,"access":"web_viewer_only","format":"Charts and Leaflet maps fed by the site's own JSON endpoint (wp-json/isea/v1/data); ranking CSV generated in the browser","license":"CC BY 4.0 (graphics and data on the page)","language":"en","has_coordinates":true,"location_precision":null,"publisher_type":"academic","adds":"Ready-made home / industrial / large-scale classification of MaStR batteries, a map of large-scale systems with operator and dates, and an operator ranking; CC BY 4.0.","first_seen_pass":1,"rank":5,"summary":"Academic MaStR evaluation with size classes (home <30 kWh and <30 kW; large ≥1000 kWh or ≥1000 kW), a large-storage map and operator ranking.","coverage_note":"Germany; viewer only, installation rows not downloaded in this test.","data_date":null,"caveats":["Derived from MaStR; not independent.","No tested download of installation rows."],"coverage":{"geographic":"Germany (MaStR universe)."},"fine_print":{"unit":{"value":"kWh/kW from MaStR; the large-storage map converts to MW and MWh.","quote":"Large-scale storage systems: ≥ 1000 kWh OR ≥ 1000 kW kWh: kilowatt hours; kW: kilowatts","url":"https://battery-charts.de/battery-charts/","attempts":[]},"inclusion_rule":{"value":"Automated evaluation of MaStR batteries split into three size classes.","quote":"Home storage systems: < 30 kWh AND < 30 kW Industrial storage systems: < 1000 kWh AND < 1000 kW Large-scale storage systems: ≥ 1000 kWh OR ≥ 1000 kW","url":"https://battery-charts.de/battery-charts/","attempts":[]},"reference_date":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://battery-charts.de/battery-charts/","note":"No data date printed in the page text."},{"url":"https://battery-charts.de/wp-content/themes/isea-wp/inc/charts/battery_charts/GeoMaps/largeBSS/leaflet.js","note":"Map script loads live rows from the API; no date field used."}]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://battery-charts.de/battery-charts/","note":"'automated evaluation' but no interval stated."},{"url":"https://battery-charts.rwth-aachen.de/?p=104","note":"Old methodology URL redirects to battery-charts.de/?p=104, which returns 404."}]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://battery-charts.de/battery-charts/","note":"No exclusion rule stated."},{"url":"https://battery-charts.de/wp-content/themes/isea-wp/inc/charts/battery_charts/GeoMaps/largeBSS/leaflet.js","note":"Map script drops rows without Ort or numeric coordinates (console warning), so unlocated units are not drawn."}]}},"key_fields":[{"field":"Ort, Breitengrad, Laengengrad, Bruttoleistung, NutzbareSpeicherkapazitaet, Inbetriebnahmedatum, AnlagenbetreiberName, Batterietechnologie","meaning":"Fields read by the large-storage map script (MaStR names)."},{"field":"rules.json (pattern → value)","meaning":"111 rules mapping unit/operator names to company groups for the ranking."}],"how_to_use":{"example_request":"https://battery-charts.de/battery-charts/ (large-scale storage map and ranking in a browser); rules: https://battery-charts.de/wp-content/themes/isea-wp/inc/charts/battery_charts/rankingLargeBatteriesChart/rules.json","example_result":"[ { \"pattern\": \"abo energy\", \"value\": \"ABO Energy/Wind\" }, { \"pattern\": \"abo wind\", \"value\": \"ABO Energy/Wind\" }, … ] (111 rules)","steps":["Use the size classes to split home, industrial and large-scale systems in your own MaStR extract.","Use the ranking (energy/power/count; active/planned) to see operator groups; verify sites in the MaStR."],"reading_traps":["Derived from the MaStR, not an independent survey: same gaps (masked natural persons, ≤30 kW locations).","Ranking is by company group after name normalisation, not by installation."]},"test":{"tested_on":"2026-11-26","method":"page_only","http_status":200,"content_type":"text/html; charset=UTF-8","size_bytes":492976,"records_total":null,"records_for_country":null,"problems":["Installation rows are served only through the page's JSON endpoint called with a key embedded in the page script; no published download of installation rows was found."]},"evidence":[{"claim":"Data basis is the MaStR.","url":"https://battery-charts.de/battery-charts/","quote":"With this website, we offer an automated evaluation of battery storage from the public database (MaStR) of the German Federal Network Agency."},{"claim":"License.","url":"https://battery-charts.de/battery-charts/","quote":"The graphics and data on this page are licensed under  CC BY 4.0  and may be used with credit to the authors and license"}],"members":[],"members_summary":null},{"source_id":"osm-overpass","name":"OpenStreetMap battery plants and generators (power=plant + plant:source=battery; generator:source=battery) via Overpass API","publisher":"OpenStreetMap contributors","official":false,"landing_url":"https://wiki.openstreetmap.org/wiki/Tag:plant:source%3Dbattery","data_url":"https://overpass-api.de/api/interpreter","access":"api","format":"OSM elements via Overpass QL (JSON/XML)","license":"unknown (licence page not opened in this session)","language":"en","has_coordinates":true,"location_precision":null,"publisher_type":"community","adds":"Mapped site outlines/points independent of the register, with tags for MW (plant:output:electricity) and MWh (plant:storage); coverage unknown.","first_seen_pass":1,"rank":6,"summary":"","coverage_note":"","data_date":null,"caveats":[],"coverage":{"geographic":"Worldwide; Germany via area or bounding-box query."},"fine_print":{"unit":{"value":"MW in plant:output:electricity, MWh in plant:storage (free text values).","quote":"The peak power output should be recorded in the plant:output:electricity =* tag, and the storage capacity in the plant:storage =* tag.","url":"https://wiki.openstreetmap.org/wiki/Tag:plant:source%3Dbattery","attempts":[]},"inclusion_rule":{"value":"Whatever volunteers map; plants as power=plant, single batteries as power=generator.","quote":"To map individual batteries, use power = generator with generator:source = battery .","url":"https://wiki.openstreetmap.org/wiki/Tag:plant:source%3Dbattery","attempts":[]},"reference_date":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://overpass-api.de/api/interpreter","note":"406 to curl; 502 via WebFetch; no osm_base timestamp obtained."},{"url":"https://overpass.private.coffee/api/interpreter","note":"Timed out (area and bbox count queries)."}]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://wiki.openstreetmap.org/wiki/Tag:plant:source%3Dbattery","note":"Wiki describes tagging only."},{"url":"https://overpass.kumi.systems/api/interpreter","note":"Timed out."}]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://wiki.openstreetmap.org/wiki/Tag:plant:source%3Dbattery","note":"No exclusion rule."},{"url":"https://api.ohsome.org/v1/elements/count","note":"503 'Down For Maintenance'."}]}},"key_fields":[{"field":"power=plant + plant:source=battery","meaning":"Battery storage plant outline."},{"field":"plant:output:electricity / plant:storage","meaning":"Power (MW) and energy (MWh) as mapped."},{"field":"generator:source=battery","meaning":"Individual battery units."},{"field":"operator / start_date","meaning":"Optional tags; presence not measured."}],"how_to_use":{"example_request":"[out:json][timeout:180];area[\"ISO3166-1\"=\"DE\"][admin_level=2]->.de;(nwr[\"plant:source\"=\"battery\"](area.de););out count;","example_result":"Not obtained: overpass-api.de answered '406 Not Acceptable' (nginx) to curl; two other public instances timed out.","steps":["Run the count query, then 'out tags center;' for records; parse MW/MWh text values.","Match to MaStR by place and name; OSM has no MaStR number tag requirement."],"reading_traps":["Coverage and tag completeness for Germany not measured in this session."]},"test":{"tested_on":"2026-11-26","method":"blocked","http_status":406,"content_type":"text/html","size_bytes":156,"records_total":null,"records_for_country":null,"problems":["overpass-api.de rejects clients without a browser-like identification (406 Not Acceptable to curl)."]},"evidence":[{"claim":"Tagging scheme for battery plants.","url":"https://wiki.openstreetmap.org/wiki/Tag:plant:source%3Dbattery","quote":"For a complete power plant, draw the outline and add: power = plant plant:source = battery plant:type = lithium_ion plant:output:electricity = xx MW plant:storage = xx MWh"}],"members":[],"members_summary":null}],"sector":{"regulator":{"name":"Bundesnetzagentur (BNetzA) – runs the Marktstammdatenregister","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Speicher/start.html"},"operators":{"structure":"many","note":"Millions of storage operators (mostly households) plus utilities, developers and investors; connected by 4 TSOs and many DSOs. The MaStR Marktakteure tables are the census.","census_url":"https://www.marktstammdatenregister.de/MaStR/Datendownload"},"publication_obligation":{"exists":"yes","norm":"Marktstammdatenregisterverordnung (MaStRV) §5 (registration of units incl. Stromspeicher within one month of commissioning) and §15 (public accessibility)","url":"https://www.gesetze-im-internet.de/mastrv/BJNR084210017.html","what_must_be_published":"Unit and storage master data (location, power, usable capacity, status, dates, operator) except street/coordinates of units ≤30 kW, natural-person operator data and protected KRITIS data.","frequency":"Event-driven: registration within one month of commissioning; daily public export."},"consolidated_republication":{"found":"yes","note":"The BNetzA itself publishes the consolidated register (viewer, JSON, daily XML) and a derived Kraftwerksliste; TSO and DSO sites publish requirements, not installation lists.","checked_pages":[{"organization":"Bundesnetzagentur","url":"https://www.marktstammdatenregister.de/MaStR/Datendownload","saw":"Daily Gesamtdatenexport of all public MaStR data, DL-DE-BY-2.0."},{"organization":"Bundesnetzagentur","url":"https://www.marktstammdatenregister.de/MaStR/Einheit/Einheiten/ErweiterteOeffentlicheEinheitenuebersicht","saw":"Public extended unit overview with storage columns incl. 'Nutzbare Speicherkapazität in kWh'."},{"organization":"Bundesnetzagentur","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Versorgungssicherheit/Erzeugungskapazitaeten/Kraftwerksliste/start.htm","saw":"Kraftwerksliste from MaStR with category Batteriespeicher (Datenstand 5. November 2026)."},{"organization":"Bundesnetzagentur","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Speicher/artikel.html","saw":"MaStR evaluation of Großbatteriespeicher (Stand 15.10.2025) and FAQ; no list."},{"organization":"Übertragungsnetzbetreiber (netztransparenz.de)","url":"https://www.netztransparenz.de/de-de/Systemdienstleistungen/Betriebsfuehrung/Batteriespeichersysteme","saw":"Operating requirements and Reifegradverfahren documents for BESS; no list of connected batteries."}]}},"national_registry":{"exists":"yes","note":"The MaStR (MaStRV, in force since 2017-07-01) is the single national register; every grid-connected battery must be registered and its public data are open under DL-DE-BY-2.0.","checked_pages":[{"organization":"Bundesnetzagentur – MaStR","url":"https://www.marktstammdatenregister.de/MaStR/Datendownload","saw":"Full public export, daily, with quarterly Stichtag files."},{"organization":"Bundesministerium der Justiz (gesetze-im-internet.de)","url":"https://www.gesetze-im-internet.de/mastrv/__15.html","saw":"§15 MaStRV publication rules and exceptions."},{"organization":"Bundesministerium der Justiz (gesetze-im-internet.de)","url":"https://www.gesetze-im-internet.de/mastrv/BJNR084210017.html","saw":"§2 Nr. 13 Stromspeicher definition; §5 registration duty and exemptions."},{"organization":"Bundesnetzagentur","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Speicher/artikel.html","saw":"Uses the MaStR for its own battery figures."}]},"if_unstructured":{"summary":"Not needed for most units: MaStR is structured. Operator documents only help for the few large units whose location MaStR anonymises, and to cross-check MWh.","recipe":["In MaStR, list operating battery units with Breitengrad empty and Bruttoleistung > 1000 kW (6 of 556 on 2026-11-26, 5 flagged IsAnonymisiertNettoleistungZuHoch).","Take EinheitName, AnlagenbetreiberName and StandortAnonymisiert ('59368 Werne; Deutschland') and search the operator's press releases.","Read the site sentence in the text (RWE 2021: 'am Gersteinwerk in Werne') and the MW/MWh figures (RWE 2023: 79 MWh); plain HTML text, no table extraction needed.","Record location as the named host site with precision 'site name', keep MaStR as the reference for kW, and log any MWh difference (MaStR 72,000 kWh vs 79 MWh)."],"location_method":"The documents opened name the host power-plant site (Gersteinwerk, Werne) but give no coordinates; MaStR keeps only PLZ and place for these units.","cross_with":["bnetza-kraftwerksliste (sites ≥10 MW with operator and year) by EinheitMastrNummer.","Bayerischer Landtag Drucksache 19/8074, Anlage 1: list of batteries >1 MW in operation in Bavaria taken from the MaStR (name, date, Ort, MW, MWh, voltage level): https://www.bayern.landtag.de/www/ElanTextAblage_WP19/Drucksachen/Schriftliche%20Anfragen/19_0008074.pdf","battery-charts (large-storage map and operator ranking) for plausibility of totals."],"where_published":[{"name":"Operator press releases (example: RWE press archive on rwe.com)","url":"https://www.rwe.com/presse/rwe-generation/2023-01-09-rwe-stellt-megabatterie-in-lingen-und-werne-fertig/","what":"Commissioning announcements naming the host site, power (MW), energy (MWh) and commissioning period of large batteries.","how_to_search_inside":"Search the operator site or a web search for the MaStR EinheitName plus the place from StandortAnonymisiert (e.g. 'Batteriespeicher Werne RWE'); no structured search.","example_document":{"url":"https://www.rwe.com/presse/rwe-ag/2021-07-22-rwe-baut-einen-der-groessten-batteriespeicher-deutschlands/","what_it_gives":"Site: «Die Anlage am Gersteinwerk in Werne wird über eine Leistung von 72 MW verfügen» (2021 release). Energy: «Werne (Nordrhein-Westfalen, 79 MWh)» (2023 release, https://www.rwe.com/presse/rwe-generation/2023-01-09-rwe-stellt-megabatterie-in-lingen-und-werne-fertig/)."}}]},"related_not_answering":[{"name":"BNetzA press release on battery grid-connection requests (2025-11-12)","url":"https://www.bundesnetzagentur.de/SharedDocs/Pressemitteilungen/DE/2025/20251112_Batteriespeicher.html","why":"National aggregates of connection requests/commitments and 921 operating units ≥ medium voltage; no installation list."},{"name":"SMARD – Developments at TSOs and DSOs (2026-08-20)","url":"https://www.smard.de/page/en/topic-article/5892/221346/developments-at-tsos-and-dsos","why":"Totals only (1,292 facilities ≥ medium voltage, ~3.6 GW, ~6 GWh); charts cover connection requests."},{"name":"BNetzA Speicher FAQ / MaStR evaluation (Stand 15.10.2025)","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Speicher/artikel.html","why":"Aggregate grid-scale totals (ca. 2.4 GW / 3.2 GWh), no list."},{"name":"Berlin Energieatlas – Stromspeicher (WMS/WFS)","url":"https://gdi.berlin.de/geonetwork/srv/api/records/52997190-61ee-48df-9858-c8779e071825","why":"Count and power aggregated by Bezirk, PLZ and city from MaStR (Stand 14.09.2026); not per installation."},{"name":"Energieatlas Rheinland-Pfalz – Batteriespeicher figures","url":"https://www.energieatlas.rlp.de/earp/startseite/news/energiewende-erfolgreich-gestalten-mit-batteriespeichern/zahlen-im-ueberblick","why":"State totals from MaStR (Datenstand 31.03.2025); no list."},{"name":"EEX Transparency – Germany storage","url":"https://www.eex-transparency.com/power/de/usage-capacity/storage/","why":"Aggregate filling level and working capacity; per-unit data only through a paid API."},{"name":"open-MaStR dataset on Zenodo","url":"https://zenodo.org/api/records/14843222","why":"Third-party CSV copy of the MaStR export, latest release 2025-02-09; the original BNetzA export is newer."}],"open_questions":["RWE Werne: MaStR gives 72,000 kWh usable, RWE's 2023 release 79 MWh; whether the gap is usable vs installed energy needs the operator or BNetzA.","Meaning of the viewer flag IsAnonymisiertNettoleistungZuHoch (large units shown only with PLZ/place) is not documented in the export documentation; it fits §15 Abs. 1 Nr. 1 c MaStRV (KRITIS) but BNetzA would have to confirm.","SMARD's 1,292 facilities ≥ medium voltage (Aug 2026) vs 3,101 MaStR units at Mittelspannung or above (Nov 2026): unit vs facility definition not stated."],"history":[{"pass":1,"date":"2026-11-26","role":"research","model":"claude-sonnet-5-5","rules_version":"2026-11-26-de-fr-baterias","note":"First research pass: MaStR tested via viewer JSON and export structure; site grouping, hybrid detection and masking quantified; Kraftwerksliste downloaded; JRC, Battery Charts and OSM not retrievable as data.","headline":{"official_data":"structured","non_official_data":"partial","national_registry":"yes"},"sources":{"total":6,"new":6,"dropped":0},"negatives":{"overturned":0,"confirmed":0},"effort":{"pages":53,"minutes":45}}],"local_terms":[{"term":"Marktstammdatenregister (MaStR)","language":"de","meaning":"Federal register of all generation and storage units, run by the Bundesnetzagentur; the official source for this question."},{"term":"Stromspeicher / Batteriespeicher","language":"de","meaning":"Electricity storage / battery storage; MaStR Energieträger 'Speicher', Speichertechnologie 'Batterie'."},{"term":"Großbatteriespeicher","language":"de","meaning":"Grid-scale battery; BNetzA usage: Bruttoleistung greater than 999 kW."},{"term":"Nutzbare Speicherkapazität","language":"de","meaning":"Usable storage capacity in kWh (MaStR field on the storage object SSE)."},{"term":"Inbetriebnahmedatum","language":"de","meaning":"Commissioning date of the unit (first technical commissioning)."},{"term":"Betriebs-Status: In Betrieb","language":"de","meaning":"Operating status filter value meaning 'in operation' (others: In Planung, vorübergehend / endgültig stillgelegt)."},{"term":"technische Lokation (SEL)","language":"de","meaning":"Technical location grouping all units behind common grid connection points; use it to build sites."},{"term":"Anlagenbetreiber","language":"de","meaning":"Operator of the unit; masked when a natural person."}],"provenance":{"pass_count":1,"models":["claude-sonnet-5-5"],"minutes_estimate":45,"pages_opened":53,"passes":[{"pass":1,"date":"2026-11-26","model":"claude-sonnet-5-5"}],"note":"Minutes are researcher estimates. Counts describe documented passes, not publication approval. Missing history or effort is not reconstructed."},"card_url":"https://georutter.org/v1/de/battery-storage.json","detail_url":"https://georutter.org/v1/de/battery-storage/detail.json","html_url":"https://georutter.org/de/battery-storage/","country_url":"https://georutter.org/v1/countries/de.json"}
