{"schema_version":"1.0","country":"de","country_name":"Germany","topic":"power-lines","question":"Where can I get the routes (geometry) of electricity transmission and distribution lines in Germany, with voltage level, operator and status?","territory":"de","territory_level":"country","parent_url":null,"published_on":"2026-11-27","research_reviewed_on":"2026-11-27","access_checked_on":"2026-11-27","answer":{"official_data":"partial","non_official_data":"usable","summary":"ATKIS provides open vectors for high-voltage overhead lines. BNetzA’s project layers cover transmission expansion sections with voltage, operator and status. JAO’s Core static grid model gives circuit voltage and operator without geometry. OpenStreetMap adds some distribution routes and cables, with variable completeness. VDE FNN serves generalised 380 and 220 kV routes. No complete open distribution dataset was verified.","main_caveats":["The ATKIS sources checked focus on overhead lines, with a documented capture threshold of 110 kV. Voltage, operator and status were unavailable in the samples. These sources do not provide a distribution cable inventory.","BNetzA layers cover only BBPlG/EnLAG expansion sections; 46 of 157 BBPlG features are 'Luftlinie' or 'Korridorverlauf', not routes.","VDE FNN geometry is generalised (about one vertex per 4.4 km), has no operator field and states no licence.","JAO/TSO static grid models list circuits by substation pair with TSO and kV but no geometry; the bundled HTML map draws straight lines.","TenneT's WMS returns images only; its 2018 terms require written permission to store, digitise or republish the data."],"confidence":"medium","confidence_reason":"All listed sources opened and queried (national OSM, DLM250, three Länder, JAO, BNetzA); DSO publication only sampled (WEMAG NAP, Bayernwerk blocked) and GDI-DE catalogue unreachable.","attributes":[{"attribute":"route_geometry","covered":"partial","source_ids":["bnetza-netzausbau-vorhaben","osm-power-lines","vde-fnn-hoechstspannungsnetz","atkis-ax-leitung","operator-wms-leitungsnetz","pypsa-eur-osm-network"],"note":"Official vectors: ATKIS overhead lines ≥110 kV and BNetzA expansion sections; OSM adds cables and MV/LV lines; TenneT WMS is image-only.","gap":"not_published","gap_note":"No official open routes of underground cables or MV/LV lines: checked BNetzA, BKG/Länder ATKIS, VNBdigital NAPs, four TSO sites, TenneT/Bayernwerk WMS, GovData (Düsseldorf points to Planauskunft)."},{"attribute":"voltage","covered":"partial","source_ids":["bnetza-netzausbau-vorhaben","osm-power-lines","vde-fnn-hoechstspannungsnetz","jao-core-static-grid-model","pypsa-eur-osm-network"],"note":"With geometry: BNetzA projects, VDE 380/220 kV and OSM (98% of line ways). JAO gives kV per TSO circuit without geometry; ATKIS has none.","gap":"not_published","gap_note":"No official voltage on 110 kV or MV/LV routes: ATKIS SPG empty in NRW (-9998), absent in HE, BY and DLM250; no other official layer found."},{"attribute":"operator","covered":"partial","source_ids":["bnetza-netzausbau-vorhaben","jao-core-static-grid-model","operator-wms-leitungsnetz","osm-power-lines"],"note":"BNetzA Vorhabenträger (projects), JAO TSO per circuit (no geometry), TenneT WMS owner by click, OSM operator on 59% of line ways.","gap":"not_published","gap_note":"No open per-line operator for the 110 kV and MV/LV networks; ATKIS and VDE lack the field; DSO plans only via Leitungsauskunft portals after registration."},{"attribute":"status","covered":"partial","source_ids":["bnetza-netzausbau-vorhaben","vde-fnn-hoechstspannungsnetz","osm-power-lines"],"note":"BNetzA per-section lifecycle (in Betrieb … vor/im Planfeststellungsverfahren); VDE operating vs planning/construction; OSM construction tags.","gap":"not_published","gap_note":"No official lifecycle field for the existing grid (ATKIS maps existing lines only); DSO planned measures only in NAP spreadsheets without geometry and UVP-Verbund notices."}]},"sources":[{"source_id":"bnetza-netzausbau-vorhaben","name":"Netzausbau – Kartenansicht: feature layers Vorhaben_BBPlG and Vorhaben_EnLAG (Monitoring_gdb)","publisher":"Bundesnetzagentur (BNetzA)","official":true,"landing_url":"https://www.netzausbau.de/Vorhaben/uebersicht/karte/karte.html","data_url":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer","access":"api","format":"ArcGIS REST FeatureServer (Esri JSON / GeoJSON polylines, EPSG:3857; outSR reprojects)","license":"unknown","language":"de","has_coordinates":true,"location_precision":"exact","publisher_type":"regulator","adds":"Only official vector routes with voltage, project sponsor (TSO) and per-section lifecycle status, for the transmission expansion projects under BBPlG and EnLAG.","first_seen_pass":1,"rank":1,"summary":"Official BNetzA routes of BBPlG/EnLAG transmission expansion sections with kV, TSO and lifecycle status.","coverage_note":"183 project sections nationwide; existing grid and distribution excluded.","data_date":"2026-10-08","caveats":["Typ 'Luftlinie'/'Korridorverlauf' are not routes.","Licence not stated on the map page."],"coverage":{"geographic":"Germany; transmission expansion projects of the Bundesbedarfsplangesetz (BBPlG, 157 section features) and EnLAG (26 section features); existing grid outside these projects is not included."},"fine_print":{"unit":{"value":"Voltage as text with kV in field Spannung (e.g. '380 kV', '525 kV', '320 bis 525 kV', 'unbekannt'); SHAPE__Length in Web Mercator metres, not ground metres.","quote":"'Spannung': '380 kV'","url":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer/0/query?where=1%3D1&outFields=*&f=json","attempts":[]},"inclusion_rule":{"value":"Sections of projects listed in BBPlG or EnLAG (field Grundlage 'BBPlG', 'BBPlG, PCI' or 'EnLAG'); one feature per project section and status.","quote":"'Grundlage': 'EnLAG'","url":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer/1/query?where=1%3D1&outFields=*&f=json","attempts":[]},"reference_date":{"value":"Layer data last edited 2026-10-08 (editingInfo.dataLastEditDate 1791464122346).","quote":"'dataLastEditDate': 1791464122346","url":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer/0?f=json","attempts":[]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://www.netzausbau.de/Vorhaben/uebersicht/karte/karte.html","note":"Map page states no update rhythm."},{"url":"https://www.netzausbau.de/Daten/DANA/de.html","note":"DANA page says BMWE and BNetzA report 'regelmäßig' from DANA data; no frequency for the map layer."}]},"exclusions":{"value":"Existing grid outside BBPlG/EnLAG projects; distribution (110 kV and below); 'Luftlinie' (33) and 'Korridorverlauf' (13) features are not routes.","quote":"'Typ': 'Luftlinie'","url":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer/0/query?where=1%3D1&outFields=*&f=json","attempts":[]}},"key_fields":[{"field":"Vorhaben","meaning":"Project section name (endpoints)."},{"field":"Vorhabennu","meaning":"Project number, e.g. 'BBPlG 15', 'EnLAG 07'."},{"field":"Vorhabenst","meaning":"Lifecycle state of the section (e.g. 'Abschnitt in Betrieb', 'Abschnitt genehmigt oder im Bau', 'Abschnitt vor/im Planfeststellungsverfahren')."},{"field":"Typ","meaning":"Geometry kind: 'Trassenverlauf' (route), 'Korridorverlauf' (corridor) or 'Luftlinie' (straight line)."},{"field":"Spannung","meaning":"Voltage as text with unit."},{"field":"Vorhabentr","meaning":"Project sponsor = TSO (e.g. 'Amprion', '50Hertz, TenneT')."},{"field":"Ausführung / Technik","meaning":"Overhead line, underground or submarine cable; AC or DC."},{"field":"Datenquell","meaning":"Who supplied the geometry (TSO, '-' or 'digitalisiert')."}],"how_to_use":{"example_request":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer/0/query?where=Vorhabenst%3D%27Abschnitt+genehmigt+oder+im+Bau%27&outFields=Vorhaben,Vorhabennu,Vorhabenst,Typ,Spannung,Vorhabentr,Ausf%C3%BChrung&returnGeometry=false&resultRecordCount=1&f=json","example_result":"{'Vorhaben': 'Punkt Metternich – Niederstedem', 'Vorhabennu': 'BBPlG 15', 'Vorhabenst': 'Abschnitt genehmigt oder im Bau', 'Typ': 'Trassenverlauf', 'Spannung': '380 kV', 'Vorhabentr': 'Amprion', 'Ausführung': 'Freileitung'} (returnCountOnly: 41)","steps":["Query layer 0 (BBPlG, 157 features) and layer 1 (EnLAG, 26 features) with where=1=1&outFields=*&outSR=4326&f=json (maxRecordCount 2000, one page suffices).","Keep Typ='Trassenverlauf' for actual routes; treat 'Korridorverlauf' and 'Luftlinie' as indicative only.","Use Vorhabenst for lifecycle and Vorhabentr for the operator; split multi-operator values such as '50Hertz, TenneT'.","Offshore grid connections are in the separate layer Anbindungsleitungen/FeatureServer/0 (5 features, field Name only)."],"reading_traps":["33 BBPlG features are Typ 'Luftlinie' and 13 'Korridorverlauf': straight lines or corridors, not routes.","Spannung is 'unbekannt' in 23 BBPlG features and null in 1; one feature reads '320 bis 525 kV'.","SHAPE__Length is in Web Mercator units (about 1.6× ground length at 52° N).","Status 'Abschnitt fertiggestellt' (8+4) differs from 'Abschnitt in Betrieb' (28+17); both are completed states.","Vorhabentr can list two TSOs for a shared section (e.g. '50Hertz, TenneT' 18 features)."]},"test":{"tested_on":"2026-11-27","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":null,"records_total":183,"records_for_country":183,"problems":[]},"evidence":[{"claim":"The netzausbau.de map loads these ArcGIS feature layers.","url":"https://www.netzausbau.de/Vorhaben/uebersicht/karte/karte.html","quote":"https://services-eu1.arcgis.com/TJm8oSvOdJUQvQT5/arcgis/rest/services/Monitoring_gdb/FeatureServer/0"},{"claim":"Underlying monitoring database DANA is not public.","url":"https://www.netzausbau.de/Daten/DANA/de.html","quote":"Die Webanwendung ist für die Übertragungsnetzbetreiber, die Genehmigungsbehörden, das Bundeswirtschaftsministerium sowie die Bundesnetzagentur zugänglich."}],"members":[],"members_summary":null},{"source_id":"osm-power-lines","name":"OpenStreetMap power=line / power=cable / power=minor_line (via Overpass API)","publisher":"OpenStreetMap contributors","official":false,"landing_url":"https://wiki.openstreetmap.org/wiki/Power_networks/Germany","data_url":"https://maps.mail.ru/osm/tools/overpass/api/interpreter","access":"api","format":"Overpass API JSON/XML (ways with node geometry); OSM extracts (PBF)","license":"ODbL 1.0","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"community","adds":"Open mapped routes include transmission and distribution lines, cables and minor lines. Voltage and operator tags vary by feature.","first_seen_pass":1,"rank":2,"summary":"OSM via Overpass: 51,354 power=line ways in Germany, 98% with voltage, 59% with operator, plus cables and minor lines.","coverage_note":"All voltage levels; volunteer completeness, cables underrepresented.","data_date":"2026-11-27","caveats":["Operator missing on 41% of line ways.","Status only via construction tags."],"coverage":{"geographic":"Germany, all voltage levels mapped by volunteers; completeness not guaranteed, cables underrepresented."},"fine_print":{"unit":{"value":"voltage in volts without unit, several circuits separated by ';' (e.g. 380000;110000).","quote":"voltage=*: Enter volts with no unit or digit grouping","url":"https://wiki.openstreetmap.org/wiki/Power_networks/Germany","attempts":[]},"inclusion_rule":{"value":"Whatever contributors map: power=line (overhead transmission/HV), power=minor_line (MV/LV overhead), power=cable (underground/submarine).","quote":null,"url":null,"attempts":[{"url":"https://wiki.openstreetmap.org/wiki/Power_networks/Germany","note":"German wiki page documents tagging but states no inclusion threshold."}]},"reference_date":{"value":"Live database; Overpass timestamp_osm_base 2026-11-27T08:04:02Z for the national counts.","quote":"\"timestamp_osm_base\": \"2026-11-27T08:04:02Z\"","url":"https://maps.mail.ru/osm/tools/overpass/api/interpreter","attempts":[]},"update_frequency":{"value":"Continuous (minutely replication on Overpass).","quote":null,"url":null,"attempts":[{"url":"https://maps.mail.ru/osm/tools/overpass/api/interpreter","note":"timestamp_osm_base minutes behind query time (08:04Z at 08:0xZ)."}]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://wiki.openstreetmap.org/wiki/Power_networks/Germany","note":"Wiki marks planned lines 'Weg noch nicht definiert' and is flagged out of date; no statement of exclusions."}]}},"key_fields":[{"field":"power","meaning":"line (overhead), minor_line (MV/LV overhead), cable (underground/submarine)."},{"field":"voltage","meaning":"Volts; ';' separates circuits of different voltage."},{"field":"operator","meaning":"Operator name; spelling varies (e.g. 'TenneT', 'TenneT TSO GmbH')."},{"field":"circuits / cables / wires","meaning":"Number of circuits, conductor sets, bundle type."},{"field":"name / ref","meaning":"Line name and line number (e.g. 'Ltg 449 Mecklar - Vieselbach')."},{"field":"construction:power / power=construction","meaning":"Lines under construction."}],"how_to_use":{"example_request":"POST data=[out:json][timeout:600];area[\"ISO3166-1\"=\"DE\"][admin_level=2]->.de;way[\"power\"=\"line\"](area.de)->.l;.l out count;way.l[\"voltage\"]->.v;.v out count;way.l[\"operator\"]->.o;.o out count;way[\"power\"=\"cable\"](area.de);out count;way[\"power\"~\"construction\"][\"construction\"~\"line|cable\"](area.de);out count;way[\"construction:power\"~\"line|cable\"](area.de);out count; to https://maps.mail.ru/osm/tools/overpass/api/interpreter","example_result":"power=line 51354 ways; with voltage 50387; with operator 30254; power=cable 6945; power=construction line|cable 420; construction:power line|cable 570","steps":["Query Germany by area (ISO3166-1=DE) or per Land (ISO3166-2=DE-TH etc.); national queries take 2+ minutes and can return 504, so split by Land.","Use out geom (or out body + recurse) to get coordinates; e.g. way(29023494);out tags geom; returned 'Ltg 449 Mecklar - Vieselbach', operator '50Hertz Transmission', voltage 380000.","Split voltage on ';' and convert volts to kV; normalise operator spellings.","Union power=line, power=minor_line and power=cable for a full network; add construction tags for status."],"reading_traps":["overpass-api.de answered HTTP 406 to plain curl requests; maps.mail.ru instance answered (twice 504 under load).","41% of German power=line ways lack operator (30254 of 51354 tagged); Thüringen sample 86% (1369/1588).","Operator values vary per TSO (wiki lists 'TenneT', 'TenneT TSO', 'TenneT TSO GmbH', 'TenneT_TSO').","No lifecycle tag for 'in operation'; only construction/proposed tagging, used on 420 + 570 ways.","UFZ's 2016 OSM-derived shapefile (CC BY-NC-SA, request form) is an older snapshot of the same data."]},"test":{"tested_on":"2026-11-27","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":1232,"records_total":51354,"records_for_country":51354,"problems":["overpass-api.de returns HTTP 406 to requests without browser headers; other public instance used."]},"evidence":[{"claim":"Lines are tagged with operator and voltage.","url":"https://wiki.openstreetmap.org/wiki/WikiProject_Power_networks/Germany/TenneT","quote":"Die Leitung ist neben power=line mit operator=*, voltage=*, wires=* versehen."},{"claim":"Licence of query results.","url":"https://maps.mail.ru/osm/tools/overpass/api/interpreter","quote":"The data included in this document is from www.openstreetmap.org. The data is made available under ODbL."}],"members":[],"members_summary":null},{"source_id":"vde-fnn-hoechstspannungsnetz","name":"Karte \"Deutsches Höchstspannungsnetz\" – ArcGIS feature layer Leitungen_Info","publisher":"Forum Netztechnik/Netzbetrieb im VDE (VDE FNN)","official":false,"landing_url":"https://www.vde.com/de/fnn/dokumente/karte-deutsches-hoechstspannungsnetz","data_url":"https://services1.arcgis.com/LVZ4P2ZNVc4ceCSD/arcgis/rest/services/Leitungen_Info/FeatureServer/0","access":"api","format":"ArcGIS REST FeatureServer (JSON/GeoJSON polylines, EPSG:25832)","license":"unknown","language":"de","has_coordinates":true,"location_precision":"exact","publisher_type":"commercial","adds":"Single consolidated layer of all four TSOs' 380/220 kV lines, HVDC, interconnectors and offshore links with voltage, circuits, underground flag and in-operation vs planning/construction status.","first_seen_pass":1,"rank":3,"summary":"VDE FNN layer of 836 EHV line features (380/220 kV, HVDC, offshore) with kV, circuits, cable flag and operating vs planned status.","coverage_note":"All four TSOs; no 110 kV; no operator field.","data_date":"2025-10-22","caveats":["Generalised geometry (~1 vertex/4.4 km).","Not official; licence not stated."],"coverage":{"geographic":"Germany incl. EEZ offshore links; extra-high voltage only (380/220 kV AC, HVDC, 150/220 kV offshore)."},"fine_print":{"unit":{"value":"Voltage and circuits encoded in text class leitungen_visu (e.g. '380 kV, 2 Stromkreise, in Betrieb'); label_popup gives circuits × kV ('2 x 220 kV').","quote":"'380 kV, 2 Stromkreise, in Betrieb'","url":"https://services1.arcgis.com/LVZ4P2ZNVc4ceCSD/arcgis/rest/services/Leitungen_Info/FeatureServer/0/query?where=1%3D1&outFields=leitungen_visu&returnDistinctValues=true&f=json","attempts":[]},"inclusion_rule":{"value":"380/220 kV, HVDC, interconnectors and offshore connections of the four TSOs, existing plus under construction or in implementation planning.","quote":"In der Karte sind neben den bestehenden Leitungen auch die im Bau und bereits in der Umsetzungsplanung befindlichen Leitungen dargestellt.","url":"https://www.vde.com/de/fnn/dokumente/karte-deutsches-hoechstspannungsnetz","attempts":[]},"reference_date":{"value":"Layer last edited 2025-10-22 (editingInfo.lastEditDate); print maps 'Stand 01/2026'.","quote":"'lastEditDate': 1761132159111","url":"https://services1.arcgis.com/LVZ4P2ZNVc4ceCSD/arcgis/rest/services/Leitungen_Info/FeatureServer/0?f=json","attempts":[]},"update_frequency":{"value":"Online map yearly, print every two years.","quote":"VDE FNN aktualisiert die Online-Karte jährlich und die Druckversionen alle zwei Jahre.","url":"https://www.vde.com/de/fnn/dokumente/karte-deutsches-hoechstspannungsnetz","attempts":[]},"exclusions":{"value":"110 kV and lower voltages; no operator attribute.","quote":null,"url":null,"attempts":[{"url":"https://services1.arcgis.com/LVZ4P2ZNVc4ceCSD/arcgis/rest/services/Leitungen_Info/FeatureServer/0?f=json","note":"Field list has no operator; page names only 380/220 kV, HGÜ, interconnectors, offshore."}]}},"key_fields":[{"field":"leitungs_name","meaning":"Line name with voltage and endpoints (null in 31 of 836)."},{"field":"leitungen_visu","meaning":"Class: voltage, circuits and status ('in Betrieb', 'in Planung/Bau neue Trasse', 'in Planung/Bau alte Trasse_220kV|2Strk. -> 380kV|2Strk.')."},{"field":"unterirdisch","meaning":"Underground cable flag 'Ja'/'Nein'."},{"field":"Projektstatus","meaning":"'in Bau'/'in Planung' on 16 records only; null elsewhere."}],"how_to_use":{"example_request":"https://services1.arcgis.com/LVZ4P2ZNVc4ceCSD/arcgis/rest/services/Leitungen_Info/FeatureServer/0/query?where=leitungen_visu+LIKE+%27%25in+Planung%25%27&outFields=leitungs_name,leitungen_visu,unterirdisch,Projektstatus&returnGeometry=false&resultRecordCount=1&f=json","example_result":"{'leitungs_name': '380-kV-Kabel Reuter - Mitte - Charlottenburg', 'leitungen_visu': 'in Planung/Bau alte Trasse_380kV|2Strk. -> 380kV|2Strk.', 'unterirdisch': 'Ja', 'Projektstatus': None} (count: 145)","steps":["Query where=1=1&outFields=*&outSR=4326&f=json (836 features, under maxRecordCount 2000).","Parse leitungen_visu into voltage, circuits and status ('in Betrieb' vs 'in Planung/Bau').","Use unterirdisch for overhead vs cable; join operator from JAO static grid model or BNetzA by line name."],"reading_traps":["Geometry is generalised: 6,844 vertices for 30,313 km (about one vertex per 4.4 km).","Class 'offshore | AC | 220 kV' also holds 150 kV cables (label_popup '150 kV').","unterirdisch has 10 values written with quotes (\"'Nein'\").","Projektstatus is null in 820 of 836 records; use leitungen_visu for status.","57 vertices fall outside a German bounding box (interconnectors, offshore)."]},"test":{"tested_on":"2026-11-27","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":521874,"records_total":836,"records_for_country":836,"problems":[]},"evidence":[{"claim":"Scope of the map.","url":"https://www.vde.com/de/fnn/dokumente/karte-deutsches-hoechstspannungsnetz","quote":"Die Karte „Deutsches Höchstspannungsnetz“ umfasst die Höchstspannungsleitungen mit 380 und 220 Kilovolt, die HGÜ-Leitungen, die Interkonnektoren und Offshore-Netzanbindungen der vier Übertragungsnetzbetreiber 50Hertz, Amprion, TenneT TSO und TransnetBW."},{"claim":"The page embeds an ArcGIS app whose public web map 'VDE Webmap Public' lists the Leitungen_Info layer.","url":"https://www.vde.com/de/fnn/dokumente/karte-deutsches-hoechstspannungsnetz","quote":"https://gis-akademie.maps.arcgis.com/apps/instant/basic/index.html?appid=9aa59f747cdd45f29e2e33035e5178e4"}],"members":[],"members_summary":null},{"source_id":"jao-core-static-grid-model","name":"Core Static Grid Model (SGM) – External.xlsx, sheets Lines and Tielines","publisher":"Joint Allocation Office (JAO) for the Core TSOs (50Hertz, Amprion, TenneT TSO, TransnetBW and others)","official":true,"landing_url":"https://www.jao.eu/static-grid-model","data_url":"https://www.jao.eu/sites/default/files/2026-06/202603_Core%20Static%20Grid%20Model_9th%20release.zip","access":"direct_download","format":"ZIP with XLSX, DOCX handbook and HTML leaflet map","license":"unknown","language":"en","has_coordinates":false,"location_precision":"none","publisher_type":"operator","adds":"Official per-circuit list of the meshed 380/220 kV grid with TSO, voltage, substation endpoints, EIC code and length – operator per line, but no geometry.","first_seen_pass":1,"rank":4,"summary":"JAO Core Static Grid Model: official per-circuit list of German 380/220 kV lines with TSO, kV, endpoints and length.","coverage_note":"848 German TSO circuits; meshed grid only; no geometry.","data_date":"2026-03","caveats":["No coordinates; HTML map uses straight lines."],"coverage":{"geographic":"Core capacity calculation region; German TSOs: 848 line circuits (Amprion 350, TenneT 260, 50Hertz 142, TransnetBW 96) plus tie-lines."},"fine_print":{"unit":{"value":"Voltage_level(kV); Length_(km); currents in A; R/X in Ω, B in μS.","quote":"Voltage_level(kV)","url":"https://www.jao.eu/sites/default/files/2026-06/202603_Core%20Static%20Grid%20Model_9th%20release.zip","attempts":[]},"inclusion_rule":{"value":"Relevant 380/220 kV circuits of the meshed grid with horizontal transmission tasks; radial spurs and plant connections excluded (50Hertz definition).","quote":"relevante 380-kV- und 220-kV-Stromkreise des vermaschten Übertragungsnetzes","url":"https://www.50hertz.com/de/Transparenz/Kennzahlen/Netzdaten/StatischesNetzmodell","attempts":[]},"reference_date":{"value":"9th release 202603 (published 01/03/2026 on JAO); 50Hertz own table 'Status: 31.12.2025'.","quote":"Status: 31.12.2025","url":"https://www.50hertz.com/cdn/files/c62467c9-a504-4be0-c6ee-08debc9147be/statisches%20netzmodell%20-%20datentabelle%202025-q4%20-%20oo.xlsx","attempts":[]},"update_frequency":{"value":"Two releases per year on JAO (03 and 09 editions); 50Hertz updates retrospectively at year end.","quote":"retrospektiv zum Jahresende","url":"https://www.50hertz.com/de/Transparenz/Kennzahlen/Netzdaten/StatischesNetzmodell","attempts":[]},"exclusions":{"value":"Radial lines and generator/customer connection lines; 110 kV; geometry.","quote":"werden grundsätzlich nicht dargestellt","url":"https://www.50hertz.com/de/Transparenz/Kennzahlen/Netzdaten/StatischesNetzmodell","attempts":[]}},"key_fields":[{"field":"NE_name","meaning":"Circuit name 'Substation1 - Substation2 number'."},{"field":"EIC_Code","meaning":"ENTSO-E identification code of the circuit."},{"field":"TSO","meaning":"Operator ('AMPRION GMBH', 'TENNETGMBH', '50HERTZ', 'TRANSNETBW')."},{"field":"Substation_1/2 Full_name","meaning":"Endpoint substations."},{"field":"Voltage_level(kV)","meaning":"380 or 220."},{"field":"Length_(km)","meaning":"Circuit length."}],"how_to_use":{"example_request":"https://www.jao.eu/sites/default/files/2026-06/202603_Core%20Static%20Grid%20Model_9th%20release.zip → '202603_Core Static Grid Model_External.xlsx', sheet 'Lines', header in row 2, data from row 3","example_result":"Altdöbern - Streumen 563 | 11T0-0000-0949-E | 50HERTZ | Altdöbern | Streumen | 380 | … | 70.53 (km)","steps":["Unzip and open sheet 'Lines' (2,632 circuits) and 'Tielines' (333); row 1 holds group headers, row 2 column names.","Filter TSO in {'AMPRION GMBH','TENNETGMBH','50HERTZ','TRANSNETBW'} for Germany.","Join to geometry by substation pair or line number (e.g. VDE leitungs_name, OSM ref/name); no coordinates in the file."],"reading_traps":["The bundled HTML map draws all 2,951 polylines with exactly 2 vertices: straight lines between substations, not routes.","TSO labels differ from company names (TENNETGMBH; TENNET NL is the Dutch TSO).","One circuit can be split into sections sharing an EIC code (e.g. 302/1 and 302/2).","Files prefixed 'outdated_' on the JAO page are superseded releases."]},"test":{"tested_on":"2026-11-27","method":"download","http_status":200,"content_type":"application/zip","size_bytes":2495860,"records_total":2632,"records_for_country":848,"problems":[]},"evidence":[{"claim":"Amprion moved its static grid model to JAO.","url":"https://www.amprion.net/Strommarkt/Engpassmanagement/Statisches-Netzmodell/","quote":"Die Daten zum statischen Netzmodell finden Sie ab sofort gesammelt für die Core Region auf der Homepage von JAO."},{"claim":"TransnetBW links its static grid model to JAO.","url":"https://www.transnetbw.de/en/energy-market/congestion-management/congestion","quote":"Data on the static grid model can be found here"}],"members":[{"name":"50Hertz Transmission – Statisches Netzmodell","landing_url":"https://www.50hertz.com/de/Transparenz/Kennzahlen/Netzdaten/StatischesNetzmodell","data_url":"https://www.50hertz.com/cdn/files/c62467c9-a504-4be0-c6ee-08debc9147be/statisches%20netzmodell%20-%20datentabelle%202025-q4%20-%20oo.xlsx","access":"direct_download","tested":true,"data_found":true,"note":"Own XLSX 2025-Q4: 142 circuits (119×380, 23×220 kV) + 20 tie-lines; map PDF/JPG is a single-line overview."},{"name":"Amprion – Statisches Netzmodell","landing_url":"https://www.amprion.net/Strommarkt/Engpassmanagement/Statisches-Netzmodell/","data_url":null,"access":"pdf","tested":true,"data_found":false,"note":"Page offers only a schematic PDF (Stand 31.03.2026) and points to JAO for the data."},{"name":"TransnetBW – Congestion management","landing_url":"https://www.transnetbw.de/en/energy-market/congestion-management/congestion","data_url":null,"access":"web_viewer_only","tested":true,"data_found":false,"note":"Links 'Data on the static grid model' to jao.eu."},{"name":"TenneT TSO – transparency pages","landing_url":"https://www.tennet.eu/de/strommarkt/transparenz/transparenz-deutschland","data_url":null,"access":null,"tested":false,"data_found":null,"note":"HTTP 403 to plain curl; TenneT lines (260) present in the JAO file."}],"members_summary":{"total":4,"listed":4,"tested":3,"data_found":1,"scope_note":"The four German TSOs; all four appear in the JAO Core SGM; 50Hertz also publishes its own table.","pattern":"TSO site → Strommarkt/Transparenz → Engpassmanagement → 'Statisches Netzmodell'"},"member_scope":{"total":4,"note":"The four German TSOs; all four appear in the JAO Core SGM; 50Hertz also publishes its own table.","pattern":"TSO site → Strommarkt/Transparenz → Engpassmanagement → 'Statisches Netzmodell'"}},{"source_id":"operator-wms-leitungsnetz","name":"Grid operators' public map services (TenneT TSO 'Web Map Service mit den Netzdaten'; Bayernwerk Netz MV service)","publisher":"TenneT TSO GmbH; Bayernwerk Netz GmbH","official":true,"landing_url":"https://geoportal.bayern.de/geoportalbayern/seiten/dienste","data_url":null,"access":"api","format":"OGC WMS 1.3.0 (PNG images; GetFeatureInfo in GeoJSON/text)","license":"TenneT Nutzungsbedingungen (Stand 07/2018); 'Kostenfrei fuer private Nutzung'","language":"de","has_coordinates":false,"location_precision":"none","publisher_type":"operator","adds":"Operator's own large-scale positions of its lines, cables and pylons (TenneT area), with owner, line number and overhead/cable type by click.","first_seen_pass":1,"rank":5,"summary":"TenneT TSO publishes a WMS of its lines, cables and pylons; owner and line number by click, images only.","coverage_note":"TenneT area; Bayernwerk MV service blocked.","data_date":null,"caveats":["No vector geometry.","2018 terms restrict storage."],"coverage":{"geographic":"TenneT TSO supply area (capabilities bbox 5.33–14.93° E, 47.33–58.28° N); Bayernwerk MV network in Bavaria (not accessible)."},"fine_print":{"unit":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?request=GetCapabilities&service=WMS","note":"Leitungen layer attributes are Leitungstyp, Eigentümer, Leitungsnummer, Leitungsname; no voltage field."},{"url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?SERVICE=WMS&VERSION=1.3.0&REQUEST=GetFeatureInfo&LAYERS=Leitungen&QUERY_LAYERS=Leitungen&STYLES=&CRS=EPSG:4326&BBOX=49.90,10.05,50.10,10.35&WIDTH=400&HEIGHT=400&FORMAT=image/png&INFO_FORMAT=text/plain&I=73&J=259","note":"Text output lists the same four attributes."}]},"inclusion_rule":{"value":"TenneT transmission lines, cables, pylons and substation sites in its supply area.","quote":"Mit diesem Dienst stellt die TenneT TSO GmbH der Oeffentlichkeit ihr Stromuebertragungsnet und ihre Umspannwerksstandorte als frei zugaenglichen Web Map Service zur Verfuegung.","url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?request=GetCapabilities&service=WMS","attempts":[]},"reference_date":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?request=GetCapabilities&service=WMS","note":"No date in capabilities."},{"url":"https://geowms.tennet.eu/terms/Nutzungsbedingungen.pdf","note":"Terms dated 'Stand 07/2018' only."}]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?request=GetCapabilities&service=WMS","note":"Not stated; GDI-DE record (fortnightly per search snippet) could not be opened."},{"url":"https://geoportal.bayern.de/geoportalbayern/seiten/dienste","note":"Provider list gives URL and coverage only."}]},"exclusions":{"value":"Pylons only below 1:94,503 scale; cables only below about 1:2,315; other operators' lines not shown.","quote":"MaxScaleDenominator 94503.497024","url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?request=GetCapabilities&service=WMS","attempts":[]}},"key_fields":[{"field":"Leitungstyp","meaning":"'Freileitung' or cable."},{"field":"Eigentümer","meaning":"Owner (e.g. 'TenneT')."},{"field":"Leitungsnummer","meaning":"Line number (e.g. 'LH-07-B87')."},{"field":"Leitungsname","meaning":"Short line name (e.g. 'AS-BRF')."}],"how_to_use":{"example_request":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?SERVICE=WMS&VERSION=1.3.0&REQUEST=GetFeatureInfo&LAYERS=Leitungen&QUERY_LAYERS=Leitungen&STYLES=&CRS=EPSG:4326&BBOX=49.90,10.05,50.10,10.35&WIDTH=400&HEIGHT=400&FORMAT=image/png&INFO_FORMAT=application/geo%2Bjson&I=73&J=259&FEATURE_COUNT=5","example_result":"{\"geometry\": null, \"properties\": {\"Leitungstyp\": \"Freileitung\", \"Eigentümer\": \"TenneT\", \"Leitungsnummer\": \"LH-07-B87\", \"Leitungsname\": \"AS-BRF\"}}","steps":["Use GetMap (layers Leitungen, Energiekabel, Maste, UW-Standorte) as a background in GIS.","Click (GetFeatureInfo) for owner and line number; no vector geometry is returned.","Check the Nutzungsbedingungen before storing or redistributing."],"reading_traps":["Images only: GetFeatureInfo returns geometry null; the ArcGIS REST endpoint returns 404.","Terms (07/2018): storage, digitisation or online publication need TenneT's written permission; use 'nur in analoger Form oder als PDF'.","Bayernwerk's MV service (geodaten.bayernwerk.com/bag_energieatlas_ms) answered 403 with a Cloudflare challenge."]},"test":{"tested_on":"2026-11-27","method":"api_query","http_status":200,"content_type":"text/xml","size_bytes":28321,"records_total":null,"records_for_country":null,"problems":["Bayernwerk Netz MV service rejects automated clients (HTTP 403, Cloudflare 'Just a moment...')."]},"evidence":[{"claim":"Service listed in the Bavarian geoportal under provider TenneT TSO GmbH.","url":"https://geoportal.bayern.de/geoportalbayern/seiten/dienste","quote":"Web Map Service mit den Netzdaten der TenneT TSO GmbH"},{"claim":"Use restrictions.","url":"https://geowms.tennet.eu/terms/Nutzungsbedingungen.pdf","quote":"Die Daten der TenneT TSO GmbH dürfen nur in analoger Form oder als PDF genutzt und vervielfältigt werden."}],"members":[{"name":"TenneT TSO GmbH – Leitungsnetz WMS","landing_url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer?request=GetCapabilities&service=WMS","data_url":"https://geowms.tennet.eu/server/services/open/Leitungsnetz/MapServer/WMSServer","access":"api","tested":true,"data_found":true,"note":"GetMap and GetFeatureInfo work; image only; owner and line number per click."},{"name":"Bayernwerk Netz GmbH – Mittelspannungsnetz (Energie-Atlas) WMS","landing_url":"https://geodaten.bayernwerk.com/bag_energieatlas_ms/service?SERVICE=WMS&REQUEST=GetCapabilities","data_url":null,"access":null,"tested":false,"data_found":null,"note":"HTTP 403 Cloudflare challenge to curl and WebFetch; content known only from a search snippet of its GDI-DE record (20 kV lines and cables)."}],"members_summary":{"total":null,"listed":2,"tested":1,"data_found":1,"scope_note":"Universe = all grid operators (4 TSOs and several hundred DSOs, census in MaStR); only these two services were found; Amprion, 50Hertz and TransnetBW searches found none.","pattern":"Search Geoportal Bayern provider list or GDI-DE catalogue for 'Netzdaten' / 'Mittelspannungsnetz' + operator name."},"member_scope":{"total":null,"note":"Universe = all grid operators (4 TSOs and several hundred DSOs, census in MaStR); only these two services were found; Amprion, 50Hertz and TransnetBW searches found none.","pattern":"Search Geoportal Bayern provider list or GDI-DE catalogue for 'Netzdaten' / 'Mittelspannungsnetz' + operator name."}},{"source_id":"pypsa-eur-osm-network","name":"Prebuilt Electricity Network for PyPSA-Eur based on OpenStreetMap Data (v0.7)","publisher":"PyPSA-Eur team (Xiong, Fioriti, Neumann, Riepin, Brown) on Zenodo","official":false,"landing_url":"https://zenodo.org/records/18619025","data_url":"https://zenodo.org/api/records/18619025/files/lines.csv/content","access":"direct_download","format":"CSV with WKT LINESTRING geometry (lines.csv, buses.csv)","license":"ODbL 1.0","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"academic","adds":"Ready-to-use, topologically cleaned 220–400 kV network for Germany from OSM with voltage, circuits, underground flag and electrical parameters in one CSV.","first_seen_pass":1,"rank":6,"summary":"PyPSA-Eur OSM-based 220–400 kV network: 1,061 German lines with kV, circuits and cable flag.","coverage_note":"≥220 kV only.","data_date":"2026-02-12","caveats":["Derived from OSM; no operator."],"coverage":{"geographic":"Europe 220–750 kV; Germany 1,061 lines with a German bus (380: 663, 220: 391, 400: 7)."},"fine_print":{"unit":{"value":"voltage in kV; length in m; r, x in Ω; b in S.","quote":"voltage', 'i_nom', 'circuits', 's_nom', 'r', 'x', 'b', 'length'","url":"https://zenodo.org/api/records/18619025/files/lines.csv/content","attempts":[]},"inclusion_rule":{"value":"High-voltage grid 220–750 kV from OSM, cleaned heuristically.","quote":"This dataset contains a topologically connected representation of the European high-voltage grid (220 kV to 750 kV) constructed using OpenStreetMap data.","url":"https://zenodo.org/api/records/18619025","attempts":[]},"reference_date":{"value":"Version 0.7 published 2026-02-12.","quote":"\"publication_date\": \"2026-02-12\"","url":"https://zenodo.org/api/records/18619025","attempts":[]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://zenodo.org/api/records/18619025","note":"Versioned releases (0.6 Nov 2024, 0.7 Feb 2026); no schedule stated."}]},"exclusions":{"value":"Below 220 kV; no operator.","quote":null,"url":null,"attempts":[{"url":"https://zenodo.org/api/records/18619025/files/lines.csv/content","note":"Column list has no operator field."}]}},"key_fields":[{"field":"line_id / tags","meaning":"OSM way/relation ids (traceable to openstreetmap.org)."},{"field":"voltage","meaning":"kV."},{"field":"underground / under_construction","meaning":"'t'/'f' flags."},{"field":"geometry","meaning":"WKT LINESTRING in WGS84."},{"field":"bus0 / bus1","meaning":"Join to buses.csv, whose 'country' gives DE."}],"how_to_use":{"example_request":"https://zenodo.org/api/records/18619025/files/lines.csv/content","example_result":"merged_relation/1208415:c-380+1 | voltage 380 | circuits 1 | length 9351.89 | underground f | under_construction f | LINESTRING (6.61521432 51.47659284, …)","steps":["Read lines.csv with quotechar=\"'\" (geometry is WKT wrapped in single quotes).","Join bus0/bus1 to buses.csv and keep rows where either bus has country 'DE'."],"reading_traps":["With the default CSV quote character the WKT splits into many columns.","under_construction is 'f' for all 1,061 German lines: planned lines are not represented.","Derived from OSM: same gaps as OSM, plus merging of parallel circuits (ids 'merged_relation/…')."]},"test":{"tested_on":"2026-11-27","method":"download","http_status":200,"content_type":"text/csv","size_bytes":19806938,"records_total":9162,"records_for_country":1061,"problems":[]},"evidence":[{"claim":"Licence of the dataset.","url":"https://zenodo.org/api/records/18619025","quote":"'license': {'id': 'odc-odbl'}"}],"members":[],"members_summary":null},{"source_id":"atkis-ax-leitung","name":"ATKIS AX_Leitung (object type 51005, Freileitung) – BKG DLM250 WFS and Länder Basis-DLM","publisher":"Bundesamt für Kartographie und Geodäsie (BKG) and Länder surveying authorities (AdV)","official":true,"landing_url":null,"data_url":null,"access":"api","format":"WFS 2.0 (GML, GeoJSON, SHAPE-ZIP) for DLM250; Länder WFS/NAS/Shape for Basis-DLM","license":"dl-de/by-2-0 (DLM250); Länder licences vary (BY CC BY 4.0, HE free use, NRW open data)","language":"de","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Official open vector routes for high-voltage overhead lines. Voltage, operator and status were unavailable in the records checked.","first_seen_pass":1,"rank":7,"summary":"ATKIS AX_Leitung provides open routes for high-voltage overhead lines. The BKG DLM250 extract contains 12,986 records. The Länder also publish Basis-DLM layers.","coverage_note":"Nationwide; overhead ≥110 kV only.","data_date":"2025-12-31","caveats":["No voltage, operator or status.","No underground cables."],"coverage":{"geographic":"Germany, all Länder; overhead lines ≥110 kV only."},"fine_print":{"unit":{"value":"No voltage value: the Shape spec reserves SPG 'Spannungsebene' but it is empty (-9998) in NRW and absent in HE, BY and DLM250.","quote":"SPG              Short Integer     Spannungsebene                    51005","url":"https://sg.geodatenzentrum.de/web_public/gdz/dokumentation/deu/adv-ps_atkis-basis-dlm_shape_v2.2.pdf","attempts":[]},"inclusion_rule":{"value":"All overhead lines from 110 kV.","quote":"Erfassungskriterien Basis-DLM: Vollzählig >= 110 kV","url":"https://www.lgl-bw.de/export/sites/lgl/Produkte/Galerien/Dokumente/OK-ATKIS-Basis-DLM-BW-7.1.2.pdf","attempts":[]},"reference_date":{"value":"DLM250 product state 2025-12-31 (AX_Leitung updated to that date).","quote":"Produktstand: 2025-12-31","url":"https://sg.geodatenzentrum.de/web_public/gdz/dokumentation/deu/dlm250.pdf","attempts":[]},"update_frequency":{"value":"Basis-DLM: basic currency 3 years, priority updates 3–12 months.","quote":"Grundaktualität = 3 Jahre","url":"https://sg.geodatenzentrum.de/public/gdz/dokumentation/deu/basis-dlm.pdf","attempts":[]},"exclusions":{"value":"Underground cables, lines below 110 kV, planned lines; only BWF 1110 'Freileitung' exists.","quote":"Freileitung                                           1110 (G)","url":"https://www.lgl-bw.de/export/sites/lgl/Produkte/Galerien/Dokumente/OK-ATKIS-Basis-DLM-BW-7.1.2.pdf","attempts":[]}},"key_fields":[{"field":"objid","meaning":"Persistent ATKIS object id (e.g. 'DEBKGDL2000083QR', 'DEHE0462000051kd')."},{"field":"bwf / bauwerksfunktion","meaning":"Always 1110 = Freileitung."},{"field":"bemerkung (DLM250)","meaning":"'mit mehreren Mastreihen' on 3,326 of 12,986 features (parallel pylon rows)."},{"field":"beginn","meaning":"Object version start, not commissioning date."}],"how_to_use":{"example_request":"https://sgx.geodatenzentrum.de/wfs_dlm250?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetFeature&TYPENAMES=dlm250:objart_51005_l&COUNT=3&OUTPUTFORMAT=application/json&SRSNAME=EPSG:4326","example_result":"{'objart_txt': 'AX_Leitung', 'objid': 'DEBKGDL2000083QR', 'beginn': '2025-12-31T08:00:00Z', 'bwf': '1110', 'bemerkung': 'mit mehreren Mastreihen'} MultiLineString [[7.9958,47.5785],[7.9742,47.5928],…] (numberMatched 12986)","steps":["DLM250: one GetFeature with COUNT=20000 returns all 12,986 features as GeoJSON (5.8 MB).","For full Basis-DLM accuracy (±15 m) query each Land: e.g. Bayern geoservices.bayern.de/wfs/v1/ogc_atkis_basisdlm.cgi TYPENAMES=adv:AX_Leitung (2,703), Hessen gds.hessen.de …/atkis-bdlm/sf/wfs (1,205), NRW Shape ZIP layer sie03_l OBJART 51005 (3,524).","Add voltage/operator by spatial match with OSM or VDE; ATKIS itself carries none."],"reading_traps":["DLM250 is generalised: 51,913 km with one vertex per ~900 m.","SPG column exists in NRW Shape but holds -9998 in all 3,524 lines.","NRW Shape ZIP is 4.69 GB; the sie03_l.dbf can be read alone via HTTP Range (entries are stored uncompressed).","BKG wms_dop and some Land services are restricted; RLP Basis-DLM WFS is for registered users per search result (not opened)."]},"test":{"tested_on":"2026-11-27","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":5825935,"records_total":12986,"records_for_country":12986,"problems":[]},"evidence":[{"claim":"DLM250 licence and OSM permission.","url":"https://sgx.geodatenzentrum.de/wfs_dlm250?SERVICE=WFS&REQUEST=GetCapabilities","quote":"Die Daten werden geldleistungsfrei gemäß der Datenlizenz Deutschland Namensnennung 2.0 (https://www.govdata.de/dl-de/by-2-0) zur Verfügung gestellt."},{"claim":"Positional accuracy of Basis-DLM objects other than roads and waters.","url":"https://sg.geodatenzentrum.de/public/gdz/dokumentation/deu/basis-dlm.pdf","quote":"± 15 m für alle übrigen Objekte"}],"members":[{"name":"BKG – DLM250 WFS (national, generalised)","landing_url":"https://sg.geodatenzentrum.de/web_public/gdz/dokumentation/deu/dlm250.pdf","data_url":"https://sgx.geodatenzentrum.de/wfs_dlm250","access":"api","tested":true,"data_found":true,"note":"12,986 features, bwf 1110, no voltage; dl-de/by-2-0."},{"name":"BKG – Basis-DLM national compilation","landing_url":"https://sg.geodatenzentrum.de/public/gdz/dokumentation/deu/basis-dlm.pdf","data_url":null,"access":null,"tested":false,"data_found":null,"note":"Shape 6.5 GB zipped 'via Download oder Datenträger'; licence/price not shown on the opened documentation."},{"name":"Nordrhein-Westfalen – Basis-DLM Shape (opengeodata.nrw.de)","landing_url":"https://www.opengeodata.nrw.de/produkte/geobasis/lm/akt/basis-dlm/","data_url":"https://www.opengeodata.nrw.de/produkte/geobasis/lm/akt/basis-dlm/basis-dlm_EPSG25832_Shape.zip","access":"direct_download","tested":true,"data_found":true,"note":"3,524 AX_Leitung in sie03_l; SPG -9998 in all."},{"name":"Hessen – WFS HE Basis-DLM AAA-Modell-basiert","landing_url":"https://hebid.hessen.de/bdd/hlbk/Dokumente/Uebersicht_Geowebdienste_OpenData_V3.pdf","data_url":"https://www.gds.hessen.de/wfs2/aaa-suite/cgi-bin/atkis-bdlm/sf/wfs","access":"api","tested":true,"data_found":true,"note":"1,205 AX_Leitung; no spannungsebene element."},{"name":"Bayern – kennungsfreier WFS ATKIS Basis-DLM","landing_url":"https://geodaten.bayern.de/odd/m/3/pdf/newsletter_archiv/2024_02.pdf","data_url":"https://geoservices.bayern.de/wfs/v1/ogc_atkis_basisdlm.cgi","access":"api","tested":true,"data_found":true,"note":"2,703 AX_Leitung; CC BY 4.0; no spannungsebene."}],"members_summary":{"total":18,"listed":5,"tested":4,"data_found":4,"scope_note":"16 Länder Basis-DLM (Baden-Württemberg, Bayern, Berlin, Brandenburg, Bremen, Hamburg, Hessen, Mecklenburg-Vorpommern, Niedersachsen, Nordrhein-Westfalen, Rheinland-Pfalz, Saarland, Sachsen, Sachsen-Anhalt, Schleswig-Holstein, Thüringen) plus two BKG national products; 3 Länder and DLM250 tested.","pattern":"Land surveying open-data portal → 'ATKIS Basis-DLM' WFS or download → feature type AX_Leitung / layer sie03_l OBJART 51005."},"member_scope":{"total":18,"note":"16 Länder Basis-DLM (Baden-Württemberg, Bayern, Berlin, Brandenburg, Bremen, Hamburg, Hessen, Mecklenburg-Vorpommern, Niedersachsen, Nordrhein-Westfalen, Rheinland-Pfalz, Saarland, Sachsen, Sachsen-Anhalt, Schleswig-Holstein, Thüringen) plus two BKG national products; 3 Länder and DLM250 tested.","pattern":"Land surveying open-data portal → 'ATKIS Basis-DLM' WFS or download → feature type AX_Leitung / layer sie03_l OBJART 51005."}}],"sector":{"regulator":{"name":"Bundesnetzagentur (BNetzA)","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/VerteilerNetz/start.html"},"operators":{"structure":"many","note":"Four TSOs (50Hertz, Amprion, TenneT TSO, TransnetBW) for 220/380 kV and HVDC; several hundred DSOs for 110 kV and below (BNetzA names the 82 largest in NAP 2024).","census_url":"https://www.marktstammdatenregister.de/MaStR/Akteur/Marktakteur/IndexOeffentlich?filter=Marktfunktion~eq~%271%27~and~T%C3%A4tigkeitsstatus~eq~%272511%27"},"publication_obligation":{"exists":"yes","norm":"§ 14d and § 14e EnWG","url":"https://www.gesetze-im-internet.de/enwg_2005/__14d.html","what_must_be_published":"DSO Netzausbauplan incl. 'Netzkarten des Hochspannungs- und Mittelspannungsnetzes … mit den Engpassregionen', on the common internet platform within four weeks of completion; operators with <100,000 customers exempt. No obligation to publish route geometry as data found.","frequency":"Every two years, by 31 October, starting 2026."},"consolidated_republication":{"found":"partial","note":"BNetzA republishes TSO-supplied routes of expansion projects; JAO collects TSO static grid models; VNBdigital collects DSO plans as PDFs/XLSX. Nobody republishes the existing grid's routes.","checked_pages":[{"organization":"Bundesnetzagentur","url":"https://www.netzausbau.de/Vorhaben/uebersicht/karte/karte.html","saw":"Map backed by Monitoring_gdb feature layers (BBPlG/EnLAG), field Datenquell = TSO."},{"organization":"Bundesnetzagentur","url":"https://www.netzausbau.de/Daten/DANA/de.html","saw":"DANA monitoring database accessible only to TSOs, authorities, BMWE and BNetzA."},{"organization":"Bundesnetzagentur","url":"https://www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/VerteilerNetz/start.html","saw":"NAP results summarised on SMARD; points to vnbdigital.de; no route data."},{"organization":"VNBdigital (DSO platform)","url":"https://www.vnbdigital.de/","saw":"Per-DSO NAP documents (PDF, XLSX) via GraphQL; operator area layer, no line routes."},{"organization":"JAO","url":"https://www.jao.eu/static-grid-model","saw":"Core Static Grid Model releases 1–9 (ZIP)."}]}},"national_registry":{"exists":"partial","note":"No national register of line routes. BNetzA's public BBPlG/EnLAG layer covers only federal expansion projects; its source DANA and the Infrastrukturatlas are not public; ATKIS is a topographic record without grid attributes.","checked_pages":[{"organization":"Bundesnetzagentur","url":"https://www.netzausbau.de/Daten/DANA/de.html","saw":"DANA restricted to TSOs, approval authorities, BMWE and BNetzA."},{"organization":"Bundesnetzagentur","url":"https://www.bundesnetzagentur.de/SharedDocs/Downloads/DE/Sachgebiete/Telekommunikation/Unternehmen_Institutionen/ZIdB/Fact_Sheet_Infrastrukturatlas.pdf","saw":"'Der Infrastrukturatlas ist nicht öffentlich zugänglich'; passive infrastructure for gigabit roll-out."},{"organization":"Bundesnetzagentur","url":"https://bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/Datenuebertragung_Energiedatenportal/Uebersicht_Marktakteure/start.html","saw":"Operator census in MaStR; no line data."},{"organization":"Bundesministerium für Wirtschaft und Energie","url":"https://www.bundeswirtschaftsministerium.de/Redaktion/DE/Dossier/netze-und-netzausbau.html","saw":"Radware bot check returned instead of content (curl and WebFetch)."},{"organization":"BKG","url":"https://sg.geodatenzentrum.de/web_public/gdz/dokumentation/deu/dlm250.pdf","saw":"DLM250 AX_Leitung with BWF and BEMERKUNG only."},{"organization":"50Hertz Transmission","url":"https://www.50hertz.com/de/Transparenz/Kennzahlen/Netzdaten/StatischesNetzmodell","saw":"Static grid model table without geometry; single-line overview map."},{"organization":"JAO","url":"https://www.jao.eu/static-grid-model","saw":"Core SGM ZIP: circuits with TSO and kV, no coordinates."}]},"if_unstructured":{"summary":"Routes of planned or approved 110 kV–525 kV lines and DSO plans appear in approval documents (Lagepläne 1:2000, Masttabellen) and §14d network plans; these give operator, voltage and status.","recipe":["Take BNetzA sections with Vorhabenst 'vor/im Planfeststellungsverfahren' or 'genehmigt oder im Bau' and open the matching section page on netzausbau.de.","Download the decision folder 'Ordner 2 | Technische Pläne' (Masttabellen: operator, line number, voltage, pylon numbers and spans) and 'Ordner 3 | Lagepläne' (61 PDF sheets for Ultranet C1); large ZIPs can be listed by HTTP Range.","Read Masttabellen with pdftotext -layout; rows are split over two lines (span length on the following line).","For 110 kV DSO projects search UVP-Verbund by '110-kV' and Land; record Vorhabenträger, length and procedure stage.","For DSO planned measures read the VNBdigital 'Maßnahmen' XLSX (sheet Maßnahmenplan, header row 3) for status and overhead/cable; no coordinates."],"location_method":"Lagepläne are 1:2000 PDF sheets on the cadastral base (e.g. 'Katasteramt : Stadt Neuss') showing pylons and line axis; georeference against ALKIS/DOP or match to ATKIS AX_Leitung; Masttabellen carry no coordinates.","cross_with":["atkis-ax-leitung (route of existing ≥110 kV overhead lines)","osm-power-lines (voltage, operator, cables)","jao-core-static-grid-model (TSO circuits)","bnetza-netzausbau-vorhaben (status per section)"],"where_published":[{"name":"netzausbau.de – BNetzA project pages (NABEG Planfeststellung)","url":"https://www.netzausbau.de/Vorhaben/ansicht/de.html?nummer=2&gruppe=bbplg","what":"Applications, §21 documents and Planfeststellungsbeschlüsse for federal transmission projects, per section, with ZIP folders of technical plans and Lagepläne.","how_to_search_inside":"Choose project in 'Alle Vorhaben', then the section (e.g. 'Abschnitt C1') and the step 'Planfeststellungsbeschluss'; no full-text search across documents.","example_document":{"url":"https://www.netzausbau.de/SharedDocs/Downloads/DE/Vorhaben/02/C1/24/Ordner2_TechnischePlaene.zip?__blob=publicationFile","what_it_gives":"Reg_4_4_1 Masttabelle: 'Amprion GmbH'; '220-/380-kV-Höchstspannungsfreileitung Rommerskirchen - Osterath, Bl. 4570'; mast '55 … ABD6 … T1+5,0 … 47,84 … 71,86' with Mastabstand '370,59' m."}},{"name":"VNBdigital – Netzausbaupläne of DSOs (§ 14d/14e EnWG)","url":"https://www.vnbdigital.de/","what":"Per DSO: Netzausbauplan PDF with HV/MV network maps, plus 'Netzausbauplan_kompakt' and 'Maßnahmen' XLSX (measures with overhead/cable, km, Projektstatus, Genehmigungsstand).","how_to_search_inside":"SPA: search operator, open its page (e.g. /vnb/719); documents also via GraphQL gateway/graphql query vnb_gridExpansionDocumentsExternal(vnbId).","example_document":{"url":"https://www.vnbdigital.de/gateway/files?serviceName=vnb&fileId=6ae8a0ed7d860dcfa4cf645f","what_it_gives":"WEMAG Netz NAP 2026 p. 10 'Abbildung 2: Aktuelle Engpässe und geplante Netzmaßnahmen im 110-kV-Netz bis 2035' (schematic image); Maßnahmen XLSX row 'Erweiterung UW Bernitt 110-kV-Schaltanlage | Freileitung | 0.1 | im Bau'."}},{"name":"UVP-Verbund – environmental assessment portal of Bund and Länder","url":"https://www.uvp-verbund.de/","what":"Approval and screening notices for 110 kV and other line projects decided by Länder authorities (category 'Leitungsanlagen und vergleichbare Anlagen').","how_to_search_inside":"Freitextsuche (e.g. '110-kV-Freileitung' → 39 hits), filter by Land and procedure type; documents link to authority sites or cloud folders.","example_document":{"url":"https://www.uvp-verbund.de/trefferanzeige?docuuid=23ab1a0e-e6a9-416c-8b5e-c1874f0fe96a&q=110-kV-Freileitung","what_it_gives":"'110-kV-Freileitung Neuenhagen – Finow (HT-2014) einschließlich Einschleifung Tempelfelde (HT-2015)'; Vorhabenträger 'E.DIS Netz GmbH'; 'Gesamtlänge von ca. 40 km'; Auslegung 14.10.2026–15.12.2026."}}]},"related_not_answering":[{"name":"ENTSO-E Transmission System Map","url":"https://www.entsoe.eu/data/map/","why":"'Network elements are not located at their exact geographic location' – schematic positions."},{"name":"Netzentwicklungsplan Strom – Übersichtskarten NEP 2037/2045 (2025)","url":"https://www.netzentwicklungsplan.de/en/node/1560","why":"PNG overview maps of scenarios; interactive map offline; no routes or data."},{"name":"PCI-PMI Transparency Platform (CINEA)","url":"https://metadata.europe-geology.eu/record/basic/6a97bb29-19c4-4568-9532-18960a010e58","why":"Geometry 'does not prejudge or necessarily coincide with the final route'; service redirected to sorry.ec.europa.eu."},{"name":"Infrastrukturatlas (BNetzA)","url":"https://www.bundesnetzagentur.de/SharedDocs/Downloads/DE/Sachgebiete/Telekommunikation/Unternehmen_Institutionen/ZIdB/Fact_Sheet_Infrastrukturatlas.pdf","why":"Not public; covers ducts, masts and fibre for gigabit co-use, not power line routes."},{"name":"BIL Leitungsauskunft portal","url":"https://bil-leitungsauskunft.de/","why":"Routes construction enquiries to competent operators after registration; returns contacts, not a line dataset."},{"name":"VNBdigital operator area layer (layerUrl VNBGeoFeatures)","url":"https://www.vnbdigital.de/","why":"Service areas of operators (polygons), not line routes."},{"name":"Netzstrukturdaten of DSOs (e.g. Stromnetz Berlin on GovData)","url":"https://www.govdata.de/ckan/api/3/action/package_search?q=Freileitung&rows=8","why":"Aggregated circuit lengths per voltage level ('Stromkreislängen … je Netz- und Umspannebene'), no routes; linked XLSX returned 404."},{"name":"GridKit extract of ENTSO-E interactive map (Zenodo 55853, 2016)","url":"https://zenodo.org/records/55853","why":"Unofficial 2016 extract; 'coordinates will not correspond exactly to reality'."},{"name":"Regionalplanung Sachsen – Vorbehaltsgebiet Hochspannungsleitung","url":"https://luis.sachsen.de/arcgis/rest/services/wasser/CROSSDATA_DE_26_Energie_und_Leitungen__RP_Energie_a_elektricke_vedeni/FeatureServer","why":"Planning reservations at 1:100,000 (3 features, e.g. 'Kalkreuth - Radeburg, 110 kV'), not built routes."},{"name":"edna/evu+ map of grid operators","url":"https://www.solarserver.de/2026/08/05/neue-netzkarte-macht-energieerzeugung-in-deutschland-transparent/","why":"Connected generation capacity per operator area from MaStR; no lines."},{"name":"Operators' Netzschemapläne (KraftNAV) listed on the OSM wiki","url":"https://wiki.openstreetmap.org/wiki/Power_networks/Germany","why":"Schematic single-line network diagrams (links 2008–2010), not geographic routes."}],"open_questions":["TenneT's WMS capabilities say 'Kostenfrei fuer private Nutzung' while its terms (Stand 07/2018) forbid storage without written permission; whether newer terms apply can only be asked of TenneT."],"history":[{"pass":1,"date":"2026-11-27","role":"research","model":"claude-sonnet-5-5","rules_version":"2026-11-27-de-red-generacion-mineria","note":"First pass: official routes only for ATKIS overhead lines ≥110 kV and BNetzA expansion projects; JAO gives TSO/kV per circuit; OSM and VDE FNN fill voltage and status.","headline":{"official_data":"partial","non_official_data":"usable","national_registry":"partial"},"sources":{"total":7,"new":7,"dropped":0},"negatives":{"overturned":0,"confirmed":0},"effort":{"pages":84,"minutes":47}}],"local_terms":[{"term":"Freileitung","language":"de","meaning":"Overhead line; ATKIS bauwerksfunktion 1110 and BNetzA 'Ausführung'."},{"term":"Erdkabel","language":"de","meaning":"Underground cable (VDE 'unterirdisch', BNetzA 'Ausführung')."},{"term":"Statisches Netzmodell","language":"de","meaning":"TSO per-circuit grid table, now collected on JAO for the Core region."},{"term":"Netzausbauplan","language":"de","meaning":"DSO expansion plan (§ 14d EnWG) with Netzkarten, published on VNBdigital."},{"term":"Planfeststellungsbeschluss","language":"de","meaning":"Approval decision; annexes include Masttabellen and Lagepläne of the route."},{"term":"Vorhabenträger","language":"de","meaning":"Project sponsor (the TSO/DSO) in BNetzA and UVP records."},{"term":"Höchstspannung / Hochspannung","language":"de","meaning":"220/380 kV transmission / 110 kV distribution voltage levels."},{"term":"Leitungsauskunft / Planauskunft","language":"de","meaning":"Utility location enquiry for works; operator plans after registration."}],"provenance":{"pass_count":1,"models":["claude-sonnet-5-5"],"minutes_estimate":47,"pages_opened":84,"passes":[{"pass":1,"date":"2026-11-27","model":"claude-sonnet-5-5"}],"note":"Minutes are researcher estimates. Counts describe documented passes, not publication approval. Missing history or effort is not reconstructed."},"card_url":"https://georutter.org/v1/de/power-lines.json","detail_url":"https://georutter.org/v1/de/power-lines/detail.json","html_url":"https://georutter.org/de/power-lines/","country_url":"https://georutter.org/v1/countries/de.json"}