{"schema_version":"1.0","country":"es","country_name":"Spain","topic":"power-lines","question":"Where can I get the routes (geometry) of electricity transmission and distribution lines in Spain, with voltage level, operator and status?","territory":"es","territory_level":"country","parent_url":null,"published_on":"2026-11-19","research_reviewed_on":"2026-11-16","access_checked_on":null,"answer":{"official_data":"partial","non_official_data":"partial","summary":"No open official Spanish dataset provides all transmission and distribution line routes with exact voltage, operator and status. Nationally, IGN Base Topográfica Nacional (BTN 0710L_LIN_ELEC via vt-btn.idee.es MVT API or CNIG GeoPackage) gives overhead routes and banded voltages (<100, 100-150, 220, 400 kV), excluding underground/submarine cables, operator and status. Official operator and exact >=50 kV voltage exist for Andalucía (MIEA WFS) and transmission status appears in schematic MITECO 2025-2030 PDFs; REE Infored (request form) and Inkolan (paid DWG) hold operator plans, while OpenStreetMap/OpenInfraMap partially covers all fields nationally.","main_caveats":["IGN BTN 0710L_LIN_ELEC excludes all underground and submarine cables (lines stop at transition towers) and omits operator and status fields.","CNMC Circular 6/2025 access-capacity maps publish substation point nodes only, not line routes; none of Spain's 325 active DSOs publish open line-route GIS.","CNIG Centro de Descargas (BTN_T_Energia GeoPackage) drops automated HTTP requests (empty reply); programmatic access works via IGN/IDEE MVT tiles at vt-btn.idee.es.","ENTSO-E Grid Map explicitly warns elements are not at exact geographic coordinates; REE public GeoRED MapServer exposes only 63 sample circuits.","OpenStreetMap/OpenInfraMap maps 128,460 km in Spain (2026-11-15), but 19.5% lacks voltage tags and ~85% of lines in Madrid/Granada samples lack operator tags."],"confidence":"high","confidence_reason":"Verified official regulator, ministry, TSO, IGN/IDEE, regional WFS, ENTSO-E, OSM/OpenInfraMap, and Inkolan endpoints directly with live queries and file downloads.","attributes":[{"attribute":"route_geometry","covered":"partial","source_ids":["s001","s002","s003","s004","s005","s006","s008"],"note":"Coverage combines distinct components of the question; see the original detailed evidence and its geographic and technical limits.","gap":"not_checked","gap_note":"The original rows have different scopes. Their combination has not been established as complete; original rows are retained in internal curation."},{"attribute":"voltage","covered":"partial","source_ids":["s001","s002","s003","s004","s005","s007"],"note":"IGN BTN uses 4 bands (<100, 100-150, 220, 400 kV); Andalucía MIEA gives exact kV (>=50 kV); OSM has exact voltage on 80.5% of mapped length; ENTSO-E/MITECO cover >=132 kV.","gap":"not_published","gap_note":"No open national source gives exact kV for all distribution tiers (<100 kV); IGN BTN groups all lines below 100 kV and 100-150 kV into coarse bands."},{"attribute":"operator","covered":"partial","source_ids":["s002","s004","s006","s007","s008"],"note":"IGN BTN and ENTSO-E lack operator; Andalucía MIEA gives PROPIETARIO (>=50 kV); REE is statutory sole TSO; OSM tags operator on ~14% in samples; Inkolan organizes by partner DSO.","gap":"not_published","gap_note":"Outside Andalucía (>=50 kV) and statutory TSO REE, open GIS datasets lack distribution operator names across Spain's 325 active DSOs."},{"attribute":"status","covered":"partial","source_ids":["s003","s004","s005","s007"],"note":"IGN BTN and Andalucía MIEA lack status; MITECO 2025-2030 PDF shows existing/planned/retired schematically; ENTSO-E marks Under Construction; OSM tags construction.","gap":"not_published","gap_note":"No open national GIS vector dataset tracks operational status for both transmission and distribution lines; distribution status is unpublished as open GIS."}]},"sources":[{"source_id":"s001","name":"IGN Base Topográfica Nacional (BTN) — 0710L Línea eléctrica (Vector Tiles API & CNIG Download)","publisher":"Instituto Geográfico Nacional (IGN) / Centro Nacional de Información Geográfica (CNIG)","official":true,"landing_url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","data_url":"https://vt-btn.idee.es/1.0.0/btn/tile/{z}/{y}/{x}.pbf","access":"api","format":"MVT (.pbf); GeoPackage (.gpkg) & Shapefile (.shp) on CNIG portal","license":"CC BY 4.0","language":"es","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Official national 1:2,000-1:25,000 topographic vector geometries and banded voltage (TENSI_0710) for overhead power lines across all of Spain.","first_seen_pass":1,"rank":1,"summary":"IGN Base Topográfica Nacional (BTN) — 0710L Línea eléctrica (Vector Tiles API & CNIG Download)","coverage_note":"All of Spain (Peninsula, Illes Balears, Canarias, Ceuta, Melilla)","data_date":"2026-07-27 (MVT snapshot 20260723_docker_des / layer poligonoTile27072026; spaignmvt_BTN metadata 2025-12-22; feature f_alta dates up to 2024-2026)","caveats":["Consult the main caveats and the complete reading traps and access evidence in the detail."],"coverage":{"geographic":"All of Spain (Peninsula, Illes Balears, Canarias, Ceuta, Melilla)"},"fine_print":{"unit":{"value":"kV (kilovolts, 4 code-list bands in TENSI_0710: 01 <100 kV, 02 100-150 kV, 03 220 kV, 04 400 kV)","quote":"Indica la tensión eléctrica en KV que soporta el tendido y para el cual está destinado: 01 < 100 KV, 02 100-150 KV, 03 220 KV, 04 400 KV","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","attempts":[]},"inclusion_rule":{"value":"Overhead electric cables supported by towers or poles captured at 1:2,000-1:7,000 work scale (1:2,000-1:25,000 database) with <3 m positional accuracy, connecting tower bases to substations, transformers or power plants.","quote":"Las entidades que se recogen para este fenómeno son elementos lineales continuos que recogen la proyección de la línea sobre el terreno, y deben capturarse mediante tramos rectos registrando un vértice en la base de cada una de las torres eléctricas del tendido","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","attempts":[]},"reference_date":{"value":"2026-07-27 (MVT snapshot 20260723_docker_des / layer poligonoTile27072026; spaignmvt_BTN metadata 2025-12-22; feature f_alta dates up to 2024-2026)","quote":"20260723_docker_des","url":"https://vt-btn.idee.es/datos/snapshot.txt","attempts":[]},"update_frequency":{"value":"Monthly","quote":"Todas las actualizaciones que se producen en la Base Topográfica Nacional serán publicadas en los ficheros a descarga afectados (BTN, BTN-POI) y en los servicios web con una periodicidad mensual.","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","attempts":[]},"exclusions":{"value":"Excludes all underground and submarine cables (lines end at transition tower), lacks operator and operational status attributes, and omits low-voltage urban lines not captured via photogrammetry/regional BTA.","quote":"Cuando una línea eléctrica se soterra, se captura una torra de alta tensión en el punto final de la línea, y no se captura el tramo subterráneo.","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","attempts":[]}},"key_fields":[{"field":"id","meaning":"BTN persistent feature identifier"},{"field":"tensi_0710","meaning":"Voltage band string ('01 < 100 kV', '02 100-150 kV', '03 220 kV', '04 400 kV')"},{"field":"f_alta","meaning":"Date element was added or last modified in BTN (YYYY/MM/DD)"}],"how_to_use":{"example_request":"curl -sL 'https://vt-btn.idee.es/1.0.0/btn/tile/14/6361/8022.pbf' -o caparacena_z14.pbf","example_result":"MVT layer btn0710l_lin_elec (12 features in tile 14/6361/8022); decoded sample: {'id': None, 'tensi_0710': '03 220 kV', 'f_alta': '2024/09/16'} with LineString coordinates [[-3.725331, 37.26741], [-3.724515, 37.26753], [-3.713036, 37.267684]].","steps":["Fetch TileJSON metadata at https://vt-btn.idee.es/1.0.0/btn/metadata.json to confirm layer schema and zoom bounds (btn0710l_lin_elec starts at minzoom 13.5305, so request zoom 14, 15 or 16).","Compute XYZ Web Mercator tile indices for the Spanish area of interest and download https://vt-btn.idee.es/1.0.0/btn/tile/{z}/{y}/{x}.pbf (note: path order is z/y/x, not z/x/y!).","Decode the uncompressed Protocol Buffer MVT layer 'btn0710l_lin_elec' (e.g. with Python mapbox-vector-tile or GDAL/OGR) and merge line segments clipped across tile borders by geometry/tensi_0710.","Alternatively, for unclipped national GeoPackage (BTN_T_Energia.gpkg) or provincial Shapefiles, use an interactive browser at https://centrodedescargas.cnig.es/CentroDescargas/btn (the CNIG download portal drops automated HTTP clients)."],"reading_traps":["MVT URL order is /{z}/{y}/{x}.pbf (latitude/row y before longitude/column x), reversed from typical /{z}/{x}/{y} tile schemes.","btn0710l_lin_elec only appears at zoom >= 14 (minzoom 13.5305) and tiles with no overhead lines omit the layer entirely.","tensi_0710 groups all distribution voltages below 100 kV into '01 < 100 kV' and 110/132/150 kV into '02 100-150 kV'; exact kV is unavailable.","Underground and submarine cables are completely absent because BTN stops overhead lines at the transition tower.","Tile geometries are clipped at tile boundaries and integer-quantized to 4096 extent."]},"test":{"tested_on":"2026-11-16","method":"api_query","http_status":200,"content_type":"application/octet-stream (MVT PBF); text/html empty reply on CNIG download portal","size_bytes":27773,"records_total":null,"records_for_country":null,"problems":["Secondary direct-download portal https://centrodedescargas.cnig.es/CentroDescargas/btn rejects automated HTTP clients with empty reply (curl error 52 via BigIP)."]},"evidence":[{"claim":"Layer btn0710l_lin_elec schema and zoom range on vt-btn.idee.es","url":"https://vt-btn.idee.es/1.0.0/btn/metadata.json","quote":"\"id\": \"btn0710l_lin_elec\", \"minzoom\": 13.5305, \"maxzoom\": 19, \"fields\": {\"id\": \"Number\", \"tensi_0710\": \"String\", \"f_alta\": \"String\"}"},{"claim":"Excludes underground segments and defines voltage code list and monthly update schedule","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","quote":"Cuando una línea eléctrica se soterra, se captura una torra de alta tensión en el punto final de la línea, y no se captura el tramo subterráneo."},{"claim":"CC BY 4.0 license and national GeoPackage filename BTN_T_Energia","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","quote":"BTN Tema - Energía | BTN_T_Energia"}],"members":[],"members_summary":null},{"source_id":"s002","name":"Andalucía MIEA — Líneas Eléctricas (Agencia Andaluza de la Energía WFS)","publisher":"Agencia Andaluza de la Energía (Junta de Andalucía)","official":true,"landing_url":"https://www.agenciaandaluzadelaenergia.es/es/informacion-energetica/cartografia-energetica-de-andalucia/servicio-wms-infraestructura-energetica-de-andalucia","data_url":"https://www.agenciaandaluzadelaenergia.es/mapwms/wfs","access":"api","format":"WFS 2.0.0 (GeoJSON, GML 3.2)","license":"unknown","language":"es","has_coordinates":true,"location_precision":"exact","publisher_type":"regional_government","adds":"Official energy-agency GIS providing exact kV voltage (50, 66, 132, 220, 400 kV) and operator/owner (PROPIETARIO) for transmission and high-voltage distribution across Andalucía.","first_seen_pass":1,"rank":2,"summary":"Andalucía MIEA — Líneas Eléctricas (Agencia Andaluza de la Energía WFS)","coverage_note":"Andalucía (8 provinces, southern Spain)","data_date":"2025-12-31","caveats":["Consult the main caveats and the complete reading traps and access evidence in the detail."],"coverage":{"geographic":"Andalucía (8 provinces, southern Spain)"},"fine_print":{"unit":{"value":"kV (string e.g. '400 kV', '220 kV', '132 kV', '66 kV', '50 kV')","quote":"Capa que contiene los trazados de las líneas eléctricas de transporte (400 kV y 220 kV) y de distribución (132 kV, 66 kV y 50 kV).","url":"https://www.ideandalucia.es/catalogo/inspire/srv/api/records/ac76afe7-6129-493f-ab16-b5be5580b449","attempts":[]},"inclusion_rule":{"value":"Existing electricity transmission lines (220, 400 kV) and high-voltage distribution lines (50, 66, 132 kV) in Andalucía.","quote":"Capa que contiene los trazados de las líneas eléctricas de transporte (400 kV y 220 kV) y de distribución (132 kV, 66 kV y 50 kV).","url":"https://www.ideandalucia.es/catalogo/inspire/srv/api/records/ac76afe7-6129-493f-ab16-b5be5580b449","attempts":[]},"reference_date":{"value":"2025-12-31","quote":"Información referida a plantas de generación eléctrica actualizada a 30 de junio de 2026. Resto de infraestructuras a 31 de diciembre de 2025.","url":"https://www.agenciaandaluzadelaenergia.es/es/informacion-energetica/cartografia-energetica-de-andalucia/servicio-wms-infraestructura-energetica-de-andalucia","attempts":[]},"update_frequency":{"value":"Semi-annual","quote":"La información se actualiza semestralmente y se publica en los servicios web WMS y WFS","url":"https://www.ideandalucia.es/catalogo/inspire/srv/api/records/ac76afe7-6129-493f-ab16-b5be5580b449","attempts":[]},"exclusions":{"value":"Regional scope (Andalucía only); omits medium/low-voltage distribution (<50 kV), lacks operational status field, and groups minor local DSOs under 'Pequeña distribuidora'.","quote":"Capa que contiene los trazados de las líneas eléctricas de transporte (400 kV y 220 kV) y de distribución (132 kV, 66 kV y 50 kV).","url":"https://www.ideandalucia.es/catalogo/inspire/srv/api/records/ac76afe7-6129-493f-ab16-b5be5580b449","attempts":[]}},"key_fields":[{"field":"NOMBRE","meaning":"Line name / identifier"},{"field":"TENSION","meaning":"Exact nominal voltage string ('50 kV', '66 kV', '132 kV', '220 kV', '400 kV')"},{"field":"PROPIETARIO","meaning":"Operator/owner ('E-Distribución Redes Digitales', 'Red Eléctrica', 'Pequeña distribuidora')"}],"how_to_use":{"example_request":"https://www.agenciaandaluzadelaenergia.es/mapwms/wfs?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetFeature&TYPENAMES=MIEA:LineasElect&outputFormat=application/json&srsName=EPSG:4326","example_result":"FeatureCollection with 899 MultiLineString features (all 899 verified inside Andalucía bbox [-8.0, 35.8, -1.2, 38.9]): e.g. id='LineasElect.1', coordinates [[[-7.26023116, 37.48824684], ...]]. Counts: 66 kV (574), 132 kV (162), 220 kV (108), 400 kV (48), 50 kV (7); E-Distribución Redes Digitales (727), Red Eléctrica (158), Pequeña distribuidora (14).","steps":["Request WFS GetCapabilities at https://www.agenciaandaluzadelaenergia.es/mapwms/wfs?Request=GetCapabilities&SERVICE=WFS&VERSION=2.0.0 and locate layer MIEA:LineasElect.","Fetch all 899 features in a single request using outputFormat=application/json and srsName=EPSG:4326 (default CRS is projected meters EPSG:25830).","Filter by PROPIETARIO ('Red Eléctrica' for transmission vs 'E-Distribución Redes Digitales' / 'Pequeña distribuidora' for distribution) and TENSION."],"reading_traps":["Default WFS geometry coordinates are projected in ETRS89 UTM Zone 30N (EPSG:25830); specify srsName=EPSG:4326 for lon/lat.","Does not include medium- or low-voltage distribution lines below 50 kV (e.g. 20 kV, 15 kV, 0.4 kV).","Small local distributors (14 features) are anonymized as 'Pequeña distribuidora' rather than named individually.","No status attribute; represents existing infrastructure as of 2025-12-31."]},"test":{"tested_on":"2026-11-16","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":null,"records_total":899,"records_for_country":899,"problems":[]},"evidence":[{"claim":"Covers 400/220 kV transmission and 132/66/50 kV distribution, updated semi-annually via WFS","url":"https://www.ideandalucia.es/catalogo/inspire/srv/api/records/ac76afe7-6129-493f-ab16-b5be5580b449","quote":"Capa que contiene los trazados de las líneas eléctricas de transporte (400 kV y 220 kV) y de distribución (132 kV, 66 kV y 50 kV). La información se actualiza semestralmente y se publica en los servicios web WMS y WFS"},{"claim":"Official WFS URL and infrastructure reference date 2025-12-31","url":"https://www.agenciaandaluzadelaenergia.es/es/informacion-energetica/cartografia-energetica-de-andalucia/servicio-wms-infraestructura-energetica-de-andalucia","quote":"Resto de infraestructuras a 31 de diciembre de 2025."}],"members":[],"members_summary":null},{"source_id":"s003","name":"Spanish Regional Geoportals (Partial Topographic BTA, Avifauna RD 1432/2008 & Renewable Evacuation Layers)","publisher":"Regional governments / IDEs of Spain (La Rioja, País Vasco, Comunitat Valenciana, Canarias, Cantabria, plus checked non-line portals)","official":true,"landing_url":"https://ogc.larioja.org/wfs/request.php?SERVICE=WFS&REQUEST=GetCapabilities","data_url":"https://ogc.larioja.org/wfs/request.php?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetFeature&TYPENAMES=bta:f_0116_tendido_lineas&CQL_FILTER=TIPO_0116%3D%27el%C3%A9ctrico%27&outputFormat=application/json&srsName=EPSG:4326","access":"api","format":"WFS (GeoJSON/GML), Shapefile (.zip), ArcGIS REST","license":"CC BY 4.0 / regional open data terms","language":"es","has_coordinates":true,"location_precision":"exact","publisher_type":"regional_government","adds":"Regional official line geometries outside Andalucía, including La Rioja BTA lines (4,788 electric features), País Vasco RD 1432/2008 lines with exact kV (161 features), Comunitat Valenciana PV evacuation lines with operational/construction status, La Palma PIOLP HV lines, and Cantabria wind/BESS evacuation lines.","first_seen_pass":1,"rank":3,"summary":"Spanish Regional Geoportals (Partial Topographic BTA, Avifauna RD 1432/2008 & Renewable Evacuation Layers)","coverage_note":"Selected regions of Spain only (out of 17 CCAA + 2 autonomous cities: 1 full HV grid in Rank 2, 5 partial line layers here, 9 checked with no general grid line WFS, 4 sampled/unreachable)","data_date":"Varies by region (País Vasco 2015/2018; La Palma 2007/2015; València/Cantabria/La Rioja active)","caveats":["Consult the main caveats and the complete reading traps and access evidence in the detail."],"coverage":{"geographic":"Selected regions of Spain only (out of 17 CCAA + 2 autonomous cities: 1 full HV grid in Rank 2, 5 partial line layers here, 9 checked with no general grid line WFS, 4 sampled/unreachable)"},"fine_print":{"unit":{"value":"Qualitative ('alta', 'media') in La Rioja BTA; kV in País Vasco and Comunitat Valenciana","quote":"TIPO_0116\":\"eléctrico\",\"TENSI_0116\":\"alta\"","url":"https://ogc.larioja.org/wfs/request.php?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetCapabilities","attempts":[]},"inclusion_rule":{"value":"Varies by region: topographic overhead lines (La Rioja BTA), RD 1432/2008 bird-protection lines (País Vasco), or wind/PV/BESS evacuation lines (València, Cantabria).","quote":"Para minimizar los efectos negativos que dichas infraestructuras ocasionan sobre las aves se publicó el Real Decreto 1432/2008","url":"https://www.geo.euskadi.eus/geonetwork/srv/spa/csw?SERVICE=CSW&VERSION=2.0.2&REQUEST=GetRecordById&outputSchema=http://www.isotc211.org/2005/gmd&ElementSetName=full&ID=md_IDEEu_AVES_LINEASE_es","attempts":[]},"reference_date":{"value":"Varies by region (País Vasco 2015/2018; La Palma 2007/2015; València/Cantabria/La Rioja active)","quote":"'INVENTARIO': '2015 y 2018'","url":"https://www.geo.euskadi.eus/cartografia/DatosDescarga/Medio_Ambiente/Aves_y_Lineas_Electricas/KM_LINEAS_ASIGNADASAvesTendidos.zip","attempts":[]},"update_frequency":{"value":"Irregular / 3 years in Catalonia PCC catalog (partial public access)","quote":"Acceso: Parcialmente público Periodicidad de actualización: 3 años","url":"https://www.cccartografica.cat/es/Tenemos-un-Plan/Que-geoinformacion-recoge-el-PCC/Catalogo-del-PCC-2022/Servicios-de-utilidad-publica-y-estatales/Red-de-lineas-electricas","attempts":[]},"exclusions":{"value":"9 checked regions lacked open general power-line vector downloads/WFS (Aragón, Asturias, Illes Balears, Castilla y León, Cataluña, Galicia, Madrid, Murcia, Navarra); 4 territories (Castilla-La Mancha, Extremadura, Ceuta, Melilla) yielded 0 datasets in datos.gob.es API and failed DNS/unchecked.","quote":"Acceso: Parcialmente público","url":"https://www.cccartografica.cat/es/Tenemos-un-Plan/Que-geoinformacion-recoge-el-PCC/Catalogo-del-PCC-2022/Servicios-de-utilidad-publica-y-estatales/Red-de-lineas-electricas","attempts":[]}},"key_fields":[{"field":"TIPO_0116 / TENSI_0116","meaning":"La Rioja BTA line type ('eléctrico') and qualitative voltage ('alta', 'media', 'sin clasificar')"},{"field":"TENS / NOMBRE_IBD","meaning":"País Vasco RD 1432/2008 exact voltage (e.g. '13,2 KV') and line name"},{"field":"tension_kv / tipo","meaning":"Comunitat Valenciana PV evacuation line voltage (kV) and underground/overhead type"}],"how_to_use":{"example_request":"https://ogc.larioja.org/wfs/request.php?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetFeature&TYPENAMES=bta:f_0116_tendido_lineas&CQL_FILTER=TIPO_0116%3D%27el%C3%A9ctrico%27&COUNT=2&outputFormat=application/json&srsName=EPSG:4326","example_result":"FeatureCollection with numberMatched=4788 (100/100 sampled coordinates inside La Rioja bbox [-3.3, 41.8, -1.6, 42.8]): e.g. id='f_0116_tendido_lineas.fid-27dae327_1a1dc64718d_4087', properties={'ID': 106812, 'TIPO_0116': 'eléctrico', 'TENSI_0116': 'alta'}.","steps":["Query each regional member individually using its listed WFS/ArcGIS/download URL; there is no unified regional endpoint.","In La Rioja WFS, filter bta:f_0116_tendido_lineas with CQL_FILTER=TIPO_0116='eléctrico' to exclude telecom cables.","In Comunitat Valenciana ICV WFS, query both ms:Explotacion.LineasEvacuacion.GVA and ms:AAConstruccion.LineasEvacuacion.GVA, noting these are PV evacuation spurs only."],"reading_traps":["Several regional layers titled 'líneas eléctricas' (Navarra BIODIV_Pol_ImpElecAvi, Castilla y León avifau_cyl_prot_laat, Aragón RD 1432/2008, Cantabria layer 60) contain polygon bird-protection zones, not line geometries.","La Rioja bta:f_0116_tendido_lineas mixes telecom and electric lines unless filtered on TIPO_0116='eléctrico', and TENSI_0116 is qualitative ('alta'/'media') with no operator.","Cataluña PCC explicitly marks general power-line data 'Parcialmente público'."]},"test":{"tested_on":"2026-11-16","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":null,"records_total":4788,"records_for_country":4788,"problems":["Regional coverage is fragmented: most Autonomous Communities do not publish full transmission/distribution line geometries."]},"evidence":[{"claim":"La Rioja BTA WFS exposes 4,788 electric line features","url":"https://ogc.larioja.org/wfs/request.php?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetCapabilities","quote":"bta:f_0116_tendido_lineas"},{"claim":"Catalonia PCC states electric line network access is only partially public","url":"https://www.cccartografica.cat/es/Tenemos-un-Plan/Que-geoinformacion-recoge-el-PCC/Catalogo-del-PCC-2022/Servicios-de-utilidad-publica-y-estatales/Red-de-lineas-electricas","quote":"Acceso: Parcialmente público"}],"members":[{"name":"La Rioja — IDERioja WFS (bta:f_0116_tendido_lineas)","landing_url":"https://datos.gob.es/apidata/catalog/dataset/a17002943-lineas-electricas-de-alta-tension-en-zonas-de-proteccion.json","data_url":"https://ogc.larioja.org/wfs/request.php?SERVICE=WFS&VERSION=2.0.0&REQUEST=GetFeature&TYPENAMES=bta:f_0116_tendido_lineas&CQL_FILTER=TIPO_0116%3D%27el%C3%A9ctrico%27&outputFormat=application/json&srsName=EPSG:4326","access":"api","tested":true,"data_found":null,"note":"Tested WFS 2.0.0: 4,788 electric line segments (5,016 total incl. telecom/unclassified). Qualitative TENSI_0116 ('alta', 'media', 'sin clasificar') only; no operator or status. Separate avifauna portal download timed out."},{"name":"País Vasco / Euskadi — GeoEuskadi Avifauna & Tendidos Eléctricos (RD 1432/2008)","landing_url":"https://www.geo.euskadi.eus/geonetwork/srv/spa/csw?SERVICE=CSW&VERSION=2.0.2&REQUEST=GetRecordById&outputSchema=http://www.isotc211.org/2005/gmd&ElementSetName=full&ID=md_IDEEu_AVES_LINEASE_es","data_url":"https://www.geo.euskadi.eus/cartografia/DatosDescarga/Medio_Ambiente/Aves_y_Lineas_Electricas/KM_LINEAS_ASIGNADASAvesTendidos.zip","access":"direct_download","tested":true,"data_found":null,"note":"Tested Shapefile (110 KB): 161 polyline features only in bird-protection zones (inventories 2015/2018); has exact TENS (e.g. '13,2 KV') and NOMBRE_IBD, no operator or status."},{"name":"Comunitat Valenciana — ICV WFS Instalaciones Fotovoltaicas (Líneas de evacuación)","landing_url":"https://dadesobertes.gva.es/api/3/action/package_search?q=electrica&rows=10","data_url":"https://terramapas.icv.gva.es/2601_Fotovoltaicas?service=WFS&version=2.0.0&request=GetFeature&typeNames=ms:Explotacion.LineasEvacuacion.GVA&outputFormat=application/json;%20subtype=geojson","access":"api","tested":true,"data_found":null,"note":"Tested WFS: covers solar PV evacuation lines only (not general transmission/distribution grid). Includes tension_kv, tipo (overhead/underground), and status split across Explotacion vs AAConstruccion layers."},{"name":"Canarias (La Palma) — PIOLP Energía ArcGIS FeatureServer (linea electrica at)","landing_url":"https://hub.arcgis.com/maps/ba2171ed78b3431aa8a95fe055bc1cdf","data_url":"https://services.arcgis.com/hkQNLKNeDVYBjvFE/arcgis/rest/services/PIOLP_Energia/FeatureServer/8","access":"api","tested":true,"data_found":null,"note":"Tested FeatureServer/8: only 2 HV polyline features on La Palma with OBJECTID, FID_, Shape__Length; no voltage, operator, or status."},{"name":"Canarias (Gran Canaria) — IDEGranCanaria Visor Sistema Eléctrico","landing_url":"https://visor.idegrancanaria.es/default.php?svc=svcSistElectrico","data_url":null,"access":"web_viewer_only","tested":false,"data_found":null,"note":"Web viewer for Gran Canaria electricity system (svcSistElectrico_lel layer); GRAFCAN ServicioWFS/Energia returned 404 and idecanarias.es/listado_servicios lists WMS only."},{"name":"Cantabria — Geoservicios Energía MapServer","landing_url":"https://geoservicios.cantabria.es/inspire/rest/services/Energia/MapServer?f=json","data_url":"https://geoservicios.cantabria.es/inspire/rest/services/Energia/MapServer","access":"api","tested":true,"data_found":null,"note":"Tested REST metadata: layers 5, 13, 20, 26, 32, 40, 48, 56 cover wind-farm and BESS evacuation polylines only; layer 60 is avifauna protection polygons; no general grid."}],"members_summary":{"total":null,"listed":6,"tested":5,"data_found":0,"scope_note":"Inherited members; data findings were not reclassified during this structural migration. Consult each member note.","pattern":null},"member_scope":{"total":null,"note":"Inherited members; data findings were not reclassified during this structural migration. Consult each member note.","pattern":null}},{"source_id":"s004","name":"OpenStreetMap Power Grid (OpenInfraMap Vector Tiles & Geofabrik Extracts)","publisher":"OpenStreetMap contributors / OpenInfraMap / Geofabrik","official":false,"landing_url":"https://openinframap.org/stats/area/Spain","data_url":"https://openinframap.org/map/power/{z}/{x}/{y}.pbf","access":"api","format":"MVT (.pbf); full country OSM PBF (.osm.pbf) at Geofabrik","license":"ODbL 1.0","language":"mul","has_coordinates":true,"location_precision":"exact","publisher_type":"community","adds":"Nationwide open crowdsourced geometries including underground/submarine cables (power=cable), exact voltage in kV where tagged (80.5% of mapped length), partial operator tags, and construction/disused status.","first_seen_pass":1,"rank":4,"coverage":{"geographic":"All of Spain (note: Geofabrik europe/spain-latest.osm.pbf excludes Canary Islands, served separately under africa/canary-islands-latest.osm.pbf; OpenInfraMap tiles include all Spain)"},"fine_print":{"unit":{"value":"V (volts) in raw OSM voltage=* tags; kV (float) in OpenInfraMap power_line tile layer","quote":"10 kV – 24 kV 24,166 km 18.8% ... 330 kV – 549 kV 15,201 km 11.8% ... Total 128,460 km","url":"https://openinframap.org/stats/area/Spain","attempts":[]},"inclusion_rule":{"value":"Crowdsourced overhead transmission (power=line), minor distribution (power=minor_line) and underground/submarine cables (power=cable) mapped by OSM contributors.","quote":"Spain has 5216 power plants totalling 101,267 MW and 128,460 km of power lines mapped on OpenStreetMap.","url":"https://openinframap.org/stats/area/Spain","attempts":[]},"reference_date":{"value":"2026-11-15","quote":"Stats updated 2026-11-15","url":"https://openinframap.org/stats/area/Spain","attempts":[]},"update_frequency":{"value":"Daily (Geofabrik extracts & OpenInfraMap stats); continuous on OSM","quote":"contains all OSM data up to 2026-11-15T21:22:28Z. File size: 1.4 GB.","url":"https://download.geofabrik.de/europe/spain.html","attempts":[]},"exclusions":{"value":"Unofficial and incomplete: 19.5% (25,053 km) lacks voltage tags; ~85% of lines in tested Madrid/Granada samples lack operator tags; 31,218 km mapped at >=220 kV vs REE's >46,000 km circuits; sparse LV/MV urban underground distribution.","quote":"No voltage tagged 25,053 km 19.5%","url":"https://openinframap.org/stats/area/Spain","attempts":[]}},"key_fields":[{"field":"type","meaning":"OSM power tag ('line', 'minor_line', 'cable')"},{"field":"voltage","meaning":"Nominal voltage in kV (float in OIM tiles; Volts in raw OSM PBF)"},{"field":"operator","meaning":"Network operator name (e.g. 'Red Eléctrica de España', 'Endesa')"},{"field":"construction / disused","meaning":"Boolean status flags (from construction:power=* / disused:power=*)"},{"field":"location","meaning":"Placement tag (e.g. 'underground')"}],"how_to_use":{"example_request":"curl -sL 'https://openinframap.org/map/power/12/2005/1590.pbf' -o oim_z12.pbf","example_result":"MVT layer power_line (170 features in tile 12/2005/1590 near Caparacena: 162 with voltage, 25 with operator, 0 construction); sample: {'osm_id': 1385729176, 'name': 'Línea de alta tensión Caparacena - Fargue', 'operator': 'Red Eléctrica de España', 'voltage': 220.0, 'type': 'line', 'construction': False, 'circuits': 1, 'coords[:2]': [[-3.725352, 37.267291], [-3.724387, 37.267359]]}.","steps":["For bulk nationwide vector analysis without tile clipping, download spain-latest.osm.pbf (1.5 GB, >100 MB) and africa/canary-islands-latest.osm.pbf (60.5 MB) from Geofabrik and filter ways/relations with power in (line, minor_line, cable) or construction:power=* using osmium-tool.","For lightweight regional API queries, fetch MVT tiles from https://openinframap.org/map/power/{z}/{x}/{y}.pbf (layer 'power_line') or count/query historical coverage via https://api.ohsome.org/v1/elements/count.","Note that raw OSM ways store voltage in Volts separated by semicolons for multi-voltage lines (e.g. '220000;132000'), whereas OpenInfraMap tiles convert voltage to kV floats."],"reading_traps":["Geofabrik spain-latest.osm.pbf omits the Canary Islands (listed separately at africa/canary-islands-latest.osm.pbf).","In tested samples, operator was missing on 85.3% of lines in tile 12/2005/1590 (25/170) and 85.8% of power=line ways in Madrid (33/232 via Ohsome, 0/173 for minor_line).","Overpass API mirrors (overpass-api.de, kumi.systems, private.coffee, maps.mail.ru) failed to connect or timed out during testing; use Geofabrik PBF or OpenInfraMap MVT tiles instead.","Compare OSM lengths carefully against REE: OSM maps physical tower corridors (1 way for a double-circuit line), whereas REE counts circuit-km (>46,000 km)."]},"test":{"tested_on":"2026-11-16","method":"api_query","http_status":200,"content_type":"application/x-protobuf (OIM MVT); application/octet-stream (Geofabrik 1,502,298,195 bytes headers_only)","size_bytes":14538,"records_total":128460,"records_for_country":128460,"problems":["Overpass API endpoints timed out or refused connection; verified via OpenInfraMap MVT tiles, OpenInfraMap Spain stats, Ohsome count API (Madrid bbox), and Geofabrik HEAD check."]},"evidence":[{"claim":"128,460 km of power lines mapped in Spain with voltage breakdown and 19.5% untagged","url":"https://openinframap.org/stats/area/Spain","quote":"Spain has 5216 power plants totalling 101,267 MW and 128,460 km of power lines mapped on OpenStreetMap."},{"claim":"Geofabrik Spain extract size (1.4 GiB) and exclusion of Canary Islands","url":"https://download.geofabrik.de/europe/spain.html","quote":"Note The Canary Islands are listed separately here ... File size: 1.4 GB."}],"members":[],"members_summary":null},{"source_id":"s005","name":"ENTSO-E Transmission System Grid Map (ArcGIS FeatureServer & PDF Maps)","publisher":"ENTSO-E (European Network of Transmission System Operators for Electricity)","official":true,"landing_url":"https://www.entsoe.eu/data/map/","data_url":"https://services-eu1.arcgis.com/kkoySFboPZ70Z0Od/arcgis/rest/services/Grid_Map_view/FeatureServer/1","access":"api","format":"ArcGIS FeatureServer (JSON / GeoJSON); PDFs on downloads page","license":"unknown","language":"en","has_coordinates":true,"location_precision":"none","publisher_type":"supranational","adds":"Official TSO-association layer distinguishing existing vs Under Construction transmission lines (132-150, 220, 380-400 kV) and underground cables across Peninsula, Baleares and Canarias, though with schematized non-exact coordinates.","first_seen_pass":1,"rank":5,"coverage":{"geographic":"Continental Europe + Canary Islands (includes Spain: >2,000 edges in Peninsula/Balearics bbox + 5 in Canarias bbox)"},"fine_print":{"unit":{"value":"kV (string classes in Symbol field: '132-150 kV', '220 kV', '380-400 kV')","quote":"The map shows existing elements and those under construction: power plants, converters, substations and high-voltage cables/lines.","url":"https://www.entsoe.eu/data/map/","attempts":[]},"inclusion_rule":{"value":"Transmission network elements (>=220 kV plus 132-150 kV island/interconnection lines) operated by ENTSO-E members (REE in Spain).","quote":"This map is a comprehensive illustration of the transmission system network operated by members of the European Network of Transmission System Operators.","url":"https://www.entsoe.eu/data/map/","attempts":[]},"reference_date":{"value":"2024-11-20 (PDF downloads); FeatureServer Edge dataLastEditDate timestamp present (live service)","quote":"Downloads updated on 20 th November 2024","url":"https://www.entsoe.eu/data/map/downloads/","attempts":[]},"update_frequency":{"value":"Annual PDF releases (2019, 2023, 2024); periodic FeatureServer edits","quote":"Downloads updated on 20 th November 2024","url":"https://www.entsoe.eu/data/map/downloads/","attempts":[]},"exclusions":{"value":"Schematized locations only ('not located at their exact geographic location'); excludes distribution lines (<132 kV) and lacks an operator attribute or line ID/name.","quote":"Network elements are not located at their exact geographic location.","url":"https://www.entsoe.eu/data/map/","attempts":[]}},"key_fields":[{"field":"OBJECTID","meaning":"Feature ID"},{"field":"Symbol","meaning":"Combined voltage, status, circuit count and underground class (e.g. '220 kV Transmission Line Under Construction, 1 Circuit')"}],"how_to_use":{"example_request":"https://services-eu1.arcgis.com/kkoySFboPZ70Z0Od/arcgis/rest/services/Grid_Map_view/FeatureServer/1/query?where=1%3D1&geometry=-10,35,5,44&geometryType=esriGeometryEnvelope&inSR=4326&spatialRel=esriSpatialRelIntersects&outFields=*&resultRecordCount=3&f=geojson","example_result":"FeatureCollection (2006 features matched in Peninsula+Balearics bbox, exceededTransferLimit=true; 5 features in Canarias bbox): e.g. {'OBJECTID': 4, 'Symbol': '132-150 kV Transmission Line, 1 Circuit'} with coordinates [[1.42204, 38.91401], [1.45294, 38.97809], [1.49345, 38.98343]].","steps":["Query Edge layer (ID 1) at Grid_Map_view/FeatureServer/1/query using bounding boxes for Peninsula/Balearics (-10,35,5,44) and Canary Islands (-19,27,-13,30).","Paginate with resultOffset (maxRecordCount=1000; 2,006 matches in mainland bbox, note bbox also overlaps Portugal/southern France so clip to Spain).","Parse voltage tier, circuit count, underground flag, and status ('Under Construction' vs existing) from the Symbol string."],"reading_traps":["CRITICAL: ENTSO-E explicitly states geometries are schematized and NOT exact physical routes; do not use for spatial proximity or tower-level routing.","Layer 1 has only OBJECTID and Symbol — no country code, no line name, and no operator field.","Bounding box queries include neighboring Portugal and France lines; spatial clipping to Spanish borders is required."]},"test":{"tested_on":"2026-11-16","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":null,"records_total":null,"records_for_country":2011,"problems":["Geometries are schematized rather than true physical routes; record count (2006 mainland + 5 Canarias) is bbox-based and includes border overlap with Portugal/France."]},"evidence":[{"claim":"ENTSO-E warns coordinates are not exact geographic locations and lists covered features","url":"https://www.entsoe.eu/data/map/","quote":"Network elements are not located at their exact geographic location. The map shows existing elements and those under construction: power plants, converters, substations and high-voltage cables/lines."},{"claim":"PDF downloads page with update date","url":"https://www.entsoe.eu/data/map/downloads/","quote":"Downloads updated on 20 th November 2024"}],"members":[],"members_summary":null},{"source_id":"s006","name":"Red Eléctrica de España (REE) — Infored Portal (Official Line Information Requests)","publisher":"Red Eléctrica de España, S.A.U. (Redeia)","official":true,"landing_url":"https://www.ree.es/es/transporte-electricidad/red-transporte/nuestras-infraestructuras","data_url":"https://www.infored.ree.es/externo","access":"request_form","format":"Web portal request (internal GeoRED GIS backend)","license":"Proprietary / request-based","language":"es","has_coordinates":false,"location_precision":"none","publisher_type":"operator","adds":"Official transmission line location and affection data directly from Spain's sole statutory TSO for projects/works near REE lines, via individual request form.","first_seen_pass":1,"rank":6,"coverage":{"geographic":"All of Spain (REE transmission network: >46,000 km circuits)"},"fine_print":{"unit":{"value":"kV (400 kV and 220 kV mainland; 220, 132 and 66 kV Balearic and Canary Islands)","quote":"En España, la red de transporte funciona mayoritariamente a 400 kilovoltios (kV) y 220 kV en la Península, y a 220 kV, 132 kV y 66 kV en Baleares y Canarias.","url":"https://www.ree.es/es/transporte-electricidad/red","attempts":[]},"inclusion_rule":{"value":"Transmission grid facilities owned/operated by REE (>46,000 km circuits, >700 substations).","quote":"Está compuesta por más de 46.000 kilómetros de circuitos de líneas de alta tensión, más de 700 subestaciones y 6.000 posiciones y más de 225 transformadores.","url":"https://www.ree.es/es/transporte-electricidad/red","attempts":[]},"reference_date":{"value":null,"quote":null,"url":null,"attempts":["Checked https://www.ree.es/es/transporte-electricidad/red-transporte/nuestras-infraestructuras: states Infored portal purpose without dataset snapshot date.","Checked https://www.infored.ree.es/externo and main JS bundle: Cognito-authenticated request portal without public database release date."]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":["Checked https://www.ree.es/es/transporte-electricidad/red: describes operational grid without Infored GIS update cadence.","Checked https://georedservices.ree.es/arcgis/sharing/rest/search?q=*&f=json: returns 0 public catalog items."]},"exclusions":{"value":"Excludes generator step-up transformers, generation evacuation connection assets, private consumer lines, direct lines, and distribution networks (<220 kV mainland); no public bulk GIS download.","quote":"No forman parte de la red de transporte los transformadores de los grupos de generación, los elementos de conexión de dichos grupos a la red de transporte, las instalaciones de consumidores para su uso exclusivo y tampoco las líneas directas.","url":"https://www.ree.es/es/transporte-electricidad/red","attempts":[]}},"key_fields":[{"field":"Not publicly downloadable","meaning":"Internal GeoRED schema (observed in public 63-circuit sample Zonas_de_detalle_WEBREE_MIL1) includes CODIGO_BDI, NOMBRE, TENSION, ESTADO, PROPIETARIO1, EXPLOTADOR1, FEC_PTASER"}],"how_to_use":{"example_request":null,"example_result":"Did not register or submit a request form. Portal HTML loads Angular app with Amazon Cognito auth (inforedpro.auth.eu-west-1.amazoncognito.com) and GeoRED components.","steps":["Open https://www.infored.ree.es/externo (linked from REE Nuestras infraestructuras page).","Register/authenticate via Cognito and submit an external information request specifying the geographic area/project to obtain official line location/affection responses from REE."],"reading_traps":["No bulk national download is provided; portal is designed for site-specific infrastructure affection requests.","REE's public GeoRED MapServer (Zonas_de_detalle_WEBREE_MIL1) exposes only 63 overhead circuits and 18 underground segments across isolated detail zones, not the full >46,000 km grid."]},"test":{"tested_on":"2026-11-16","method":"page_only","http_status":200,"content_type":"text/html","size_bytes":905,"records_total":null,"records_for_country":null,"problems":["Requires user login/request submission via Cognito/Infored; full national transmission GIS is not publicly exposed."]},"evidence":[{"claim":"Infored is REE's official portal for requesting information on its transmission lines","url":"https://www.ree.es/es/transporte-electricidad/red-transporte/nuestras-infraestructuras","quote":"Información sobre nuestras instalaciones Portal para las solicitudes de información sobre las líneas propiedad de la compañía."},{"claim":"Transmission network exclusions and voltage levels","url":"https://www.ree.es/es/transporte-electricidad/red","quote":"En España, la red de transporte funciona mayoritariamente a 400 kilovoltios (kV) y 220 kV en la Península, y a 220 kV, 132 kV y 66 kV en Baleares y Canarias."}],"members":[],"members_summary":null},{"source_id":"s007","name":"MITECO Draft Transmission Development Plan 2025-2030 — Annex III Maps (PDF)","publisher":"Ministerio para la Transición Ecológica y el Reto Demográfico (MITECO)","official":true,"landing_url":"https://www.miteco.gob.es/es/energia/infraestructuras-integracion/infraestructuras.html","data_url":"https://www.miteco.gob.es/content/dam/miteco/es/energia/files-1/es-ES/Participacion/Documents/anexos/aeip-planificacion-h2030/4_Planficacion__ANEXO_III_-_MAPAS.pdf","access":"pdf","format":"PDF (13 pages, vector/embedded schematic maps)","license":"unknown","language":"es","has_coordinates":false,"location_precision":"none","publisher_type":"national_government","adds":"Official national schematic PDF maps (13 pages, Oct 2025) showing existing, baseline, proposed, and decommissioned ('Baja') transmission lines (400, 220, 132 kV, DC) across Peninsula, Baleares, and Canarias.","first_seen_pass":1,"rank":7,"coverage":{"geographic":"All of Spain (Peninsular, Balearic, and Canary Islands transmission systems)"},"fine_print":{"unit":{"value":"kV (400 kV, 220 kV, 132 kV, plus DC links 'c.c.')","quote":"Red existente: 400 kV 220 kV | Red de partida: 400 kV 220 kV 132 kV c.c.","url":"https://www.miteco.gob.es/content/dam/miteco/es/energia/files-1/es-ES/Participacion/Documents/anexos/aeip-planificacion-h2030/4_Planficacion__ANEXO_III_-_MAPAS.pdf","attempts":[]},"inclusion_rule":{"value":"Spanish transmission grid (existing, starting-point, proposed 2025-2030 developments, and decommissioned elements).","quote":"PROPUESTA DE DESARROLLO DE LA RDT DE ENERGÍA ELÉCTRICA. PERÍODO 2025-2030 ANEXO III – MAPAS","url":"https://www.miteco.gob.es/content/dam/miteco/es/energia/files-1/es-ES/Participacion/Documents/anexos/aeip-planificacion-h2030/4_Planficacion__ANEXO_III_-_MAPAS.pdf","attempts":[]},"reference_date":{"value":"2025-10-08 (PDF creation/modification date for 2025-2030 draft plan)","quote":"PROPUESTA DE PLAN DE DESARROLLO DE LA RED DE TRANSPORTE ELÉCTRICO 2025-2030","url":"https://www.miteco.gob.es/content/dam/miteco/es/energia/files-1/es-ES/Participacion/Documents/anexos/aeip-planificacion-h2030/4_Planficacion__ANEXO_III_-_MAPAS.pdf","attempts":[]},"update_frequency":{"value":"Every 6 years (statutory transmission planning cycle under Ley 24/2013 Art. 4.2)","quote":"El artículo 4.2 de la LSE dispone que la planificación eléctrica... abarcará periodos de seis años.","url":"https://www.miteco.gob.es/es/energia/infraestructuras-integracion/infraestructuras.html","attempts":[]},"exclusions":{"value":"Schematic cartography without georeferenced coordinates; covers transmission grid only (no distribution <220 kV mainland); draft proposal status for planned lines. (Note: REE also published an older 2017 PDF map at https://www.ree.es/sites/default/files/downloadable/mapa_lineas_2017_v1.pdf).","quote":"Adicionalmente, la planificación eléctrica incluye una parte vinculante correspondiente al desarrollo de la red de transporte de electricidad","url":"https://www.miteco.gob.es/es/energia/infraestructuras-integracion/infraestructuras.html","attempts":[]}},"key_fields":[{"field":"Legend categories","meaning":"Voltage (400 kV, 220 kV, 132 kV, c.c.) and status (Red existente, Red de partida, Red propuesta, Baja)"}],"how_to_use":{"example_request":"curl -sL 'https://www.miteco.gob.es/content/dam/miteco/es/energia/files-1/es-ES/Participacion/Documents/anexos/aeip-planificacion-h2030/4_Planficacion__ANEXO_III_-_MAPAS.pdf' -o miteco_anexo3.pdf # pages 2-13","example_result":"13-page PDF (5,605,577 bytes): page 2 Peninsular map + legend (Red existente / Red de partida / Red propuesta / Baja; 400/220/132 kV/c.c.), pages 3-8 regional zoom insets, pages 9-10 Balearic Islands, pages 11-13 Canary Islands.","steps":["Download 4_Planficacion__ANEXO_III_-_MAPAS.pdf directly from MITECO.","Inspect page 2 legend to distinguish Red existente vs Red de partida vs Red propuesta vs Baja, and use pages 3-13 for regional/island detail.","Cross-reference substation and line names with IGN BTN or OSM geometries since the PDF is schematic and lacks GIS georeferencing."],"reading_traps":["Line paths in the PDF are schematic straight/smoothed connectors between named substations, not exact physical routes.","Represents the draft 2025-2030 planning proposal; proposed lines ('Red propuesta') are not yet built or in service.","Note REE's older schematic PDF (mapa_lineas_2017_v1.pdf, Dec 2017) rejects HTTP HEAD with 403 Incapsula but downloads with HTTP 200 on GET."]},"test":{"tested_on":"2026-11-16","method":"download","http_status":200,"content_type":"application/pdf","size_bytes":5605577,"records_total":13,"records_for_country":13,"problems":[]},"evidence":[{"claim":"13-page PDF maps Peninsula, Baleares, and Canarias with existing/proposed/retired legend","url":"https://www.miteco.gob.es/content/dam/miteco/es/energia/files-1/es-ES/Participacion/Documents/anexos/aeip-planificacion-h2030/4_Planficacion__ANEXO_III_-_MAPAS.pdf","quote":"PROPUESTA DE PLAN DE DESARROLLO DE LA RED DE TRANSPORTE ELÉCTRICO 2025-2030 MAPA SISTEMA ELÉCTRICO PENINSULAR"},{"claim":"Statutory 6-year binding transmission planning cycle","url":"https://www.miteco.gob.es/es/energia/infraestructuras-integracion/infraestructuras.html","quote":"El artículo 4.2 de la LSE dispone que la planificación eléctrica... abarcará periodos de seis años."}],"members":[],"members_summary":null},{"source_id":"s008","name":"Inkolan — Multi-Utility Network Plans Platform (Electricity Distribution DWG)","publisher":"Inkolan (Agrupación de operadores de servicios públicos)","official":false,"landing_url":"https://www.inkolan.com/somos-inkolan/","data_url":"https://www.inkolan.com/Extranet/Extranet/wf_login.aspx","access":"paid","format":"DWG (ETRS89, layered by operator)","license":"Paid per-download / annual subscription","language":"es","has_coordinates":true,"location_precision":"exact","publisher_type":"commercial","adds":"Only consolidated Spanish source providing detailed underground and overhead distribution CAD plans (DWG in ETRS89) directly from the five largest electricity distribution groups (i-DE/Iberdrola, e-distribución/Endesa, UFD/Naturgy, Viesgo, E-REDES) for a fee.","first_seen_pass":1,"rank":8,"coverage":{"geographic":"Spain (territories served by member operators across all Autonomous Communities)"},"fine_print":{"unit":{"value":"Operator CAD symbology per layer (details not publicly documented without login/sample)","quote":"También te facilitamos en cada descarga la simbología específica de cada uno de nuestros operadores","url":"https://www.inkolan.com/informacion-tecnica/","attempts":[]},"inclusion_rule":{"value":"Underground and overhead utility networks (>1,220,000 km total across electricity, gas, telecom, water, municipal networks) submitted periodically by member operators.","quote":"Disponemos de más de 1.220.000 kms de canalizaciones ... Nuestros operadores nos envían sus redes periódicamente, para garantizar su actualización y calidad.","url":"https://www.inkolan.com/nuestro-servicio/","attempts":[]},"reference_date":{"value":null,"quote":null,"url":null,"attempts":["Checked https://www.inkolan.com/nuestro-servicio/: states operators submit networks periodically without giving exact date per utility.","Checked https://www.inkolan.com/informacion-tecnica/: states ETRS89 coordinate reference and DWG format without update timestamp."]},"update_frequency":{"value":"Periodic updates submitted by participating operators","quote":"Nuestros operadores nos envían sus redes periódicamente, para garantizar su actualización y calidad.","url":"https://www.inkolan.com/nuestro-servicio/","attempts":[]},"exclusions":{"value":"Paid commercial access (45.23 EUR per 1 ha example; 92 EUR/month single CCAA or 184 EUR/month all CCAA); covers participating operators only (~320 small non-member DSOs excluded); area-by-area CAD downloads rather than national bulk GIS export.","quote":"Ejemplo para una descarga de una superficie de 1 ha.: 45,23€ ... Cuota para todas las Comunidades Autónomas 184 €/mes","url":"https://www.inkolan.com/tarifas/","attempts":[]}},"key_fields":[{"field":"Operator CAD layers","meaning":"Networks organized in separate DWG layers by participating utility operator (Iberdrola, Endesa, UFD, Viesgo, E-REDES) in ETRS89"}],"how_to_use":{"example_request":null,"example_result":"Not downloaded (paid service requiring account registration and per-area payment).","steps":["Register an account at https://www.inkolan.com/Extranet/Extranet/wf_login.aspx and select a pricing tier at https://www.inkolan.com/tarifas/.","Select the target work polygon/hectare to download layered ETRS89 DWG CAD files with operator-specific symbology legends."],"reading_traps":["Not a free or bulk open-data download; priced per project area/hectare or annual subscription.","Covers participating partner utilities (Iberdrola/i-DE, Endesa/e-distribución, UFD, Viesgo, E-REDES) and not all ~325 local Spanish DSOs."]},"test":{"tested_on":"2026-11-16","method":"page_only","http_status":200,"content_type":"text/html","size_bytes":null,"records_total":null,"records_for_country":null,"problems":["Paid commercial service requiring registration and area-based fees."]},"evidence":[{"claim":"Consortium providing digital electricity, gas, telecom and water network files from major operators","url":"https://www.inkolan.com/somos-inkolan/","quote":"Agrupación constituida por la mayor parte de los grandes operadores de servicios públicos ... facilitamos el suministro de información digital de infraestructuras de agua, gas, electricidad, telecomunicaciones y redes municipales"},{"claim":"Pricing example and national subscription fee","url":"https://www.inkolan.com/tarifas/","quote":"Ejemplo para una descarga de una superficie de 1 ha.: 45,23€"}],"members":[],"members_summary":null}],"sector":{"regulator":{"name":"Comisión Nacional de los Mercados y la Competencia (CNMC)","url":"https://www.cnmc.es/sectores-que-regulamos/energia/supervision-del-mercado-electrico/informe-acceso-y-conexion-redes"},"operators":{"structure":"many","note":"Under Ley 24/2013 Art. 34.2, Red Eléctrica de España, S.A.U. (REE / Redeia) acts as sole statutory transmission operator (TSO) in exclusivity (with limited ministry-authorized DSO exceptions in secondary transmission). Distribution (<220 kV) is fragmented across 325 active operators in CNMC's census (366 rows incl. 41 Baja) and 326 in MITECO's GECOS Registry, led by 5 major groups (i-DE/Iberdrola, e-distribución/Endesa, UFD/Naturgy, Viesgo, E-REDES/EDP) plus ~300 small local distributors (grouped in CIDE and ASEME).","census_url":"https://sede.cnmc.gob.es/listado/censo/1"},"publication_obligation":{"exists":"no_evidence_found","norm":"Ley 24/2013 del Sector Eléctrico (Art. 33.9, 34, 38-40); CNMC Circular informativa 6/2025 (BOE-A-2025-20259); Real Decreto 1955/2000","url":"https://www.boe.es/diario_boe/txt.php?id=BOE-A-2025-20259","what_must_be_published":"No statutory obligation found requiring operators to publish open GIS line-route geometries. Ley 24/2013 Art. 33.9 and CNMC Circular 6/2025 mandate monthly reporting and publication of substation UTM coordinates and node access capacity only; RD 1955/2000 publishes individual line authorizations in official gazettes.","frequency":"Monthly for substation capacity maps; no schedule for line routes"},"consolidated_republication":{"found":"no_evidence_found","note":"No public regulator or ministry republishes consolidated operator line-route GIS. IGN independently captures visible overhead power lines topographically in BTN (from PNOA/photogrammetry and regional BTA), while Inkolan is a commercial B2B consortium serving DWG plans for a fee.","checked_pages":[{"organization":"CNMC","url":"https://www.cnmc.es/sectores-que-regulamos/energia/supervision-del-mercado-electrico/informe-acceso-y-conexion-redes","saw":"Publishes monthly ArcGIS Experience demand and generation capacity maps showing substation point layers only (esriGeometryPoint), no line geometries."},{"organization":"MITECO","url":"https://www.miteco.gob.es/es/cartografia-y-sig/ide/descargas.html","saw":"IDE download directory lists water, biodiversity, environmental quality, climate, coasts, demographic challenge and AEMET stations; no electricity grid layer."},{"organization":"MITECO (GECOS)","url":"https://energia.serviciosmin.gob.es/Gecos/DatosPublicos/ConsultaRegistro","saw":"Public registry of 326 electricity distribution companies (name, address, municipality, province, registration ID); no network geometry."},{"organization":"Red Eléctrica de España (REE)","url":"https://www.ree.es/es/transporte-electricidad/red-transporte/nuestras-infraestructuras","saw":"Directs external users seeking line locations to Infored request portal ('Portal para las solicitudes de información sobre las líneas propiedad de la compañía')."},{"organization":"IGN / IDEE","url":"https://api-features.idee.es/collections?f=json","saw":"OGC API Features serves 38 INSPIRE collections (AD, ELU, LC, HY, TN including ropeway cablewaylink) with no Utility Services / electricity network collection."}]}},"national_registry":{"exists":"partial","note":"No single public official registry covers both transmission and distribution routes with voltage, operator and status. IGN's Base Topográfica Nacional (BTN 0710L_LIN_ELEC) provides official national overhead geometries and banded voltage (excluding underground/submarine cables, operator and status); REE maintains internal GeoRED transmission GIS accessible externally via individual Infored requests; distribution networks are held separately by 325 active DSOs.","checked_pages":[{"organization":"CNMC","url":"https://www.cnmc.es/sectores-que-regulamos/energia/supervision-del-mercado-electrico/informe-acceso-y-conexion-redes","saw":"Monthly ArcGIS capacity maps under Circular 6/2025 contain substation points (Demanda_en_Transporte_v2, Demanda_en_Distribucion, Generacion_en_Transporte, Generacion_en_Distribucion) with no line routes."},{"organization":"MITECO","url":"https://www.miteco.gob.es/es/energia/infraestructuras-integracion/infraestructuras.html","saw":"Describes binding national transmission planning under Ley 24/2013 Art. 4; annexes publish schematic PDF maps (e.g. 2025-2030 Annex III), not GIS vector datasets."},{"organization":"Red Eléctrica de España (REE)","url":"https://www.ree.es/es/transporte-electricidad/red","saw":"States Spain's transmission grid has >46,000 km of circuits (400/220 kV mainland; 220/132/66 kV islands) and links to Infored request portal; public GeoRED exposes only 63 sample circuits."},{"organization":"Instituto Geográfico Nacional (IGN)","url":"https://www.ign.es/resources/docs/IGNCnig/BTN/ESPBTN.pdf","saw":"Technical specification for BTN 0710L_LIN_ELEC (overhead lines nationwide in BTN_T_Energia GeoPackage and vt-btn.idee.es MVT tiles; excludes underground lines, operator and status)."}]},"if_unstructured":{"summary":null,"recipe":["1. Search BOE (https://www.boe.es/buscar/) or regional official gazettes (for intra-regional <220 kV distribution lines) using terms 'autorización administrativa', 'línea eléctrica', and 'utilidad pública' to collect authorization resolutions and determine operational/construction status.","2. From each resolution (HTML text at https://www.boe.es/diario_boe/txt.php?id=<BOE-ID>), parse the 'Primero' technical block to extract operator, Tensión nominal (kV), Longitud (km), N.º de circuitos, and origin/destination substations or support numbers.","3. When Declaración de Utilidad Pública (DUP) is included (e.g. BOE-A-2026-19932 Anexo II), extract the tabular list of affected cadastral parcels (Polígono, Parcela, Referencia catastral, Término municipal).","4. For new projects in environmental review without a BOE DUP table yet, query MITECO SABIA (navServicioContenido) by title/region to retrieve project code, procedural status, and consultation documents."],"location_method":"Extract the ordered sequence of affected 14/20-character cadastral parcel references (Referencia catastral, e.g. '49146A00100008') from Anexo II of BOE/regional DUP notices, resolve parcel geometries via Sede Electrónica del Catastro (https://www.sedecatastro.gob.es/OVCInicio.aspx), and verify pylon bases and overhead spans visually over IGN PNOA Máxima Actualidad WMTS orthophotos (https://www.ign.es/wmts/pnoa-ma?REQUEST=GetCapabilities&SERVICE=WMTS).","cross_with":["IGN BTN 0710L_LIN_ELEC (https://vt-btn.idee.es/1.0.0/btn/tile/{z}/{y}/{x}.pbf) and 0716P_TOR_ALT_TEN (pylons) to match existing overhead route geometries to operators/voltages extracted from BOE/SABIA.","CNMC Circular 6/2025 substation feature layers (https://www.cnmc.es/sectores-que-regulamos/energia/supervision-del-mercado-electrico/informe-acceso-y-conexion-redes) to verify substation names, UTM coordinates and GESTOR_RED (DSO/TSO) endpoints.","MITECO GECOS Distributor Registry (https://energia.serviciosmin.gob.es/Gecos/DatosPublicos/ConsultaRegistro) and CNMC census (https://sede.cnmc.gob.es/listado/censo/1) to normalize DSO legal names and R1-xxx registration codes."],"where_published":[{"name":"Boletín Oficial del Estado (BOE) — Energy Authorizations & DUP Resolutions","url":"https://www.boe.es/buscar/","what":"Official authorizations (Autorización Administrativa Previa, de Construcción, and Declaración de Utilidad Pública) for transmission lines (>132/220/400 kV or interregional) and large generation evacuation lines, detailing operator, voltage, length, circuit count, start/end supports/substations, status, and Anexo II cadastral parcel tables.","how_to_search_inside":"Open https://www.boe.es/buscar/ ('Todo el BOE' or 'Otras Disposiciones'), search quoted phrases such as '\"autorización administrativa de construcción\" \"línea aérea\" \"kV\"' plus company or province name; note results require manual or script filtering across notices.","example_document":{"url":"https://www.boe.es/diario_boe/txt.php?id=BOE-A-2026-19932","what_it_gives":"BOE-A-2026-19932 (2026-09-03): Operator 'Red Eléctrica de España, SAU'; Voltage 'Tensión nominal: 400 kV' / 'Tensión más elevada de la red: 420 kV'; Length & circuits 'Longitud: 0,190 km', 'N.º de circuitos: 2'; Status 'autorización administrativa previa' + 'autorización administrativa de construcción' + 'declarar, en concreto, la utilidad pública'; Endpoints 'Origen de la línea: apoyo 205N de la L/400kV Grijota-Villarino 2' to 'futura SE Moreruela 400 kV'; ANEXO II parcel table '1 | 1 | 8 | 49146A00100008 | Moreruela de los Infanzones (Zamora)'."}},{"name":"MITECO SABIA — Consulta pública de evaluaciones ambientales","url":"https://sede.miteco.gob.es/portal/site/seMITECO/navServicioContenido","what":"National Environmental Impact Assessment (EIA) project database publishing active and historical files for overhead/underground power lines and generation evacuation lines, including project code, promoter/operator, Autonomous Community, and procedural status.","how_to_search_inside":"Filter by Comunidad Autónoma (dropdown or map), project type ('select_tipo'), promoter ('select_promotor'), procedural stage ('select_estado_tramitacion'), project code ('codigo') or free-text title ('titulo'); public consultation highlights are also listed directly at https://sede.miteco.gob.es/portal/site/seMITECO/navSabiaDestacados.","example_document":{"url":"https://sede.miteco.gob.es/portal/site/seMITECO/navSabiaDestacados","what_it_gives":"Highlighted public consultation list showing e.g. code '20260258': 'PRÓRROGA DE LA DIA DEL PROYECTO PLANTAS FOTOVOLTAICAS QUILLA SOLAR, DE 74 MWP, PORTALÓN SOLAR, DE 74 MWP Y SPINNAKER SOLAR, DE 50,50 MWP, ASÍ COMO SUS INFRAESTRUCTURAS DE EVACUACIÓN ASOCIADAS, EN LA PROVINCIA DE MADRID', 'Fecha de fin de consultas 2026-12-28'."}}]},"related_not_answering":[{"name":"CNMC Electricity Access Capacity Maps (Demand & Generation)","url":"https://www.cnmc.es/sectores-que-regulamos/energia/supervision-del-mercado-electrico/informe-acceso-y-conexion-redes","why":"ArcGIS Experience apps and underlying FeatureServers publish substation node points (esriGeometryPoint) and MW capacity only, with no power line route geometries."},{"name":"REE Mapa de Proyectos de la Red de Transporte","url":"https://www.ree.es/es/transporte-electricidad/proyectos-transporte/mapa-proyectos","why":"Covers under-development transmission projects only (77 lines in embedded JSON as of Sept 2024), and every line geometry is a 2-point straight segment between substations rather than a physical route."},{"name":"REE GeoRED Public Service (Zonas_de_detalle_WEBREE_MIL1)","url":"https://georedservices.ree.es/arcgis_ags2/rest/services/Zonas_de_detalle_WEBREE_MIL1/MapServer","why":"Exposes only 63 overhead circuits and 18 underground cables across isolated sample detail zones, not national transmission coverage."},{"name":"IDEE WFS INSPIRE Transport Networks (IGR_Transporte)","url":"https://www.idee.es/csw-codsi-idee/srv/api/records/spaignwfs_IGR_Transporte?language=eng","why":"Covers road, rail, water, air, and ropeway ('transporte por cable' / cablewaylink) modes only; contains no electricity transmission or distribution lines."},{"name":"Zenodo Data of the Spanish Electric Power System (iDesignRES)","url":"https://zenodo.org/api/records/14748878","why":"Provides bus coordinates (bus_data.csv) and topological edge table (line_data.csv, >=220 kV) derived from OSM/ENTSO-E without line route geometry."},{"name":"DSO Capacity & Outage Map Portals (e-distribución, UFD, Viesgo, E-REDES)","url":"https://www.edistribucion.com/es/red-electrica/nodos-capacidad-red/capacidad-generacion.html","why":"Publish substation capacity points or outage/works viewers rather than distribution line route geometries (also checked ufd.es, viesgodistribucion.com, eredesdistribucion.es; i-de.es returned 503)."},{"name":"Regional Avifauna Protection Zone Polygons (Navarra, Castilla y León, Aragón, Cantabria)","url":"https://idena.navarra.es/descargas/BIODIV_Pol_ImpElecAvi.zip","why":"Contain polygon protection/sensitivity zones under RD 1432/2008 (Navarra BIODIV_Pol_ImpElecAvi, CyL avifau_cyl_prot_laat, Aragón, Cantabria layer 60), not power line route geometries."},{"name":"World Bank energydata.info — Spain Electricity Transmission Network 2017","url":"https://energydata.info/api/3/action/package_show?id=spain-electricity-transmission-network-2017","why":"Covers only the 2016 Spain-Morocco international interconnection (sourced from Arab Union of Electricity / ONE Morocco), not Spain's domestic grid."}],"open_questions":["Does CNIG's BTN_T_Energia.gpkg downloadable via interactive browser at https://centrodedescargas.cnig.es/CentroDescargas/btn expose any additional fields on 0710L_LIN_ELEC beyond id, tensi_0710 and f_alta served in vt-btn.idee.es MVT tiles (ESPBTN.pdf lists NOMBRE, ETIQUETA, ID_BIC, ID_BICCA as optional/common attributes, not operator or status)?","Are non-public regional electric network datasets marked 'Acceso: Parcialmente público' (such as Catalonia PCC red-lineas-electricas) accessible via formal inter-administrative agreement?"],"history":[{"pass":1,"date":"2026-11-16","role":"research","model":"Gemini 4 Hydrogen (Extra High)","rules_version":"6.12","note":"Initial research pass: mapped national BTN MVT API, regional WFS (Andalucia MIEA, La Rioja BTA), REE Infored, ENTSO-E, MITECO PDFs, OSM/OpenInfraMap, and Inkolan.","headline":{"official_data":"partial","non_official_data":"partial","national_registry":"partial"},"sources":{"total":8,"new":8,"dropped":0},"negatives":{"overturned":0,"confirmed":0},"effort":{"pages":141,"minutes":28}}],"local_terms":[{"term":"red de transporte (primario / secundario)","language":"es","meaning":"Electricity transmission grid (>=380/400 kV primary, >=220 kV secondary mainland, >=66 kV non-peninsular)"},{"term":"red de distribución","language":"es","meaning":"Electricity distribution network (<220 kV mainland except secondary transmission; HV 132/66/50/45 kV, MV, LV)"},{"term":"línea eléctrica / tendido eléctrico","language":"es","meaning":"Power line / overhead electrical line (BTN 0710L_LIN_ELEC; BTA f_0116_tendido_lineas)"},{"term":"tensión (kV)","language":"es","meaning":"Voltage level in kilovolts"},{"term":"transportista único","language":"es","meaning":"Sole statutory transmission system operator (Red Eléctrica de España, S.A.U.)"},{"term":"empresa distribuidora","language":"es","meaning":"Distribution system operator (DSO)"},{"term":"autorización administrativa previa / de construcción","language":"es","meaning":"Official prior and construction administrative authorizations published in BOE/regional gazettes"},{"term":"declaración de utilidad pública (DUP)","language":"es","meaning":"Public utility declaration publishing affected cadastral polygons and parcels (Anexo II)"}],"provenance":{"pass_count":1,"models":["Gemini 4 Hydrogen (Extra High)"],"minutes_estimate":28,"pages_opened":141,"passes":[{"pass":1,"date":"2026-11-16","model":"Gemini 4 Hydrogen (Extra High)"}],"note":"Minutes are researcher estimates. Counts describe documented passes, not publication approval. Missing history or effort is not reconstructed."},"card_url":"https://georutter.org/v1/es/power-lines.json","detail_url":"https://georutter.org/v1/es/power-lines/detail.json","html_url":"https://georutter.org/es/power-lines/","country_url":"https://georutter.org/v1/countries/es.json"}