{"schema_version":"1.0","country":"us","country_name":"United States","topic":"hydropower-plants","question":"Where can I get a list of hydropower plants and dams in the United States, with location, capacity (MW), reservoir volume, operator and annual generation?","territory":"us","territory_level":"country","parent_url":null,"published_on":"2026-11-20","research_reviewed_on":"2026-11-20","access_checked_on":"2026-11-20","answer":{"official_data":"structured","non_official_data":"not_tested","summary":"No single official table links hydro plants and dams. EIA-860 (2025) lists 1,457 hydro plants (3,981 conventional and 150 pumped-storage generators) with coordinates, MW and operator; EIA-923 adds 2025 net MWh, negative at many pumped-storage plants. USACE's National Inventory of Dams (CSV updated 2026-11-20; 92,674 rows, 2,529 with a hydroelectric purpose) gives dam location, owner and normal/maximum storage in acre-feet but no MW or EIA code. A coordinate join matched 967 of 1,457 EIA plants within 1 km of an NID hydro dam. ORNL's EHA database sits behind a form.","main_caveats":["No common key between EIA plant codes and NID IDs; the coordinate join matched 967 of 1,457 EIA plants within 1 km and is not a published crosswalk.","Counting units differ: EIA = generators/plants (a dam may be two plants, e.g. Hoover NV+AZ); NID = dams and associated structures (Bath County has five rows).","NID gives owners, normal and maximum storage (acre-feet), but no MW, operator or EIA/FERC IDs; hydroelectric purpose is incomplete (Grand Coulee lacks it).","EIA-923 net generation at pumped-storage plants is often negative (22 of 39 plants with pumped-storage generators); do not read it as production.","NID storage definitions (normal includes dead storage; max includes surcharge) were found only on mirrored dictionaries, not USACE's own.","ORNL's EHA plant database was not downloaded: its page requires a Data Use Policy form with personal details."],"confidence":"medium","confidence_reason":"EIA-860/923 and NID were downloaded and cross-checked on four facilities and by a measured spatial join; EHA was not opened and NID definitions rest on mirrors.","attributes":[{"attribute":"location","covered":"partial","source_ids":["eia-860-hydro","nid-usace"],"note":"EIA-860 plant points and NID dam points exist; no published key links a plant to its dams (967 of 1,457 plants have an NID hydro dam within 1 km).","gap":"not_published","gap_note":"NID and EIA carry no shared identifier; ORNL EHA, which may bridge them, was not downloaded (data-use form). One dam can be several EIA plants (Hoover) and one plant several NID structures (Bath County)."},{"attribute":"capacity_mw","covered":"partial","source_ids":["eia-860-hydro"],"note":"EIA-860 nameplate/net MW per generator for hydro plants of 1 MW or more (conventional 80,061 MW, pumped storage 22,224 MW nameplate).","gap":"not_published","gap_note":"Plants under 1 MW are not in EIA-860 and NID has no MW column, so NID hydro-purpose dams without an EIA plant nearby (852 of 2,528 are more than 5 km from any EIA hydro plant) have no capacity."},{"attribute":"reservoir_volume","covered":"yes","source_ids":["nid-usace"],"note":"NID Normal, Max and NID Storage in acre-feet and surface area; zero or blank for dams without storage (2,386 of 2,529 hydro rows have normal storage).","gap":null,"gap_note":null},{"attribute":"operator","covered":"partial","source_ids":["eia-860-hydro","eia-923-hydro","nid-usace"],"note":"EIA-860/923 give the operating company per plant; NID gives owners, not operators (179 of 2,528 hydro rows have no owner).","gap":"not_published","gap_note":"No operator field for dams; owner/operator differences between associated NID structures and the EIA plant are not published (Conowingo: NID owner blank, EIA operator Constellation Power, Inc)."},{"attribute":"annual_generation","covered":"yes","source_ids":["eia-923-hydro"],"note":"EIA-923 2025 net generation (MWh) by plant, 1,401 hydro plants; negative totals at many pumped-storage plants; dams without generators have none.","gap":null,"gap_note":null}]},"sources":[{"source_id":"eia-860-hydro","name":"Annual Electric Generator Report, Form EIA-860 (hydroelectric generators, 2025)","publisher":"U.S. Energy Information Administration (EIA)","official":true,"landing_url":"https://www.eia.gov/electricity/data/eia860/","data_url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","access":"direct_download","format":"Zip of Excel (.xlsx) workbooks (Plant, Generator Operable/Proposed/Retired, Owner, Layout)","license":"Unknown","language":"English","has_coordinates":true,"location_precision":"exact","adds":"Plant coordinates, generator capacity (MW), technology (conventional vs pumped storage) and operator for hydro plants of 1 MW or more.","first_seen_pass":1,"rank":1,"summary":"EIA-860 lists 4,131 hydro generators at 1,457 plants (80,061 MW conventional, 22,224 MW pumped storage nameplate) with plant coordinates and operator.","coverage_note":"Plants of 1 MW or more; final 2025 data; no dam or reservoir fields.","data_date":"2025","caveats":["A dam can be split into several plants (Hoover Dam NV and AZ).","No key to the National Inventory of Dams."],"coverage":{"geographic":"United States; plants of 1 MW or more combined nameplate capacity."},"fine_print":{"unit":{"value":"Generator within a plant (Plant Code); hydro = Technology 'Conventional Hydroelectric' or 'Hydroelectric Pumped Storage'.","quote":"3_1_GeneratorYyyyy — Contains generator-level data for the surveyed generators, split into three tabs.","url":"https://www.eia.gov/electricity/data/eia860/","attempts":[]},"inclusion_rule":{"value":"Plants with 1 MW or greater combined nameplate capacity.","quote":"The survey Form EIA-860 collects generator-level specific information about existing and planned generators and associated environmental equipment at electric power plants with 1 megawatt or greater of combined nameplate capacity.","url":"https://www.eia.gov/electricity/data/eia860/","attempts":[]},"reference_date":{"value":"2025 final data, released September 10, 2026.","quote":"Release Date: September 10, 2026, Final 2025 data","url":"https://www.eia.gov/electricity/data/eia860/","attempts":[]},"update_frequency":{"value":"Annual final release in September.","quote":"Next Monthly Release: June 2027, Early release 2026 data","url":"https://www.eia.gov/electricity/data/eia860/","attempts":[]},"exclusions":{"value":"Hydro plants under 1 MW and any dam without generators are not included; no reservoir fields.","quote":null,"url":null,"attempts":[{"url":"https://www.eia.gov/electricity/data/eia860/","note":"Plant and Generator sheets of the 2025 workbook contain no reservoir volume or dam identifier."}]}},"key_fields":[{"field":"Plant Code / Plant Name / State / County","meaning":"Plant identifier shared with EIA-923; name and place."},{"field":"Latitude / Longitude","meaning":"Plant point coordinates."},{"field":"Utility ID / Utility Name","meaning":"Company responsible for the day-to-day operation (operator)."},{"field":"Technology / Prime Mover","meaning":"Conventional Hydroelectric (HY) or Hydroelectric Pumped Storage (PS)."},{"field":"Nameplate Capacity (MW) / Summer Capacity (MW) / Winter Capacity (MW)","meaning":"Generator capacity bases."},{"field":"Status / Operating Year","meaning":"OP, SB, OA, OS and commissioning year."}],"how_to_use":{"example_request":"curl -L -o eia8602025.zip https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip && unzip eia8602025.zip -d eia860_2025  # filter 3_1_Generator_Y2025.xlsx (Operable) on Technology in ('Conventional Hydroelectric','Hydroelectric Pumped Storage'); join 2___Plant_Y2025.xlsx on Plant Code","example_result":"4,131 hydro generators at 1,457 plants: 3,981 conventional (80,061 MW nameplate) and 150 pumped-storage at 39 plants (22,224 MW). Plant 1574 Conowingo, Constellation Power, Inc, Harford MD, 39.6572 / -76.1752, 11 generators 530.8 MW.","steps":["Download and open the Operable sheet; filter hydro technologies.","Join the Plant sheet for coordinates and state.","Join EIA-923 for annual generation on Plant Code."],"reading_traps":["A dam can be reported as several plants: Hoover Dam appears as plant 154 (NV, 9 generators) and plant 8902 (AZ, 10 generators), each 1,039.4 MW nameplate.","Pumped-storage generators also occur at plants labelled conventional (Grand Coulee has PS prime-mover rows).","No dam ID or reservoir data: link to the National Inventory of Dams yourself."]},"test":{"tested_on":"2026-11-20","method":"download","http_status":200,"content_type":"application/x-zip-compressed","size_bytes":23622347,"records_total":27919,"records_for_country":4131,"problems":["records_total is all Operable generators; records_for_country is hydro generators (1,457 plants). Planned (Proposed tab) hydro not counted."]},"evidence":[{"claim":"Operator definition.","url":"https://www.eia.gov/electricity/data/eia860/","quote":"EIA-assigned identification number for the company that is responsible for the day-to-day operations of the generator"},{"claim":"Measured hydro generators in the Operable tab.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"Technology Conventional Hydroelectric 3,981 generators; Hydroelectric Pumped Storage 150; 1,457 distinct Plant Codes"}],"members":[],"members_summary":null},{"source_id":"eia-923-hydro","name":"Form EIA-923 detailed data, 2025 final (hydro rows)","publisher":"U.S. Energy Information Administration (EIA)","official":true,"landing_url":"https://www.eia.gov/electricity/data/eia923/","data_url":"https://www.eia.gov/electricity/data/eia923/xls/f923_2025.zip","access":"direct_download","format":"Zip of Excel (.xlsx) workbooks","license":"Unknown","language":"English","has_coordinates":false,"location_precision":"none","adds":"Annual net generation (MWh) of hydro plants by plant and prime mover (HY, PS).","first_seen_pass":1,"rank":2,"summary":"EIA-923 gives 2025 net generation in MWh for 1,401 hydro plants joinable to EIA-860 on plant code; pumped-storage plants can show negative totals.","coverage_note":"Final 2025 data; plant level, no dam identifier.","data_date":"2025","caveats":["Negative net generation at pumped-storage plants.","Plants spanning two states are reported as separate plants."],"coverage":{"geographic":"United States"},"fine_print":{"unit":{"value":"Page 1 row = plant x prime mover x fuel (hydro fuel code WAT).","quote":"EIA-923 Monthly Generation and Fuel Consumption Time Series File,  2025 Final Data","url":"https://www.eia.gov/electricity/data/eia923/xls/f923_2025.zip","attempts":[]},"inclusion_rule":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://www.eia.gov/electricity/data/eia923/","note":"Respondent threshold not stated on the page text opened."}]},"reference_date":{"value":"Calendar 2025 final data, released September 14, 2026.","quote":"Annual release date: September 14, 2026; Final release 2025 data","url":"https://www.eia.gov/electricity/data/eia923/","attempts":[]},"update_frequency":{"value":"Monthly plus annual final.","quote":"monthly release: End of November 2026 (September 2026 data) Annual release date: September 14, 2026; Final release 2025 data Next annual release: September 2027 for 2026 final data","url":"https://www.eia.gov/electricity/data/eia923/","attempts":[]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://www.eia.gov/electricity/data/eia923/","note":"1,401 of 1,457 EIA-860 hydro plants have WAT rows in Page 1; the other 56 were not examined."}]}},"key_fields":[{"field":"Plant Id / Plant Name / Operator Name","meaning":"Plant code (same as EIA-860 Plant Code) and operator."},{"field":"Reported Prime Mover / Reported Fuel Type Code","meaning":"HY or PS; fuel WAT."},{"field":"Net Generation (Megawatthours)","meaning":"Annual net generation; monthly Netgen columns."}],"how_to_use":{"example_request":"curl -L -o f923_2025.zip https://www.eia.gov/electricity/data/eia923/xls/f923_2025.zip && unzip f923_2025.zip  # EIA923_Schedules_2_3_4_5_M_12_2025_Final.xlsx, sheet 'Page 1 Generation and Fuel Data', header row 6, Reported Fuel Type Code = WAT","example_result":"Plant Id 1574 Conowingo (HY, WAT): 1,548,934 MWh in 2025; Hoover Dam NV 154: 1,807,912 MWh; Hoover Dam AZ 8902: 927,107 MWh; Bath County 6167 (PS): -1,083,343 MWh.","steps":["Filter Reported Fuel Type Code = WAT.","Sum Net Generation (Megawatthours) by Plant Id.","Treat pumped-storage plants separately (negative values)."],"reading_traps":["Pumped-storage net generation can be negative: 22 of the 39 plants with pumped-storage generators have negative annual WAT net generation.","Net generation only; plants split across states (Hoover) must be summed by hand."]},"test":{"tested_on":"2026-11-20","method":"download","http_status":200,"content_type":"application/x-zip-compressed","size_bytes":23340452,"records_total":18889,"records_for_country":1401,"problems":["records_total is Page 1 rows; records_for_country is the hydro plants with WAT rows (235,663,595 MWh in total including pumping losses)."]},"evidence":[{"claim":"Measured: hydro plants present and negative pumped-storage totals.","url":"https://www.eia.gov/electricity/data/eia923/xls/f923_2025.zip","quote":"Fuel WAT rows at EIA-860 hydro plants: 1,401 plants, 235,663,595 MWh; Bath County (6167) PS: -1083343"}],"members":[],"members_summary":null},{"source_id":"nid-usace","name":"National Inventory of Dams (NID)","publisher":"U.S. Army Corps of Engineers (USACE), with state and federal dam-safety agencies","official":true,"landing_url":"https://nid.sec.usace.army.mil/","data_url":"https://nid.sec.usace.army.mil/api/nation/csv","access":"direct_download","format":"CSV (85 columns; first line is a 'Data Last Updated' row); other formats on the site","license":"Unknown","language":"English","has_coordinates":true,"location_precision":"exact","adds":"Dam and reservoir records with coordinates, owners, purposes (including hydroelectric), normal and maximum storage in acre-feet; no MW and no EIA code.","first_seen_pass":1,"rank":3,"summary":"USACE's National Inventory of Dams CSV (92,674 rows, updated 2026-11-20) gives dam coordinates, owners, purposes and normal/maximum reservoir storage in acre-feet; 2,529 rows list hydroelectric as a purpose.","coverage_note":"All dams including associated structures; no MW, operator or EIA plant code.","data_date":"2026-11-20","caveats":["Owners are not operators; 179 hydro rows have no owner.","Hydroelectric purpose is incomplete (Grand Coulee Dam lacks it)."],"coverage":{"geographic":"United States and territories (92,674 rows including 1,008 associated structures)."},"fine_print":{"unit":{"value":"One row per dam or associated structure (NID ID; 'Is Associated Structure?' flag, 'Number of Associated Structures').","quote":null,"url":null,"attempts":[{"url":"https://nid.sec.usace.army.mil/api/nation/csv","note":"Counting unit read from the CSV columns; USACE data dictionary not opened."}]},"inclusion_rule":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://nid.sec.usace.army.mil/","note":"Home page lists the inventory; inclusion thresholds not read. Search results describe the NID's size/storage criteria only through mirrors."}]},"reference_date":{"value":"First CSV line 'Data Last Updated:,2026-11-20' on the download day.","quote":"Data Last Updated:,2026-11-20","url":"https://nid.sec.usace.army.mil/api/nation/csv","attempts":[]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://nid.sec.usace.army.mil/","note":"No schedule seen; the CSV date equalled the download date."}]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://nid.sec.usace.army.mil/api/nation/csv","note":"Purposes contains 'Hydroelectric' for 2,529 rows; Grand Coulee Dam (WA00262) does not list it despite a 6,809 MW EIA plant."}]}},"key_fields":[{"field":"NID ID / Dam Name / Other Names / Is Associated Structure?","meaning":"Dam identifier, names and flag for associated structures."},{"field":"Latitude / Longitude / State / County / River or Stream Name","meaning":"Dam point and location."},{"field":"Owner Names / Primary Owner Type / Federal Agency Owners","meaning":"Owners (not operators); blank for 179 hydro rows with coordinates."},{"field":"Primary Purpose / Purposes","meaning":"Purposes; 'Hydroelectric' appears in Purposes of 2,529 rows and as primary purpose of 2,113."},{"field":"Normal Storage (Acre-Ft) / Max Storage (Acre-Ft) / NID Storage (Acre-Ft) / Surface Area (Acres)","meaning":"Normal storage, maximum storage, derived NID storage (larger of the two per mirrors) and surface area."},{"field":"Federal Agency Involvement Regulatory","meaning":"Federal regulator involvement (e.g. FERC on 1,744 hydro-purpose rows)."},{"field":"Operational Status / Condition Assessment / Hazard Potential Classification","meaning":"Dam safety status fields."}],"how_to_use":{"example_request":"curl -L -A 'client/1.0' -o nid_all.csv https://nid.sec.usace.army.mil/api/nation/csv  # skip line 1 ('Data Last Updated'), filter Purposes containing 'Hydroelectric'","example_result":"92,674 rows, 69,877,384 bytes. NID ID MD00097 'Conowingo' (39.6609, -76.1733): Hydroelectric;Recreation;Water Supply, Normal Storage 301,400 acre-ft, Max Storage 310,000, Owner Names blank. NID ID NV10122 'Hoover Dam': normal storage 28,255,000 acre-ft.","steps":["Download the nation CSV; skip the first metadata line.","Filter Purposes containing 'Hydroelectric'.","Match to EIA plants by coordinates (see reading traps) or name and state."],"reading_traps":["No MW, no operator, no EIA plant code or FERC project number in the 85 columns: EIA and NID must be linked by coordinates or name.","Spatial join measured on 2026-11-20: 967 of 1,457 EIA hydro plants have an NID hydro-purpose structure within 1 km (1,063 within 2 km, 1,172 within 5 km); 1,139 of 2,528 NID hydro-purpose structures lie within 1 km of an EIA hydro plant.","One facility can be many NID rows (Bath County: Upper Reservoir VA017006, Lower Reservoir VA017007, fuse plug, two recreation ponds) and one NID dam can be several EIA plants (Hoover Dam).","Hydro dams missing the purpose: Grand Coulee Dam WA00262 lists 'Flood Risk Reduction;Irrigation' only.","Storage definitions (normal includes dead storage, max includes surcharge) come from mirrored data dictionaries, not USACE."]},"test":{"tested_on":"2026-11-20","method":"download","http_status":200,"content_type":"application/octet-stream","size_bytes":69877384,"records_total":92674,"records_for_country":2529,"problems":["records_for_country is rows whose Purposes include Hydroelectric (2,528 have coordinates); normal storage > 0 for 2,386 of the 2,529.","USACE data dictionary and API documentation were not located; /api/dictionary returned 404."]},"evidence":[{"claim":"Dataset date on download.","url":"https://nid.sec.usace.army.mil/api/nation/csv","quote":"Data Last Updated:,2026-11-20"},{"claim":"Hydro rows, storage and regulator involvement measured in the CSV.","url":"https://nid.sec.usace.army.mil/api/nation/csv","quote":"92,674 rows; Purposes includes Hydroelectric: 2,529; Normal Storage > 0: 2,386; Federal Agency Involvement Regulatory = Federal Energy Regulatory Commission: 1,744"}],"members":[],"members_summary":null},{"source_id":"ornl-eha-plant","name":"Existing Hydropower Assets (EHA) Plant Database, 2026 (and EHA Unit Database)","publisher":"Oak Ridge National Laboratory (HydroSource, U.S. DOE)","official":true,"landing_url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","data_url":null,"access":"registration_required","format":"XLSX (560 KB) and CSV (652 KB) per the page","license":"Unknown","language":"English","has_coordinates":null,"location_precision":null,"adds":"Curated hydro plant inventory that, per its description, joins location, ownership, FERC status, installed capacity and annual generation; probably the intended bridge between EIA and dam data.","first_seen_pass":1,"rank":4,"summary":"ORNL's curated hydro plant database (2026) lists capacity and generation with FERC and ownership attributes, but its download sits behind a data-use form.","coverage_note":"Page read only; file contents not verified; revision dated 2026-07-16.","data_date":"2026-07-16","caveats":["Download needs a Data Use Policy form with personal details; not tested.","Whether it carries NID, EIA or FERC IDs is unverified."],"coverage":{"geographic":"United States hydroelectric and pumped-storage plants (per page)."},"fine_print":{"unit":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","note":"File not downloaded; description lists plant-level records, unit database separate."}]},"inclusion_rule":{"value":null,"quote":null,"url":null,"attempts":[]},"reference_date":{"value":"Dataset revision of July 16, 2026 'Includes EIA 923 generation revision data for MWh and Pf columns'.","quote":"Includes EIA 923 generation revision data for MWh and Pf columns","url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","attempts":[]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","note":"Annual editions (2026 shown); no schedule stated."}]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[]}},"key_fields":[],"how_to_use":{"example_request":"","example_result":"","steps":["Open the page; downloads require a Data Use Policy form asking name, email, company and use."],"reading_traps":["Not downloaded: column names, identifiers (NID, EIA, FERC) and counts are unverified."]},"test":{"tested_on":"2026-11-20","method":"page_only","http_status":200,"content_type":"text/html","size_bytes":191554,"records_total":null,"records_for_country":null,"problems":["The page gates downloads behind a Data Use Policy form requiring personal details; no form was submitted and the file URLs embedded in the page were not requested."]},"evidence":[{"claim":"Scope stated on the page.","url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","quote":"Existing Hydropower Assets (EHA) Plant Database provides a comprehensive nationwide inventory"}],"members":[],"members_summary":null}],"sector":{"regulator":{"name":"U.S. Army Corps of Engineers (NID); Federal Energy Regulatory Commission is shown as regulator on 1,744 NID hydro-purpose rows","url":"https://nid.sec.usace.army.mil/"},"operators":{"structure":"many","note":"Federal agencies (USACE, Bureau of Reclamation, TVA), public utilities and private owners; NID hydro rows by primary owner type: Private 999, Public Utility 626, Federal 327, Local Government 302, Not Listed 164.","census_url":null},"publication_obligation":{"exists":"unknown","norm":null,"url":null,"what_must_be_published":null,"frequency":null},"consolidated_republication":{"found":"partial","note":"EIA consolidates plants and generation; USACE consolidates dams; ORNL HydroSource republishes a curated plant set. No official single table links them.","checked_pages":[{"organization":"U.S. Energy Information Administration","url":"https://www.eia.gov/electricity/data/eia860/","saw":"Final 2025 generator files."},{"organization":"U.S. Army Corps of Engineers","url":"https://nid.sec.usace.army.mil/","saw":"National Inventory of Dams & Low-Head Dams Inventory page; nation CSV."},{"organization":"Oak Ridge National Laboratory","url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","saw":"EHA Plant Database 2026 description and data-use form."}]}},"national_registry":{"exists":"partial","note":"Two national registers exist (EIA plant codes for generating plants of 1 MW or more; USACE NID IDs for dams) but they are not linked by a published key.","checked_pages":[{"organization":"U.S. Energy Information Administration","url":"https://www.eia.gov/electricity/data/eia860/","saw":"Plant and generator files with plant code."},{"organization":"U.S. Army Corps of Engineers","url":"https://nid.sec.usace.army.mil/","saw":"NID home page and CSV with NID ID."},{"organization":"Oak Ridge National Laboratory","url":"https://hydrosource.ornl.gov/data/datasets/eha-plant-2026/","saw":"EHA plant database page (EHA_ID mentioned in revision notes via search; file not opened)."}]},"if_unstructured":{"summary":null,"recipe":[],"where_published":[]},"related_not_answering":[{"name":"EIA-860M monthly generator inventory","url":"https://www.eia.gov/electricity/data/eia860m/","why":"Monthly capacity updates for the same generators; not tested for hydro."},{"name":"HydroSource dataset listing (ORNL)","url":"https://hydrosource.ornl.gov/data/datasets/","why":"Index of other hydropower datasets; only the Plant Database 2026 page was opened."}],"open_questions":[{"question":"Does the ORNL EHA plant/unit database carry NID, EIA plant code and FERC identifiers?","starting_point":"Page opened (description lists plant identification, ownership class, FERC licensing status, installed capacity, annual generation); downloads need a Data Use Policy form.","next_step":"Complete the form in a browser with the project's own details (not done in this run) and inspect the CSV header."},{"question":"What are USACE's official definitions of Normal, Max and NID Storage and the NID inclusion criteria?","starting_point":"Search results pointed to mirrored dictionaries and a DOI (10.21949/1529016) that was not opened.","next_step":"Open the DOI target and compare with the mirrors."},{"question":"Why do 56 of 1,457 EIA hydro plants lack Page 1 WAT rows in EIA-923?","starting_point":"1,401 of 1,457 plants matched in the 2025 final file.","next_step":"List those plants by capacity and status (standby or not reporting)."},{"question":"Are FERC hydropower project records (license IDs) published in a bulk, geocoded form?","starting_point":"NID flags FERC involvement on 1,744 hydro-purpose rows; FERC pages were not opened.","next_step":"Open FERC's hydropower pages and test a download."},{"question":"How should NID hydro-purpose dams without an EIA plant within 5 km be classified (small hydro, retired, mislabelled)?","starting_point":"852 of 2,528 NID hydro-purpose structures are farther than 5 km from any EIA hydro plant (1,676 within 5 km).","next_step":"Sample the unmatched rows and check owners and status."}],"history":[{"pass":1,"date":"2026-11-20","role":"research","model":"claude-sonnet-5-5","rules_version":"2026-11-20-eeuu-electricidad","note":"First pass from scratch: EIA-860/923 and the NID CSV downloaded and joined by coordinates (967 of 1,457 plants within 1 km); ORNL EHA gated by a form and not downloaded.","headline":{"official_data":"structured","non_official_data":"not_tested","national_registry":"partial"},"sources":{"total":4,"new":4,"dropped":0},"negatives":{"overturned":0,"confirmed":0},"effort":{"pages":null,"minutes":null}}],"local_terms":[{"term":"NID ID","language":"en","meaning":"National Inventory of Dams identifier (e.g. MD00097), one per dam or associated structure."},{"term":"Acre-foot (acre-ft)","language":"en","meaning":"Reservoir volume unit used by NID; about 1,233.5 cubic metres."},{"term":"Pumped storage (PS)","language":"en","meaning":"Hydro plant that pumps water uphill; EIA-923 net generation can be negative."}],"provenance":{"pass_count":1,"models":["claude-sonnet-5-5"],"minutes_estimate":null,"pages_opened":null,"passes":[{"pass":1,"date":"2026-11-20","model":"claude-sonnet-5-5"}],"note":"Minutes are researcher estimates. Counts describe documented passes, not publication approval. Missing history or effort is not reconstructed."},"card_url":"https://georutter.org/v1/us/hydropower-plants.json","detail_url":"https://georutter.org/v1/us/hydropower-plants/detail.json","html_url":"https://georutter.org/us/hydropower-plants/","country_url":"https://georutter.org/v1/countries/us.json"}