{"schema_version":"1.0","country":"us","country_name":"United States","topic":"solar-pv-plants","question":"Where can I get a list of solar PV plants in operation in the United States, with location, capacity (MW), operator and commissioning date?","territory":"us","territory_level":"country","parent_url":null,"published_on":"2026-11-19","research_reviewed_on":"2026-11-19","access_checked_on":"2026-11-19","answer":{"official_data":"partial","non_official_data":"partial","summary":"EIA-860 (final 2025) lists 7,979 operating PV generators at 7,309 plants (152,848 MW AC) in 49 states and DC, with plant coordinates, operator (Utility Name) and commercial operation month and year. EIA-860M (September 2026): 8,335 generators, 7,651 plants, 170,562 MW AC, plus Puerto Rico on separate sheets. USGS USPVDB v4.0 (14 April 2026), downloaded from USGS, maps 6,611 ground-mounted facilities of 1 MW or more linked to EIA plant codes. Under 1 MW there is no plant list: EIA gives estimates by state; LBNL's Tracking the Sun covers about 4.0 million systems by ZIP code, with no operator.","main_caveats":["Scope: EIA-860 and EIA-860M cover plants of 1 MW or more combined nameplate; 76 PV plants in the annual file have under 1 MW AC of PV (47 list other generators, 29 none). Small-scale PV has no EIA plant list.","Capacity: EIA nameplate is AC; DC at STC is in the solar sheet (198,471 MW DC against 152,848 MW AC). USPVDB threshold is on DC: 52 of 6,611 records have AC under 1 MW, none have DC under 1 MW.","Date: EIA 'Operating Month/Year' is initial commercial operation per generator; the plant date used here is the earliest. LBNL COD for Topaz (2014-10-31) matches the latest generator. USPVDB p_year is not independent of EIA.","Operator: 'Utility Name' is the company responsible for day-to-day operations, not the owner. 'Entity Name' in EIA-860M differs from it for 190 of 8,307 generators in annual plants.","Location: EIA gives a central point of the property; USPVDB v4.0 gives polygons and a representative point (median gap 0.22 km; 213 matched plants above 5 km; maximum 333 km).","Version: USPVDB v4.0 contains 6,611 facilities; 57 do not match any operating PV plant in the 2025 or September 2026 EIA files, and the EIA files hold 1,064 PV plants of 1 MW or more that v4.0 does not map."],"confidence":"medium","confidence_reason":"EIA-860 2025, EIA-860M (September 2026), USPVDB v4.0 and LBNL's utility-scale file were downloaded and checked. Under-1 MW PV was not tested at plant level; LBNL's distributed file was described, not downloaded.","attributes":[{"attribute":"location","covered":"partial","source_ids":["eia860-2025","eia860m-2026-09","uspvdb-4-0","lbnl-uss-2026","osm-generator-solar"],"note":"EIA plant/generator points; USPVDB v4.0 polygons and points (ground-mounted, 1 MW+); LBNL points above 5 MW AC. Precision not given in numbers.","gap":"not_published","gap_note":"Under 1 MW: no per-plant location in EIA files; LBNL's public file gives ZIP code only (guide read, file not downloaded). 213 of 6,553 USPVDB v4.0 records matched to EIA lie more than 5 km from the EIA point."},{"attribute":"capacity_mw","covered":"partial","source_ids":["eia860-2025","eia860m-2026-09","uspvdb-4-0","lbnl-uss-2026","eia-epm-62b"],"note":"AC nameplate per generator (EIA-860, 860M); DC at STC (EIA solar sheet, USPVDB, LBNL). Basis kept per field. EIA estimates small-scale AC by state.","gap":"not_published","gap_note":"Under 1 MW, capacity appears only as state estimates (EIA, 63,193 MW AC in August 2026) or as DC per system in LBNL's file (not downloaded). EIA plant scope is 1 MW combined nameplate or more."},{"attribute":"operator","covered":"partial","source_ids":["eia860-2025","eia860m-2026-09"],"note":"'Utility Name' (EIA-860) is the company running each plant day to day: 2,629 names at 7,309 plants. EIA-860M 'Entity Name' matches it for 97.7% of generators.","gap":"not_published","gap_note":"No operator for under-1 MW PV. USPVDB and LBNL's utility-scale file have no operator field. The EIA Ownership sheet (owners, separate from operator) lists 1,386 PV plants, 98 with several owners; not used as operator."},{"attribute":"commissioning_date","covered":"partial","source_ids":["eia860-2025","eia860m-2026-09","uspvdb-4-0","lbnl-uss-2026"],"note":"Month and year of initial commercial operation per generator (EIA). USPVDB p_year copies EIA; LBNL 'Solar COD' is a full date per project above 5 MW AC.","gap":"not_published","gap_note":"No per-plant date for under-1 MW PV in EIA; Tracking the Sun has an installation date, sometimes a proxy such as an incentive claim (guide read). Topaz: EIA first generator 04-2013, USPVDB 2014, LBNL COD 2014-10-31."}]},"sources":[{"source_id":"eia860-2025","name":"Annual Electric Generator Report, Form EIA-860, final 2025 data","publisher":"U.S. Energy Information Administration (EIA)","official":true,"landing_url":"https://www.eia.gov/electricity/data/eia860/","data_url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","access":"direct_download","format":"XLSX inside ZIP (23.6 MB)","license":"Public domain (EIA Copyrights and Reuse)","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Plant-level list of operating PV: plant code, coordinates, county, operator (Utility Name), AC nameplate, DC capacity (solar sheet), and commercial operation month and year.","first_seen_pass":1,"rank":1,"summary":"Official plant-level list of utility-scale operating PV (1 MW plant scope). Gives coordinates, operator, AC capacity, DC capacity and commercial operation month and year.","coverage_note":"Plants with total generator nameplate of 1 MW or more, PV in 49 states and DC. Small-scale PV under 1 MW is not listed per plant.","data_date":"2025-12-31","caveats":["Capacity is AC nameplate; DC is in a separate sheet.","Dates are month and year of commercial operation per generator, not authorisation dates.","Coordinates are a central point of the property, not a boundary."],"coverage":{"geographic":"PV plants in 49 states and DC (North Dakota has plants in the plant sheet but none with operating PV); no Puerto Rico plants in the annual files. Plants with total generator nameplate of 1 MW or more."},"fine_print":{"unit":{"value":"MW AC nameplate per generator, rounded to 0.1; DC MW at STC in the solar sheet","quote":"The total generator nameplate capacity is the sum of the AC ratings of the array.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","attempts":[]},"inclusion_rule":{"value":"Existing plants with total generator nameplate of 1 MW or more, connected to the grid","quote":"The plant’s total generator nameplate capacity is 1 Megawatt (MW) or greater and","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","attempts":[]},"reference_date":{"value":"Status as of 31 December 2025 (reporting year 2025)","quote":"if you are reporting data as of December 31, 2025, then the reporting year is 2025.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","attempts":[]},"update_frequency":{"value":"Annual final file (released in September); monthly supplement EIA-860M","quote":"September 10, 2026, Final 2025 data","url":"https://www.eia.gov/electricity/data/eia860/","attempts":[]},"exclusions":{"value":"Plants under 1 MW total nameplate (small-scale PV). Planned and retired generators are on other sheets.","quote":"Include generators with maximum capability of less than 1 MW if located at a plant with a total nameplate capacity of 1 MW or greater.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","attempts":[{"url":"https://www.eia.gov/todayinenergy/detail.php?id=31992","note":"EIA article of 11 July 2017 defines small-scale PV as under 1 MW. No per-plant list for small-scale PV was found."}]}},"key_fields":[{"field":"Plant Code","meaning":"EIA plant identifier. Joins sheets and matches USPVDB eia_id."},{"field":"Technology","meaning":"'Solar Photovoltaic' selects PV generators."},{"field":"Status","meaning":"'OP' means operating, in commercial operation. 'OA' and 'OS' are out of service."},{"field":"Nameplate Capacity (MW)","meaning":"AC nameplate per generator."},{"field":"DC Net Capacity (MW)","meaning":"Net DC capacity at STC (1000 W/m2, 25 °C), in the solar sheet."},{"field":"Operating Month / Operating Year","meaning":"Month and year the generator began commercial operation."},{"field":"Utility Name","meaning":"Legal name of the company responsible for day-to-day operations of the generator."},{"field":"Latitude / Longitude (Plant sheet)","meaning":"Coordinates of the plant, a central point within its property, in decimal degrees."}],"how_to_use":{"example_request":"Download https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip and extract it into an empty folder. Open 3_1_Generator_Y2025.xlsx, sheet 'Operable' (header on the third line), and keep Technology = 'Solar Photovoltaic' and Status = 'OP'. Join 2___Plant_Y2025.xlsx, sheet 'Plant', on Plant Code for coordinates.","example_result":"Topaz Solar Farm (Plant Code 57695), San Luis Obispo County, CA: 5 OP PV generators, 585.9 MW AC (752.1 MW DC), operator 'Topaz Solar Farms LLC', first generator in commercial operation 04-2013, point 35.405556, -120.068611.","steps":["1. Download the ZIP (23,622,347 bytes; SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba) and extract it into an empty folder.","2. Convert the XLSX sheets to CSV (GDAL ogr2ogr worked). Each sheet has a title line before the header.","3. Keep generators with Technology 'Solar Photovoltaic' and Status 'OP': 7,979 rows at 7,309 plants in this test.","4. Join by Plant Code to the Plant sheet for coordinates, county, state and Utility Name; join by Plant Code and Generator ID to the solar sheet for DC.","5. Take the commercial operation date from Operating Month and Operating Year (MM-YYYY) per generator; the plant date is the earliest of its generators."],"reading_traps":["Capacity in the generator sheet is AC nameplate. DC appears only in the solar sheet: 198,470.9 MW DC against 152,847.6 MW AC for the same operating set.","76 plants have PV under 1 MW AC. 47 also list other generators (for example gas turbines); 29 show none in this sheet, so their inclusion is not explained by this file.","'OA' (out of service, expected to return) and 'OS' (out of service, not expected to return) are not counted as operating: 15 and 5 PV generators in this file.","Coordinates are a central point of the property, not a boundary. Compare with USPVDB before using them as precise locations.","The Proposed sheet (planned generators) belongs to the permitting topic and was not used.","Plant sheet has 17,349 plants of all technologies; filter generators first. The Ownership sheet (4___Owner_Y2025.xlsx, sheet 'Ownership') covers 1,386 PV plants and lists owners, which can differ from 'Utility Name'."]},"test":{"tested_on":"2026-11-19","method":"download","http_status":200,"content_type":"application/x-zip-compressed","size_bytes":23622347,"records_total":27919,"records_for_country":7979,"problems":["records_total counts generator rows of the 'Operable' sheet (all technologies); records_for_country counts solar PV generators with status OP.","Sheets begin with a title line; GDAL names the columns Field1 to Field73 at first, and the real header is the third line.","The file reflects status at 31 December 2025. The monthly file (September 2026) gives a later count.","Revision of 2026-11-19: ZIP downloaded again (SHA-256 identical); 7,979 generators, 7,309 plants, 152,847.6 MW AC, 198,470.9 MW DC (one generator without DC), 2,629 Utility Names, 76 plants under 1 MW AC of PV, 15 OA and 5 OS reproduced with a stdlib XLSX reader."]},"evidence":[{"claim":"Scope: plants with total generator nameplate of 1 MW or more are required to respond.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"The plant’s total generator nameplate capacity is 1 Megawatt (MW) or greater and"},{"claim":"PV nameplate capacity is measured as AC.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"For photovoltaic solar, the total generator nameplate capacity is the sum of the AC ratings of the array."},{"claim":"Operating date is the initial commercial operation, entered as MM-YYYY.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"When did this generator begin commercial operation? Enter the month and year of initial commercial operation in the format MM-YYYY."},{"claim":"Status code OP means operating in commercial operation.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"Operating – in service (commercial operation)"},{"claim":"Utility Name is the company responsible for day-to-day operations.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"Legal name of the company that is responsible for the day-to-day operations of the generator"},{"claim":"Plant coordinates are a central point within the property, not a boundary.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"The coordinates should relate to a central point within the plant’s property such as a generator."},{"claim":"DC capacity is defined under standard test conditions.","url":"https://www.eia.gov/electricity/data/eia860/xls/eia8602025.zip","quote":"The net capacity of this photovoltaic generator in direct current under standard test conditions (STC) of 1000 W/m^2 solar irradiance and 25 degrees Celsius PV module temperature"},{"claim":"Small-scale PV (under 1 MW) is a separate EIA category, typically on rooftops.","url":"https://www.eia.gov/todayinenergy/detail.php?id=31992","quote":"EIA categorizes PV systems that have a generating capacity of less than one megawatt (MW), which are typically installed on business or residential rooftops, as small-scale systems."},{"claim":"EIA publications are in the public domain.","url":"https://www.eia.gov/about/copyrights_reuse.php","quote":"U.S. government publications are in the public domain and are not subject to copyright protection."},{"claim":"Final 2025 data were released on 10 September 2026.","url":"https://www.eia.gov/electricity/data/eia860/","quote":"September 10, 2026, Final 2025 data"}],"members":[],"members_summary":null},{"source_id":"eia860m-2026-09","name":"Monthly Electric Generator Inventory, Form EIA-860M, September 2026 file","publisher":"U.S. Energy Information Administration (EIA)","official":true,"landing_url":"https://www.eia.gov/electricity/data/eia860m/","data_url":"https://www.eia.gov/electricity/data/eia860m/xls/september_generator2026.xlsx","access":"direct_download","format":"XLSX (14.0 MB)","license":"Public domain (EIA Copyrights and Reuse)","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Most recent operating status: 8,335 operating PV generators at 7,651 plants in September 2026, with generator-level coordinates, DC capacity and operating month and year; Puerto Rico in separate sheets.","first_seen_pass":1,"rank":2,"summary":"Most recent EIA monthly status of operating generators. Lists PV generators with coordinates and commercial operation dates through September 2026.","coverage_note":"Generators at plants of 1 MW or more combined nameplate, United States; Puerto Rico in separate sheets (18 PV plants).","data_date":"2026-09","caveats":["Counts generators and plants separately.","Preliminary monthly estimates, corrected later without notice.","Entity Name differs from the annual Utility Name for 190 of 8,307 generators."],"coverage":{"geographic":"Sheet 'Operating': PV in 49 states and DC. Sheet 'Operating_PR' (Puerto Rico, included since March 2018): 19 operating PV generators at 18 plants, 164.7 MW."},"fine_print":{"unit":{"value":"MW nameplate per generator; equal to the AC nameplate of EIA-860 for 7,976 of the 7,979 PV generators present in both files (tested). DC at STC in 'DC Net Capacity (MW)'.","quote":null,"url":"https://www.eia.gov/electricity/data/eia860m/","attempts":[{"url":"https://www.eia.gov/electricity/data/eia860m/","note":"The landing page gives no unit statement and the EIA-860M form instructions were not opened. The AC basis is inferred from the numerical match with the annual file, not quoted."}]},"inclusion_rule":{"value":"Existing and proposed generators at plants with 1 MW or greater of combined nameplate capacity; Puerto Rico included since March 2018 data.","quote":"at electric power plants with 1 megawatt or greater of combined nameplate capacity","url":"https://www.eia.gov/electricity/data/eia860m/","attempts":[]},"reference_date":{"value":"Inventory as of September 2026; release dated 23 October 2026","quote":"Inventory of Operating Generators as of September 2026","url":"https://www.eia.gov/electricity/data/eia860m/xls/september_generator2026.xlsx","attempts":[]},"update_frequency":{"value":"Monthly; next release 24 November 2026","quote":"Next Release Date: November 24, 2026","url":"https://www.eia.gov/electricity/data/eia860m/","attempts":[]},"exclusions":{"value":"Plants under 1 MW combined nameplate. Capacities are preliminary estimates and are corrected without acknowledgement in later months.","quote":"reported capacities are EIA's preliminary estimates of capacity for that month. Estimates will be corrected without specific acknowledgment or explanation in subsequent month's inventory.","url":"https://www.eia.gov/electricity/data/eia860m/","attempts":[]}},"key_fields":[{"field":"Plant ID","meaning":"EIA plant identifier, equal to the annual Plant Code."},{"field":"Status","meaning":"'(OP) Operating', '(OA)' or '(OS)' for PV generators."},{"field":"Nameplate Capacity (MW)","meaning":"Generator nameplate in MW; equal to the annual AC nameplate for 7,976 of 7,979 shared PV generators."},{"field":"DC Net Capacity (MW)","meaning":"DC capacity, filled for 7,987 of 8,335 operating PV generators."},{"field":"Operating Month / Operating Year","meaning":"Month and year the generator began operating."},{"field":"Entity Name","meaning":"Reporting entity. Equals the annual 'Utility Name' for 8,117 of 8,307 generators at plants present in the annual file; not defined on the landing page."},{"field":"Latitude / Longitude","meaning":"Generator-level coordinates in decimal degrees (present in this file)."}],"how_to_use":{"example_request":"Download https://www.eia.gov/electricity/data/eia860m/xls/september_generator2026.xlsx. Convert sheet 'Operating' (header on the fourth line, starting 'Entity ID'). Keep Technology = 'Solar Photovoltaic' and Status starting with '(OP)'.","example_result":"Topaz Solar Farm (Plant ID 57695), generator TPZ1: 129.8 MW nameplate, 166 MW DC, operating month 4 and year 2013, latitude 35.405556, longitude -120.0686, entity 'Topaz Solar Farms LLC'. The five generators sum to 585.9 MW.","steps":["1. Download the XLSX (14,013,970 bytes) into an empty folder.","2. Convert the 'Operating' sheet with GDAL or an XLSX reader; skip the title and blank lines.","3. Keep PV generators with Status beginning '(OP)': 8,335 generators at 7,651 plants in this test.","4. Use the generator-level Latitude and Longitude directly; no join is needed for location.","5. Read sheet 'Operating_PR' for Puerto Rico: 230 operating generators of all technologies, 19 PV, 18 plants, 164.7 MW."],"reading_traps":["The file counts generators, not plants: 8,335 operating PV generators against 7,651 plant IDs.","The monthly file is later than the annual one: 339 operating PV generators carry an operating year of 2026.","'(OA)' (15) and '(OS)' (5) PV generators are not operating.","Puerto Rico is not in sheet 'Operating': national totals from that sheet exclude it.","Scope is 1 MW combined nameplate: 78 plants in this file have under 1 MW of PV, as other generators lift the plant above the threshold."]},"test":{"tested_on":"2026-11-19","method":"download","http_status":200,"content_type":null,"size_bytes":14013970,"records_total":28485,"records_for_country":8335,"problems":["The HTTP content type was not recorded for this download.","The 'Operating' sheet has a title line and a blank line before the header; the real header starts 'Entity ID'.","Revision of 2026-11-19: file downloaded again (14,013,970 bytes) and counts reproduced: 8,335 PV generators, 7,651 plants, 170,562.5 MW AC, 2,741 entity names, 339 with operating year 2026; Puerto Rico sheets read.","The page lists a release dated 23 October 2026 for the September 2026 inventory and a next release on 24 November 2026; the October file URL returned a redirect to the EIA electricity page and no file."]},"evidence":[{"claim":"Operating-generator inventory for September 2026.","url":"https://www.eia.gov/electricity/data/eia860m/xls/september_generator2026.xlsx","quote":"Inventory of Operating Generators as of September 2026"},{"claim":"The monthly release was dated 23 October 2026.","url":"https://www.eia.gov/electricity/data/eia860m/","quote":"Release Date: October 23, 2026"},{"claim":"EIA-860M is a supplement to Form EIA-860.","url":"https://www.eia.gov/electricity/data/eia860m/","quote":"(based on Form EIA-860M as a supplement to Form EIA-860)"},{"claim":"Scope threshold of EIA-860M: 1 MW combined nameplate.","url":"https://www.eia.gov/electricity/data/eia860m/","quote":"at electric power plants with 1 megawatt or greater of combined nameplate capacity"},{"claim":"Puerto Rico is included in the monthly inventory since March 2018.","url":"https://www.eia.gov/electricity/data/eia860m/","quote":"Starting with March 2018 data, the Preliminary Monthly Electric Generator Inventory also includes data from Puerto Rico"},{"claim":"Monthly capacities are preliminary estimates.","url":"https://www.eia.gov/electricity/data/eia860m/","quote":"reported capacities are EIA's preliminary estimates of capacity for that month"}],"members":[],"members_summary":null},{"source_id":"uspvdb-4-0","name":"U.S. Large-Scale Solar Photovoltaic Database (USPVDB), version 4.0 (14 April 2026)","publisher":"U.S. Geological Survey (USGS) Energy Resources Program, with Lawrence Berkeley National Laboratory (DOE)","official":true,"landing_url":"https://energy.usgs.gov/uspvdb/","data_url":"https://energy.usgs.gov/uspvdb/assets/data/uspvdbCSV.zip","access":"direct_download","format":"CSV (zip 366 KB), shapefile (zip 7.8 MB), GeoJSON (zip 9.5 MB), FGDC XML metadata, ArcGIS FeatureServer","license":"Public domain; USGS asks for an acknowledgement statement (page 'License and Attribution')","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Current USGS release: 6,611 ground-mounted PV facilities of 1 MW or more with array polygons, representative points, EIA plant code, aerial image date, digitising confidence, AC and DC capacity and start year. Downloadable from USGS and queryable by a REST service.","first_seen_pass":2,"rank":3,"summary":"USGS and LBNL geospatial database of ground-mounted PV of 1 MW or more: array polygons, points, EIA plant code, capacities and start year. Version 4.0 downloaded and its service queried.","coverage_note":"6,611 facilities in 49 states and DC, first operation 1985 to Q4 2025; releases lag installations by more than a year.","data_date":"2026-04-14","caveats":["Capacities and year come from EIA-860; year is not an independent date.","57 records match no operating PV plant in the EIA files tested; 1,064 EIA PV plants of 1 MW or more are not mapped.","No operator field."],"coverage":{"geographic":"49 states and DC (no facility in North Dakota). Ground-mounted PV of 1 MW or more; first operation 1985, latest 2025 (fourth quarter 2025 per the page)."},"fine_print":{"unit":{"value":"MW AC (p_cap_ac) and MW DC (p_cap_dc), both from EIA Form 860; p_area in square metres","quote":"Facility capacity in megawatts DC (Direct Current) from EIA Form 860.","url":"https://energy.usgs.gov/uspvdb/assets/data/uspvdb_v4_0_20260414.xml","attempts":[]},"inclusion_rule":{"value":"PV facilities with capacity of 1 MW or more, ground-mounted. The threshold is applied to DC: 52 records have AC under 1 MW and none has DC under 1 MW.","quote":"provides the locations and array boundaries of U.S. photovoltaic (PV) facilities with capacity of 1 megawatt or more","url":"https://energy.usgs.gov/uspvdb/","attempts":[]},"reference_date":{"value":"Release USPVDB_V4_0_20260414 of 14 April 2026; aerial image dates 2009-04-17 to 2026-02-08; most recent facilities began operating in the fourth quarter of 2025","quote":"Latest Database Release Version: USPVDB_V4_0_20260414","url":"https://energy.usgs.gov/uspvdb/","attempts":[]},"update_frequency":{"value":"Public releases in the changelog: 1.0 (2023-11-08), 2.0 (2024-08-01), 3.0 (dated 2024-04-29, out of sequence; the data.gov listing says April 2025), 4.0 (2026-04-14); releases lag installations by more than a year","quote":"USPVDB releases generally lag installations by more than a year","url":"https://energy.usgs.gov/uspvdb/","attempts":[{"url":"https://energy.usgs.gov/uspvdb/assets/data/CHANGELOG.txt","note":"The changelog lists 3.0 on 2024-04-29, before 2.0 (2024-08-01); the date looks like a typo for April 2025, which matches the data.gov listing read in pass 1. Not confirmed."}]},"exclusions":{"value":"Facilities under 1 MW (DC). 4 facility records under the threshold were removed in v4.0. Rooftop systems are outside the 'ground-mounted' scope of the Zenodo description of earlier versions; the USGS page states no explicit rooftop rule.","quote":"4 facility records determined to be under the capacity threshold of 1MW.","url":"https://energy.usgs.gov/uspvdb/assets/data/CHANGELOG.txt","attempts":[]}},"key_fields":[{"field":"eia_id","meaning":"EIA Form 860 plant code. 6,553 of 6,611 records match an operating PV plant in the 2025 annual file."},{"field":"ylat / xlong","meaning":"Representative point of the facility, NAD83, decimal degrees."},{"field":"p_area","meaning":"Area of arrays and inverters in m2."},{"field":"p_img_date","meaning":"Acquisition date of the aerial image used to confirm location (yyyymmdd)."},{"field":"p_dig_conf","meaning":"Confidence 1 (multi-phase or several EIA records at one place) to 4 (high); 4: 6,264, 2: 216, 3: 92, 1: 39 records."},{"field":"p_year","meaning":"Year the facility began operating, from EIA Form 860."},{"field":"p_cap_ac / p_cap_dc","meaning":"Capacity in MW AC and MW DC from EIA Form 860."},{"field":"p_comm","meaning":"'community solar' for 1,101 records; blank otherwise."}],"how_to_use":{"example_request":"Download https://energy.usgs.gov/uspvdb/assets/data/uspvdbCSV.zip, extract it into an empty folder and read uspvdb_v4_0_20260414.csv. Or query https://energy.usgs.gov/arcgis/rest/services/Hosted/uspvdbDyn/FeatureServer/0/query with where=1=1, returnCountOnly=true and f=json.","example_result":"The service answered {\"count\":6611}. In the CSV, case_id 400246, Topaz Solar Farm (eia_id 57695), San Luis Obispo CA: p_cap_ac 585.9, p_cap_dc 752.1, p_year 2014, p_img_date 20210803, p_dig_conf 4, point 35.3722, -120.0558.","steps":["1. Download uspvdbCSV.zip (366,335 bytes; SHA-256 3bc862e6988aa1474c55dab656bfc0e74bd8e4609ed2cec0bbce21091a0219fa) into an empty folder and extract it.","2. Read uspvdb_v4_0_20260414.csv (6,611 rows, 26 columns). Use the XML metadata for definitions.","3. Join eia_id to the EIA Plant Code (annual) or Plant ID (monthly) for operator and generator detail; USPVDB has no operator.","4. For polygons download the shapefile or GeoJSON zip, or use the FeatureServer. Check p_dig_conf before using p_area."],"reading_traps":["p_year equals the earliest EIA operating year for 6,268 of 6,553 matched plants; Topaz shows 2014 against EIA 04-2013.","The representative point and the EIA central point differ: median 0.22 km, 213 plants above 5 km, 333 km for eia_id 65104.","57 records match no operating PV plant in the 2025 annual or the September 2026 monthly file; 1,064 EIA PV plants of 1 MW or more are not in the database.","The download page says the GeoJSON zip is about 2 MB and the CSV zip about 2 MB; the files are 9.5 MB and 0.37 MB."]},"test":{"tested_on":"2026-11-19","method":"download","http_status":200,"content_type":"application/x-zip-compressed","size_bytes":366335,"records_total":6611,"records_for_country":6611,"problems":["Downloaded from USGS: CSV, shapefile and GeoJSON zips, XML metadata and changelog (HTTP 200). The shapefile and GeoJSON were downloaded but not opened.","The FeatureServer count query returned 6,611, equal to the CSV.","ScienceBase (doi.org/10.5066/P9IA3TUS and the catalog item) still returned HTTP 403 to this client; the data release page there was not read.","The changelog dates version 3.0 on 2024-04-29, before version 2.0 (2024-08-01); the date is probably a typo and was not confirmed."]},"evidence":[{"claim":"Current release and facility count.","url":"https://energy.usgs.gov/uspvdb/","quote":"The latest release includes data on 6,611 facilities covering 49 states (plus the District of Columbia)."},{"claim":"Inclusion threshold of 1 MW.","url":"https://energy.usgs.gov/uspvdb/","quote":"provides the locations and array boundaries of U.S. photovoltaic (PV) facilities with capacity of 1 megawatt or more"},{"claim":"Public domain with an acknowledgement request.","url":"https://energy.usgs.gov/uspvdb/","quote":"Map services and data downloaded from the U.S. Large-Scale Solar Photovoltaic Database are free and in the public domain."},{"claim":"p_year is taken from EIA Form 860.","url":"https://energy.usgs.gov/uspvdb/assets/data/uspvdb_v4_0_20260414.xml","quote":"Year the facility began operating from EIA form 860."},{"claim":"Representative point definition.","url":"https://energy.usgs.gov/uspvdb/assets/data/uspvdb_v4_0_20260414.xml","quote":"Representative points are a single point intended to reflect the location of facility panels as accurately as possible."},{"claim":"Release lag.","url":"https://energy.usgs.gov/uspvdb/","quote":"USPVDB releases generally lag installations by more than a year"},{"claim":"Records added and removed in v4.0.","url":"https://energy.usgs.gov/uspvdb/assets/data/CHANGELOG.txt","quote":"903 facility records."}],"members":[],"members_summary":null},{"source_id":"lbnl-uss-2026","name":"Utility-Scale Solar, 2026 Edition: public data file (tab 'Individual_Project_Data')","publisher":"Lawrence Berkeley National Laboratory (DOE), Energy Markets and Policy","official":true,"landing_url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","data_url":"https://eta-publications.lbl.gov/sites/default/files/2026-10/utility_scale_solar_2026_edition_datafile.xlsx","access":"direct_download","format":"XLSX (62.9 MB, 61 tabs)","license":"Unknown","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Project-level table of 1,989 ground-mounted PV projects above 5 MW AC installed through 2025, with EIA ID, coordinates, DC and AC capacity and a commercial operation date; no operator or developer column.","first_seen_pass":2,"rank":4,"summary":"LBNL project table of ground-mounted PV above 5 MW AC with EIA ID, point, AC and DC capacity and commercial operation date.","coverage_note":"1,989 PV projects through 2025; no operator column.","data_date":"2025-12-31","caveats":["Above 5 MW AC only.","No operator."],"coverage":{"geographic":"United States; ground-mounted PV and PV+battery projects larger than 5 MW AC, plus 16 CSP plants, installed through 2025."},"fine_print":{"unit":{"value":"MW-AC and MW-DC per project ('Solar Capacity MW-AC', 'Solar Capacity MW-DC')","quote":null,"url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","attempts":[{"url":"https://eta-publications.lbl.gov/sites/default/files/2026-10/user_guide_for_utility-scale_solar_generation_and_market_value_data_file_2026.pdf","note":"The guide read covers the hourly-generation files, not this tab; units come from the column names."}]},"inclusion_rule":{"value":"Ground-mounted systems larger than 5 MW AC; smaller projects are in the distributed update","quote":"The focus is on ground-mounted systems larger than 5M AC","url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","attempts":[]},"reference_date":{"value":"Projects installed through 2025; published October 2026","quote":"The latest update contains project-level data on 1,989 solar projects installed through 2025.","url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","attempts":[]},"update_frequency":{"value":"Annual","quote":null,"url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","attempts":[{"url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","note":"No schedule is stated; the 2025 and 2026 editions exist. Annual is inferred."}]},"exclusions":{"value":"Projects of 5 MW AC or less; non-confidential data only (the page says the file holds non-confidential data)","quote":"A Public data file with non-confidential data on 60 tabs","url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","attempts":[]}},"key_fields":[{"field":"EIA ID","meaning":"EIA plant code; retired plants carry a 'ret' suffix."},{"field":"Solar COD / Solar COD Year","meaning":"Commercial operation date as an Excel serial number, and its year."},{"field":"Latitude / Longitude","meaning":"Project point in decimal degrees."},{"field":"Solar Capacity MW-DC / MW-AC","meaning":"Project capacity on each basis."},{"field":"Offtaker Type","meaning":"Buyer category (for example investor-owned utility); not an operator."}],"how_to_use":{"example_request":"Download the XLSX, open tab 'Individual_Project_Data' (header on the first line) and filter 'Solar Tech Main' = PV and 'EIA ID' without the 'ret' suffix.","example_result":"EIA ID 57695, 'Topaz Solar Farm Phase 1-3', CA: Solar COD 41943 (2014-10-31), 757.9 MW-DC, 585.9 MW-AC, point 35.37234, -120.05654.","steps":["1. Download the XLSX (62,885,230 bytes; SHA-256 d3eccb46ec10c9b71cb77314908ad6ac11ebf83d5eac976492801029903ab341).","2. Read tab 'Individual_Project_Data': 2,005 rows, 1,989 PV and 16 CSP.","3. Convert 'Solar COD' from an Excel serial number to a date.","4. Join 'EIA ID' to the EIA Plant Code for operator."],"reading_traps":["The smallest PV project is 5.001 MW AC: nothing under 5 MW AC is listed.","DC for Topaz is 757.9 MW here, 752.1 MW in EIA and USPVDB.","COD is a single project date; for Topaz it matches the latest EIA generator, while EIA's earliest generator is 04-2013."]},"test":{"tested_on":"2026-11-19","method":"download","http_status":200,"content_type":"application/vnd.openxmlformats-officedocument.spreadsheetml.sheet","size_bytes":62885230,"records_total":2005,"records_for_country":1989,"problems":["emp.lbl.gov returned HTTP 403 again; the same publication is served from eta-publications.lbl.gov and was read there.","Only tab 'Individual_Project_Data' was read; the other 60 tabs are aggregates.","No developer, owner or operator column exists in the tab."]},"evidence":[{"claim":"Scope above 5 MW AC and count of projects.","url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","quote":"The latest update contains project-level data on 1,989 solar projects installed through 2025."},{"claim":"Smaller projects belong to the distributed update.","url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","quote":"smaller projects are covered in Berkeley Lab's separate U.S. Distributed Solar and Storage annual data update"}],"members":[],"members_summary":null},{"source_id":"lbnl-tts-2026","name":"U.S. Distributed Solar and Storage Data: 2026 Update (Tracking the Sun public data file)","publisher":"Lawrence Berkeley National Laboratory (DOE), Energy Markets and Policy","official":true,"landing_url":"https://eta-publications.lbl.gov/publications/us-distributed-solar-and-storage-0","data_url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","access":"direct_download","format":"CSV public data file (linked from the user guide through a Google Drive address) and PDF user guide","license":"Unknown","language":"en","has_coordinates":false,"location_precision":"address","publisher_type":"national_government","adds":"Only plant-level source found for PV under 1 MW: about 4.0 million grid-connected residential and non-residential systems installed through 2025, with state, ZIP code, installation date and DC size. Described and read in the user guide; the data file was not downloaded.","first_seen_pass":2,"rank":5,"summary":"LBNL's public file of about 4.0 million distributed PV systems, with state, ZIP code, installation date and DC size. Read in the guide; the file was not downloaded.","coverage_note":"Rooftop and small ground-mounted systems through 2025; ZIP code, no operator.","data_date":"2025-12-31","caveats":["Described, not downloaded.","ZIP code only; no operator.","Installation date may be a proxy."],"coverage":{"geographic":"United States; rooftop systems of any size and ground-mounted systems up to 7 MW DC (user guide) or 5 MW AC (landing page)."},"fine_print":{"unit":{"value":"kW DC at standard test conditions per system (PV_system_size_DC)","quote":"The total rated direct-current (DC) output of the module arrays at standard test conditions.","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","attempts":[]},"inclusion_rule":{"value":"Grid-connected rooftop systems of any size and ground-mounted systems up to 7 MW DC","quote":"ground-mounted systems up to 7 MWDC","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","attempts":[{"url":"https://eta-publications.lbl.gov/publications/us-distributed-solar-and-storage-0","note":"The landing page says ground-mounted systems up to 5 MW-AC; the two thresholds differ and were not reconciled."}]},"reference_date":{"value":"Systems installed through year-end 2025; update of August 2026","quote":"The current version of the public data file includes about 4.0 million PV systems installed through","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","attempts":[]},"update_frequency":{"value":"Annual, with possible interim updates","quote":"The public project-level dataset is updated once annually with data from the previous calendar year","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","attempts":[]},"exclusions":{"value":"Data provided under confidentiality agreements; most fields are incomplete for most systems","quote":"The public data file excludes any data provided under confidentiality agreements","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","attempts":[]}},"key_fields":[{"field":"installation_date","meaning":"Installation date; for some providers a proxy such as an incentive claim or inspection date."},{"field":"PV_system_size_DC","meaning":"System size in kW DC."},{"field":"zip_code / state","meaning":"Host customer ZIP code and state: the location detail published."},{"field":"installer_name","meaning":"Installer; the file has no field for the operator of the system."},{"field":"data_provider_1","meaning":"Utility or incentive programme that supplied the record."}],"how_to_use":{"example_request":"Read the user guide at the data_url; it links the CSV public file through https://bit.ly/trackingthesun2026, which redirected (HTTP 301) to a Google Drive file. The file was not downloaded.","example_result":"Not obtained: the CSV was not opened. The guide lists 81 fields and states about 4.0 million systems; the landing page says roughly 5.3 million systems in the full dataset.","steps":["1. Open the landing page and the user guide PDF (926,394 bytes).","2. Follow the CSV link in the guide to the public data file and check its size before downloading.","3. Missing values are coded -1."],"reading_traps":["Public file (about 4.0 million systems) is smaller than the full dataset (about 5.3 million).","Location is a ZIP code, not coordinates; there is no operator field.","Missing data are coded as -1."]},"test":{"tested_on":"2026-11-19","method":"page_only","http_status":200,"content_type":"text/html; charset=UTF-8","size_bytes":19412,"records_total":null,"records_for_country":null,"problems":["Landing page and user guide read; the CSV was not downloaded, so field names, counts and the ZIP code field come from the guide.","emp.lbl.gov and trackingthesun.lbl.gov (redirect to emp.lbl.gov/tracking-the-sun/) returned HTTP 403.","Next step: download the CSV from the Google Drive link and count systems under 1 MW by state."]},"evidence":[{"claim":"Public file size and period.","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","quote":"The current version of the public data file includes about 4.0 million PV systems installed through"},{"claim":"Scope in the guide.","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","quote":"ground-mounted systems up to 7 MWDC"},{"claim":"Full dataset size on the landing page.","url":"https://eta-publications.lbl.gov/publications/us-distributed-solar-and-storage-0","quote":"The latest update contains data on roughly 5.3 million individual systems installed through the end of 2025"}],"members":[],"members_summary":null},{"source_id":"eia-epm-62b","name":"Electric Power Monthly, Table 6.2.B: capacity by state, utility-scale and estimated small-scale solar PV","publisher":"U.S. Energy Information Administration (EIA)","official":true,"landing_url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","data_url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","access":"direct_download","format":"HTML table (EIA data browser)","license":"Public domain (EIA Copyrights and Reuse)","language":"en","has_coordinates":false,"location_precision":"none","publisher_type":"national_government","adds":"State and national estimates of small-scale (under 1 MW) PV capacity, from the monthly utility survey; 63,193 MW in August 2026. Aggregates only, no installations.","first_seen_pass":2,"rank":6,"summary":"EIA's monthly table of estimated small-scale (under 1 MW) PV capacity by state: 63,193 MW in the U.S. in August 2026. Aggregates, no installation list.","coverage_note":"States and U.S. total, August 2026 and August 2025.","data_date":"2026-08","caveats":["Estimates from a utility sample.","No installation, operator or date."],"coverage":{"geographic":"United States by census division and state, August 2026 and August 2025."},"fine_print":{"unit":{"value":"Megawatts; small-scale capacity is based on reported AC capacity","quote":"Small-scale solar photovoltaic (PV) data are based on reported alternating current (AC) capacity","url":"https://www.eia.gov/todayinenergy/detail.php?id=31992","attempts":[]},"inclusion_rule":{"value":"Estimated small-scale PV, defined by EIA as systems under 1 MW","quote":"EIA categorizes PV systems that have a generating capacity of less than one megawatt (MW)","url":"https://www.eia.gov/todayinenergy/detail.php?id=31992","attempts":[]},"reference_date":{"value":"August 2026 (2026 values preliminary, 2025 final)","quote":"Values for 2025 are final. Values for 2026 are preliminary.","url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","attempts":[]},"update_frequency":{"value":"Monthly; release of 23 October 2026, next on 24 November 2026","quote":"Release Date: October 23, 2026 Next Release Date: November 24, 2026","url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","attempts":[]},"exclusions":{"value":"Individual installations are not listed","quote":null,"url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","attempts":[{"url":"https://www.eia.gov/electricity/data/eia861m/","note":"The estimate rests on Form EIA-861M, a sample of utilities; no per-installation list is published there."}]}},"key_fields":[{"field":"Estimated Solar Photovoltaic (small scale)","meaning":"Estimated small-scale PV capacity in MW per state."},{"field":"Solar Photovoltaic (utility scale)","meaning":"Net summer capacity of utility-scale PV from EIA-860 and EIA-860M."}],"how_to_use":{"example_request":"Open https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b and read the row 'U.S. Total'.","example_result":"U.S. Total, August 2026: estimated small-scale solar PV 63,192.6 MW (August 2025: 56,666.5); utility-scale PV 166,677.0 MW net summer (August 2025: 139,535.3).","steps":["1. Open the table.","2. Read the columns 'Estimated Solar Photovoltaic' per state and for the U.S. total.","3. Do not add it to EIA-860 totals without checking that utility-scale values are net summer capacity."],"reading_traps":["Estimates, not records: no installation, operator or date.","Utility-scale column is net summer capacity, not nameplate AC (166,677 MW in August against 170,562 MW nameplate in September)."]},"test":{"tested_on":"2026-11-19","method":"page_only","http_status":200,"content_type":"text/html; charset=UTF-8","size_bytes":161495,"records_total":null,"records_for_country":null,"problems":["Only Table 6.2.B was read; the EIA-861M detailed files (net metering, small-scale estimate) were not downloaded."]},"evidence":[{"claim":"Estimates are AC-based.","url":"https://www.eia.gov/todayinenergy/detail.php?id=31992","quote":"Small-scale solar photovoltaic (PV) data are based on reported alternating current (AC) capacity"},{"claim":"Source forms of the table.","url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","quote":"Sources: U.S. Energy Information Administration, Form EIA-860, 'Annual Electric Generator Report' and Form EIA-860M"}],"members":[],"members_summary":null},{"source_id":"uspvdb-2024","name":"U.S. Large-Scale Solar Photovoltaic Database (USPVDB), version 2.0 (August 2024)","publisher":"U.S. Geological Survey (USGS) Energy Resources Program, with Lawrence Berkeley National Laboratory (DOE)","official":true,"landing_url":"https://doi.org/10.5066/P9IA3TUS","data_url":"https://zenodo.org/api/records/14736300/files/usgsuspvdb-2.0.zip/content","access":"direct_download","format":"CSV (4,185 rows) plus nested ZIP of geospatial files and FGDC XML metadata","license":"Public domain (per Zenodo record 'other-pd'; the USGS page was not reachable)","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"national_government","adds":"Archived copy of USPVDB v2.0 (August 2024) at Zenodo, tested in the first pass. Superseded by v4.0 (April 2026), which is the current USGS release; kept for comparison and as an independent archive.","first_seen_pass":1,"rank":7,"summary":"Superseded: archive copy of USPVDB v2.0 (2024) at Zenodo. See USPVDB v4.0 for the current release.","coverage_note":"4,185 facilities in 48 states, ground-mounted and 1 MW (DC) or more. Built on EIA-860 capacities and years of an earlier vintage.","data_date":"2024-08-07","caveats":["Superseded by v4.0 (April 2026): 6,611 records against 4,185 here.","Third-party archive of USGS data."],"coverage":{"geographic":"Ground-mounted PV facilities of 1 MW or more (threshold applied to DC). 48 distinct states in v2.0."},"fine_print":{"unit":{"value":"MW AC (p_cap_ac) and MW DC (p_cap_dc), both from EIA Form 860; array area in square metres (p_area)","quote":"facility capacity in megawatts AC (Alternating Current) from EIA Form 860","url":"https://zenodo.org/records/14736300","attempts":[]},"inclusion_rule":{"value":"Ground-mounted PV facilities with capacity of 1 MW or more","quote":"provides the locations and array boundaries of U.S. ground-mounted photovoltaic (PV) facilities with capacity of 1 megawatt or more","url":"https://zenodo.org/records/14736300","attempts":[]},"reference_date":{"value":"Aerial image dates from 2009-04-17 to 2024-05-26; dataset version dated 2024-08-07","quote":"acquisition date of the aerial image used to confirm the facility location and geometry","url":"https://zenodo.org/records/14736300","attempts":[]},"update_frequency":{"value":null,"quote":null,"url":"https://catalog.data.gov/dataset/united-states-large-scale-solar-photovoltaic-database-ver-3-0-april-2025","attempts":[{"url":"https://catalog.data.gov/dataset/united-states-large-scale-solar-photovoltaic-database-ver-3-0-april-2025","note":"The catalogue page opened lists version 3.0 (April 2025). A listing seen in search results shows version 4.0 (April 2026). Neither was downloaded: the USGS pages returned HTTP 403."}]},"exclusions":{"value":"Facilities under 1 MW DC are excluded. Two facilities under the 1 MW threshold were removed in v2.0.","quote":"2 facilities determined to be under the capacity threshold of 1MW.","url":"https://zenodo.org/records/14736300","attempts":[]}},"key_fields":[{"field":"eia_id","meaning":"EIA Form 860 plant code. Joins to the annual Plant Code."},{"field":"ylat / xlong","meaning":"Representative point (one point reflecting panel location), NAD83, decimal degrees."},{"field":"p_area","meaning":"Area of arrays and inverters in m2; buildings and fences excluded."},{"field":"multi_poly","meaning":"'single' or 'multi' polygon for the facility."},{"field":"p_img_date","meaning":"Acquisition date of the aerial image used to confirm location (yyyymmdd)."},{"field":"p_dig_conf","meaning":"Location confidence from 1 (lowest) to 4 (highest)."},{"field":"p_year","meaning":"Year operation began, taken from EIA Form 860."},{"field":"p_cap_ac / p_cap_dc","meaning":"Capacity in MW AC and MW DC, taken from EIA Form 860."}],"how_to_use":{"example_request":"Download usgsuspvdb-2.0.zip from Zenodo (MD5 370720806e01053be0cddfbdceffd546), extract it into an empty folder and read uspvdb_v2_0_20240807.csv. Keep eia_id to join with EIA-860 Plant Code.","example_result":"case_id 400246, Topaz Solar Farm (eia_id 57695), San Luis Obispo County, CA: p_cap_ac 585.9, p_cap_dc 752.1, p_year 2014, p_area 12,480,866 m2, p_img_date 2021-07-17, p_dig_conf 4, point 35.368633, -120.03261 (5.2 km from the EIA plant point).","steps":["1. Download the Zenodo archive (4,419,222 bytes) and check its MD5 against the record.","2. Extract it into an empty folder and treat the files as data.","3. Read uspvdb_v2_0_20240807.csv (4,185 rows). The dictionary file is an XLSX with a .csv name; convert it before reading.","4. Join on eia_id to the EIA Plant Code for operator and capacity checks (4,157 of 4,185 records matched in this test)."],"reading_traps":["p_year equals the earliest EIA operating year in 3,889 of 4,157 matched plants, but Topaz shows 2014 against EIA 04-2013.","The representative point and the EIA central point differ: median 0.23 km, 118 plants above 5 km, and 224.9 km for eia_id 61089.","The dictionary (July 2024) names some columns differently from the CSV headers (p_fac for p_name, p_reg for p_pwr_reg, p_batt for p_battery).","22 records have AC capacity under 1 MW; all have DC capacity of at least 1 MW, so the threshold is on DC."]},"test":{"tested_on":"2026-11-19","method":"download","http_status":200,"content_type":null,"size_bytes":4419222,"records_total":4185,"records_for_country":4185,"problems":["USGS and ScienceBase pages returned HTTP 403 to this client (DOI resolution included). The test used the Zenodo archive, a third-party copy of v2.0 (Catalyst Cooperative).","The HTTP content type was not recorded for this download.","The archive contains the data version of August 2024; the current USGS version was not tested.","Revision of 2026-11-19: USGS now answers (HTTP 200) and v4.0 was downloaded from USGS; this archive was not downloaded again."]},"evidence":[{"claim":"Inclusion rule: ground-mounted PV of 1 MW or more, with array boundaries.","url":"https://zenodo.org/records/14736300","quote":"provides the locations and array boundaries of U.S. ground-mounted photovoltaic (PV) facilities with capacity of 1 megawatt or more"},{"claim":"eia_id is the EIA Form 860 identifier for cross-reference.","url":"https://zenodo.org/records/14736300","quote":"unique facility identifier from EIA Form 860 for cross-reference to the EIA"},{"claim":"p_year is taken from EIA Form 860.","url":"https://zenodo.org/records/14736300","quote":"year in which facility operation began from EIA Form 860"},{"claim":"Representative point definition.","url":"https://zenodo.org/records/14736300","quote":"Representative points are a single point intended to reflect the location of facility panels as accurately as possible."},{"claim":"Location confidence scale from 1 to 4.","url":"https://zenodo.org/records/14736300","quote":"level of confidence in site location from 1 to 4"}],"members":[],"members_summary":null},{"source_id":"osm-generator-solar","name":"OpenStreetMap solar generator polygons (Overpass API query)","publisher":"OpenStreetMap contributors","official":false,"landing_url":"https://www.openstreetmap.org/","data_url":"https://overpass-api.de/api/interpreter","access":"api","format":"JSON (Overpass API)","license":"ODbL (© OpenStreetMap contributors)","language":"en","has_coordinates":true,"location_precision":"exact","publisher_type":"community","adds":"Crowd-mapped polygons of solar generators, including some small installations. Gives geometry without operator, capacity or date in the sample tested.","first_seen_pass":1,"rank":8,"summary":"Crowd-mapped solar generator polygons. In the one box tested, they carried no operator, capacity or date tags.","coverage_note":"Global, varies by area. Tested in one box around Topaz Solar Farm (21 elements).","data_date":"2026-11-19","caveats":["Polygons without operator, capacity or date in the sample.","Completeness not measured."],"coverage":{"geographic":"Global, crowd-mapped; completeness varies by area. Tested only in a box around Topaz Solar Farm, California."},"fine_print":{"unit":{"value":null,"quote":null,"url":"https://wiki.openstreetmap.org/wiki/Key:generator:source","attempts":[{"url":"https://wiki.openstreetmap.org/wiki/Key:generator:source","note":"Tag documentation was not opened. The sample carries no capacity tag."}]},"inclusion_rule":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://overpass-api.de/api/interpreter","note":"The query selected ways and relations tagged power=generator and generator:source=solar. No inclusion rule for small installations was checked."}]},"reference_date":{"value":"Snapshot of 2026-11-19 11:30 UTC (Overpass base timestamp)","quote":"2026-11-19T11:30:39Z","url":"https://overpass-api.de/api/interpreter","attempts":[]},"update_frequency":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://overpass-api.de/api/interpreter","note":"Continuous editing; no release calendar applies."}]},"exclusions":{"value":null,"quote":null,"url":null,"attempts":[{"url":"https://overpass-api.de/api/interpreter","note":"Exclusions are not published as a rule; the sample shows polygons without operator or capacity tags."}]}},"key_fields":[{"field":"generator:source","meaning":"'solar' marks a solar generator."},{"field":"geometry (way centre)","meaning":"Centre point of the mapped polygon; the sample gives centres only."}],"how_to_use":{"example_request":"POST or GET https://overpass-api.de/api/interpreter with a bounding box query: way[\"power\"=\"generator\"][\"generator:source\"=\"solar\"](35.33,-120.12,35.46,-120.00); out tags center. Send a generic client identifier: the first request without one returned HTTP 406.","example_result":"21 elements with tag generator:source=solar in the box around Topaz Solar Farm, for example way 320755088 at 35.3877, -120.0608. No operator, capacity or start date tags in the sample.","steps":["1. Run the bounding-box query above with a generic client identifier.","2. Read the element centres and tags; treat polygons as mapped geometry only.","3. Check operator, capacity and date against EIA-860 or USPVDB before using."],"reading_traps":["Crowd-sourced geometry: completeness and date of mapping are not documented here.","Absence of a tag (operator, capacity, start date) in the sample is not evidence that the value does not exist elsewhere."]},"test":{"tested_on":"2026-11-19","method":"api_query","http_status":200,"content_type":"application/json","size_bytes":4086,"records_total":21,"records_for_country":null,"problems":["The first request with the default client identifier returned HTTP 406 (nginx). A generic client identifier returned HTTP 200.","Test limited to a 0.13 by 0.12 degree box around Topaz Solar Farm; no national test."]},"evidence":[{"claim":"OSM data are under the Open Database License.","url":"https://overpass-api.de/api/interpreter","quote":"The data is made available under ODbL."}],"members":[],"members_summary":null}],"sector":{"regulator":{},"operators":{"structure":"many","note":"2,629 operator names (Utility Name) across 7,309 plants with operating PV in the 2025 file; 2,741 entity names across operating PV generators in the September 2026 file.","census_url":"https://www.eia.gov/electricity/data/eia860/"},"publication_obligation":{"exists":"no_evidence_found","norm":null,"url":null,"what_must_be_published":null,"frequency":null},"consolidated_republication":{"found":"partial","note":"USPVDB v4.0 republishes ground-mounted PV of 1 MW or more with EIA plant codes and polygons; 1,064 EIA PV plants of 1 MW or more are not in it. LBNL republishes EIA data above 5 MW AC with dates.","checked_pages":[{"organization":"U.S. Geological Survey / LBNL","url":"https://energy.usgs.gov/uspvdb/data/","saw":"Download page (HTTP 200) with CSV, shapefile and GeoJSON zips, XML metadata and the FeatureServer address."},{"organization":"Lawrence Berkeley National Laboratory","url":"https://eta-publications.lbl.gov/publications/us-utility-scale-solar-2026-edition","saw":"Utility-Scale Solar 2026 edition with a public XLSX data file of 1,989 PV projects."},{"organization":"Catalyst Cooperative (Zenodo archive)","url":"https://zenodo.org/records/14736300","saw":"Archive of USPVDB v2.0 raw inputs, read in pass 1; superseded."}]}},"national_registry":{"exists":"partial","note":"EIA-860 is the official national plant register for generators of 1 MW or more, including PV. No official national register of individual PV systems under 1 MW was found.","checked_pages":[{"organization":"U.S. Energy Information Administration","url":"https://www.eia.gov/electricity/data/eia860/","saw":"Final 2025 release on 10 September 2026; the form covers plants with 1 MW or more combined nameplate."},{"organization":"U.S. Energy Information Administration","url":"https://www.eia.gov/electricity/data/eia860m/","saw":"Monthly release dated 23 October 2026 (September inventory); next release 24 November 2026; Puerto Rico included since March 2018."},{"organization":"U.S. Geological Survey","url":"https://energy.usgs.gov/uspvdb/","saw":"USPVDB v4.0 of 14 April 2026: 6,611 facilities in 49 states and DC."},{"organization":"U.S. Energy Information Administration","url":"https://www.eia.gov/electricity/data/eia861m/","saw":"Form EIA-861M page: small-scale PV estimate and net metering files, from a sample of utilities; release of 23 October 2026."}]},"if_unstructured":{"summary":"Under 1 MW there is no official plant list. EIA publishes state estimates (Table 6.2.B: 63,193 MW in August 2026). LBNL's Tracking the Sun public file holds about 4.0 million systems with ZIP code, DC size and installation date but no operator; the file was not downloaded. State interconnection datasets were not checked.","recipe":["Download the CSV through the guide's link (a Google Drive file); keep state, zip_code, PV_system_size_DC and installation_date; treat -1 as missing.","Count systems under 1 MW per state and compare with EIA's state estimate, noting AC (EIA) against DC (LBNL).","For operators of small installations, check state interconnection or incentive datasets, which were not searched."],"location_method":"ZIP code from Tracking the Sun (guide read); no coordinates or addresses are published in the public file.","cross_with":["EIA Plant Code (utility-scale matches only)","state and ZIP code"],"where_published":[{"name":"EIA Electric Power Monthly, Table 6.2.B","url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","what":"Estimated small-scale PV capacity by state and for the U.S., monthly, from the EIA-861M utility sample.","how_to_search_inside":"Open the table and read the 'Estimated Solar Photovoltaic' column for the state.","example_document":{"url":"https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_6_02_b","what_it_gives":"U.S. Total small-scale PV 63,192.6 MW in August 2026."}},{"name":"LBNL Tracking the Sun user guide","url":"https://eta-publications.lbl.gov/sites/default/files/2026-08/lbnl_publicdatafile_userguide_8.07.26.pdf","what":"Field list (81 fields) and scope of the public file of distributed PV systems; links to the CSV.","how_to_search_inside":"Read the field table (installation_date, PV_system_size_DC, zip_code, state).","example_document":{"url":"https://eta-publications.lbl.gov/publications/us-distributed-solar-and-storage-0","what_it_gives":"Landing page: about 5.3 million systems through 2025."}}]},"related_not_answering":[{"name":"EIA-860 'Proposed' sheet (planned generators)","url":"https://www.eia.gov/electricity/data/eia860/","why":"Planned projects belong to the permitting topic, not to operating plants."},{"name":"EIA-860 'Retired and Canceled' sheets","url":"https://www.eia.gov/electricity/data/eia860/","why":"Retired or canceled generators are not operating."},{"name":"LBNL Utility-Scale Solar hourly generation and market value files","url":"https://data.openei.org/submissions/8783","why":"Modelled generation and value per plant (6.91 GB); not a plant list. Page read, files not downloaded."}],"open_questions":["Territory: United States, small-scale PV (under 1 MW). Continue from: download LBNL's Tracking the Sun CSV (Google Drive link in the user guide), count systems under 1 MW by state, and search state interconnection datasets for operators.","Territory: United States, USPVDB v4.0 coverage. Continue from: the 57 records that match no operating PV plant in EIA-860 2025 or EIA-860M September 2026 (38 are absent from the annual Operable sheet), and the 1,064 EIA PV plants of 1 MW or more that v4.0 does not map.","Territory: United States, USPVDB data release page. Continue from: ScienceBase (DOI 10.5066/P9IA3TUS), which still answers HTTP 403; the shapefile and GeoJSON zips were downloaded but not opened.","Territory: United States, location differences. Continue from: 213 of 6,553 matched plants lie more than 5 km from the EIA point; eia_id 61089 (Fisher Solar Farm-NC, 224.6 km), 69091 (Kirkland, NY, 161.7 km) and 65104 (CA, 333.5 km) need checking against the site and the image date.","Territory: United States, operator definition. Continue from: decide whether to publish 'Utility Name' or owners; the Ownership sheet lists 1,386 PV plants and 98 with several owners; EIA-860M 'Entity Name' differs from Utility Name for 190 generators.","Territory: United States, EIA-860M instructions. Continue from: the Form EIA-860M instructions, to confirm the AC basis and the Entity definition, which are only inferred from numerical matches."],"history":[{"pass":1,"date":"2026-11-19","role":"research","model":"claude-haiku-5-5","rules_version":"us-solar-flood-2026-11-19","note":"First pass. EIA-860 2025 and EIA-860M tested by download; USPVDB tested from a Zenodo archive; OSM tested in one box. USGS, LBNL and EIA API not usable here.","headline":{"official_data":"partial","non_official_data":"partial","national_registry":"partial"},"sources":{"total":4,"new":4,"dropped":0},"negatives":{"overturned":0,"confirmed":0},"effort":{"pages":21,"minutes":28}},{"pass":2,"date":"2026-11-19","role":"revision","model":"claude-sonnet-5-5","rules_version":"2026-11-19-eeuu-revision","note":"Revision. USGS now reachable: USPVDB v4.0 downloaded and its service queried. EIA-860 and EIA-860M figures reproduced; 860M scope and Puerto Rico documented; states corrected to 49 and DC. LBNL utility-scale file read; Tracking the Sun described, not downloaded.","headline":{"official_data":"partial","non_official_data":"partial","national_registry":"partial"},"sources":{"total":8,"new":4,"dropped":0},"negatives":{"overturned":2,"confirmed":1},"effort":{"pages":40,"minutes":25}}],"local_terms":[{"term":"Nameplate Capacity (MW)","language":"en","meaning":"EIA AC nameplate of a generator; for PV, the sum of AC ratings of the array."},{"term":"DC Net Capacity (MW)","language":"en","meaning":"Net DC capacity under STC (1000 W/m2, 25 °C); solar sheet only."},{"term":"Status OP","language":"en","meaning":"Operating – in service (commercial operation)."},{"term":"Utility Name","language":"en","meaning":"Company responsible for the day-to-day operations of the generator (EIA-860 layout)."},{"term":"Plant Code / eia_id","language":"en","meaning":"EIA plant identifier; USPVDB calls it eia_id, EIA-860M calls it Plant ID."},{"term":"Small-scale solar","language":"en","meaning":"PV systems under 1 MW, typically on rooftops; estimated by EIA, not listed per plant."},{"term":"Large-scale PV facility (USPVDB)","language":"en","meaning":"USPVDB scope: ground-mounted PV of 1 MW or more (threshold on DC)."},{"term":"Distributed solar (LBNL)","language":"en","meaning":"Rooftop systems and ground-mounted systems up to 5 MW AC or 7 MW DC, in Tracking the Sun."}],"provenance":{"pass_count":2,"models":["claude-haiku-5-5","claude-sonnet-5-5"],"minutes_estimate":53,"pages_opened":61,"passes":[{"pass":1,"date":"2026-11-19","model":"claude-haiku-5-5"},{"pass":2,"date":"2026-11-19","model":"claude-sonnet-5-5"}],"note":"Minutes are researcher estimates. Counts describe documented passes, not publication approval. Missing history or effort is not reconstructed."},"card_url":"https://georutter.org/v1/us/solar-pv-plants.json","detail_url":"https://georutter.org/v1/us/solar-pv-plants/detail.json","html_url":"https://georutter.org/us/solar-pv-plants/","country_url":"https://georutter.org/v1/countries/us.json"}
